{"title":"列格纳罗国家实验室XTU串联柱梯试验","authors":"F. Cervellera, C. Signorini","doi":"10.1016/0029-554X(81)90847-8","DOIUrl":null,"url":null,"abstract":"<div><p>The column structure of the XTU tandem Van de Graaff generator at Legnaro has been successfully tested up to 20.3 MV in +7.3 bar SF<sub>6</sub> gas. The laddertron charging system adopted has been able to deliver up to 400 μA charging current per chain.</p></div>","PeriodicalId":100971,"journal":{"name":"Nuclear Instruments and Methods","volume":"184 1","pages":"Pages 49-54"},"PeriodicalIF":0.0000,"publicationDate":"1981-05-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0029-554X(81)90847-8","citationCount":"2","resultStr":"{\"title\":\"Column and laddertron tests at the XTU tandem of the laboratori nazionali di Legnaro\",\"authors\":\"F. Cervellera, C. Signorini\",\"doi\":\"10.1016/0029-554X(81)90847-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The column structure of the XTU tandem Van de Graaff generator at Legnaro has been successfully tested up to 20.3 MV in +7.3 bar SF<sub>6</sub> gas. The laddertron charging system adopted has been able to deliver up to 400 μA charging current per chain.</p></div>\",\"PeriodicalId\":100971,\"journal\":{\"name\":\"Nuclear Instruments and Methods\",\"volume\":\"184 1\",\"pages\":\"Pages 49-54\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1981-05-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/0029-554X(81)90847-8\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nuclear Instruments and Methods\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/0029554X81908478\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Instruments and Methods","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0029554X81908478","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
摘要
在Legnaro的XTU串联Van de Graaff发生器的柱结构已经成功地在+7.3 bar的SF6气体中进行了高达20.3 MV的测试。所采用的阶梯充电系统每条链的充电电流可达400 μA。
Column and laddertron tests at the XTU tandem of the laboratori nazionali di Legnaro
The column structure of the XTU tandem Van de Graaff generator at Legnaro has been successfully tested up to 20.3 MV in +7.3 bar SF6 gas. The laddertron charging system adopted has been able to deliver up to 400 μA charging current per chain.