Zhiyu Cao, Yewen Zhang, Cong Guo, F. Zheng, Z. An, S. Holé, Enke Yu, Xinlong Zheng, Zhien Zhu, Liming Yang
{"title":"基于激光PWP法的全尺寸高压直流长电缆空间电荷测量系统","authors":"Zhiyu Cao, Yewen Zhang, Cong Guo, F. Zheng, Z. An, S. Holé, Enke Yu, Xinlong Zheng, Zhien Zhu, Liming Yang","doi":"10.1109/CMD.2018.8535965","DOIUrl":null,"url":null,"abstract":"Because of the limitation of technical level and experimental conditions, the space charge distributions in the full-size HVDC cables has never been obtained by the laser PWP method. In this paper, a space charge test system was designed for the space charge measurement of the full-size long cable. To verify the capabilities of the system, space charge distributions in full-size 10m long cable with 15mm thick insulation were measured, while the voltage range was setting from +50kV to +200kV. Then the space charge injection experiment is carried out, and the applied voltage is maintained +200kV, which lasted for 48 hours and the space charge injection data are obtained.","PeriodicalId":6529,"journal":{"name":"2018 Condition Monitoring and Diagnosis (CMD)","volume":"21 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Space Charge Measurement System Based on Laser PWP Method for the Full-size Long HVDC Cable\",\"authors\":\"Zhiyu Cao, Yewen Zhang, Cong Guo, F. Zheng, Z. An, S. Holé, Enke Yu, Xinlong Zheng, Zhien Zhu, Liming Yang\",\"doi\":\"10.1109/CMD.2018.8535965\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Because of the limitation of technical level and experimental conditions, the space charge distributions in the full-size HVDC cables has never been obtained by the laser PWP method. In this paper, a space charge test system was designed for the space charge measurement of the full-size long cable. To verify the capabilities of the system, space charge distributions in full-size 10m long cable with 15mm thick insulation were measured, while the voltage range was setting from +50kV to +200kV. Then the space charge injection experiment is carried out, and the applied voltage is maintained +200kV, which lasted for 48 hours and the space charge injection data are obtained.\",\"PeriodicalId\":6529,\"journal\":{\"name\":\"2018 Condition Monitoring and Diagnosis (CMD)\",\"volume\":\"21 1\",\"pages\":\"1-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 Condition Monitoring and Diagnosis (CMD)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CMD.2018.8535965\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 Condition Monitoring and Diagnosis (CMD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CMD.2018.8535965","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Space Charge Measurement System Based on Laser PWP Method for the Full-size Long HVDC Cable
Because of the limitation of technical level and experimental conditions, the space charge distributions in the full-size HVDC cables has never been obtained by the laser PWP method. In this paper, a space charge test system was designed for the space charge measurement of the full-size long cable. To verify the capabilities of the system, space charge distributions in full-size 10m long cable with 15mm thick insulation were measured, while the voltage range was setting from +50kV to +200kV. Then the space charge injection experiment is carried out, and the applied voltage is maintained +200kV, which lasted for 48 hours and the space charge injection data are obtained.