基于量子点的荧光免疫层析法分析猪饲料、肌肉和肝脏样品中的维吉尼霉素M1

Jingming Zhou, Wenjing Qian, Qingbao Yang, Chao Liang, Yumei Chen, Aiping Wang, Gaiping Zhang
{"title":"基于量子点的荧光免疫层析法分析猪饲料、肌肉和肝脏样品中的维吉尼霉素M1","authors":"Jingming Zhou, Wenjing Qian, Qingbao Yang, Chao Liang, Yumei Chen, Aiping Wang, Gaiping Zhang","doi":"10.1080/19440049.2022.2081366","DOIUrl":null,"url":null,"abstract":"Abstract Based on a highly sensitive and specific monoclonal antibody (mAb) against virginiamycin M1 (VIR M1), a quantum dots-based fluorescent immunochromatographic assay (QDs-ICA) for quick and sensitive analysis of VIR M1 was established for the first time. The mAb showed a half-maximal inhibitory concentration (IC50) of 0.5 ng/mL and cross-reactivity (CR) values below 0.1% for other three analogues when used in enzyme-linked immunosorbent assay (ELISA). The mAb was conjugated to ZnCdSe/ZnS (core/shell) QDs with maximum emission wavelength of 610 nm (orange-red) which was selected as fluorescent probe to increase QDs-ICA sensitivity. The cut-off value of QDs-ICA was 12.5 ng/mL. QDs-ICA showed a linear range from 0.7 to 14.5 ng/mL with a limit of quantification of 0.7 ng/mL. Compared with existing methods for the analysis of VIR M1, the QDs-ICA exhibited higher sensitivity. For analysis of VIR M1 concentrations spiked into swine feed, muscle and liver samples, recovery rates ranged from 94.0% to 111.6% with the highest coefficient of variation (CV) of 6.7% for intra-assay, and for inter-assay ranged from 94.7% to 107.6% with the highest CV of 9.4%. In conclusion, the QDs-ICA could be a potential method for analyzing VIR M1 in animal feed and animal-derived food.","PeriodicalId":12121,"journal":{"name":"Food Additives & Contaminants: Part A","volume":"2013 1","pages":"1390 - 1400"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Analysis of virginiamycin M1 in swine feed, muscle and liver samples by quantum dots-based fluorescent immunochromatographic assay\",\"authors\":\"Jingming Zhou, Wenjing Qian, Qingbao Yang, Chao Liang, Yumei Chen, Aiping Wang, Gaiping Zhang\",\"doi\":\"10.1080/19440049.2022.2081366\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Based on a highly sensitive and specific monoclonal antibody (mAb) against virginiamycin M1 (VIR M1), a quantum dots-based fluorescent immunochromatographic assay (QDs-ICA) for quick and sensitive analysis of VIR M1 was established for the first time. The mAb showed a half-maximal inhibitory concentration (IC50) of 0.5 ng/mL and cross-reactivity (CR) values below 0.1% for other three analogues when used in enzyme-linked immunosorbent assay (ELISA). The mAb was conjugated to ZnCdSe/ZnS (core/shell) QDs with maximum emission wavelength of 610 nm (orange-red) which was selected as fluorescent probe to increase QDs-ICA sensitivity. The cut-off value of QDs-ICA was 12.5 ng/mL. QDs-ICA showed a linear range from 0.7 to 14.5 ng/mL with a limit of quantification of 0.7 ng/mL. Compared with existing methods for the analysis of VIR M1, the QDs-ICA exhibited higher sensitivity. For analysis of VIR M1 concentrations spiked into swine feed, muscle and liver samples, recovery rates ranged from 94.0% to 111.6% with the highest coefficient of variation (CV) of 6.7% for intra-assay, and for inter-assay ranged from 94.7% to 107.6% with the highest CV of 9.4%. In conclusion, the QDs-ICA could be a potential method for analyzing VIR M1 in animal feed and animal-derived food.\",\"PeriodicalId\":12121,\"journal\":{\"name\":\"Food Additives & Contaminants: Part A\",\"volume\":\"2013 1\",\"pages\":\"1390 - 1400\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-06-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Food Additives & Contaminants: Part A\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/19440049.2022.2081366\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Food Additives & Contaminants: Part A","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/19440049.2022.2081366","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

基于virginiamycin M1 (VIR M1)高敏感特异性单克隆抗体(mAb),首次建立了基于量子点的VIR M1荧光免疫层析(QDs-ICA)快速、灵敏分析方法。当用于酶联免疫吸附试验(ELISA)时,该单抗对其他三种类似物的半最大抑制浓度(IC50)为0.5 ng/mL,交叉反应性(CR)值低于0.1%。该单抗与ZnCdSe/ZnS(核/壳)量子点偶联,最大发射波长为610 nm(橙红色),作为荧光探针,以提高QDs- ica灵敏度。QDs-ICA的截止值为12.5 ng/mL。QDs-ICA在0.7 ~ 14.5 ng/mL范围内呈线性关系,定量限为0.7 ng/mL。与现有的VIR M1分析方法相比,QDs-ICA具有更高的灵敏度。对猪饲料、肌肉和肝脏样品中添加的VIR M1浓度进行分析,检测内回收率为94.0% ~ 111.6%,变异系数(CV)最高为6.7%;检测间回收率为94.7% ~ 107.6%,变异系数最高为9.4%。综上所述,QDs-ICA可作为分析动物饲料和动物源性食品中VIR M1的一种潜在方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Analysis of virginiamycin M1 in swine feed, muscle and liver samples by quantum dots-based fluorescent immunochromatographic assay
Abstract Based on a highly sensitive and specific monoclonal antibody (mAb) against virginiamycin M1 (VIR M1), a quantum dots-based fluorescent immunochromatographic assay (QDs-ICA) for quick and sensitive analysis of VIR M1 was established for the first time. The mAb showed a half-maximal inhibitory concentration (IC50) of 0.5 ng/mL and cross-reactivity (CR) values below 0.1% for other three analogues when used in enzyme-linked immunosorbent assay (ELISA). The mAb was conjugated to ZnCdSe/ZnS (core/shell) QDs with maximum emission wavelength of 610 nm (orange-red) which was selected as fluorescent probe to increase QDs-ICA sensitivity. The cut-off value of QDs-ICA was 12.5 ng/mL. QDs-ICA showed a linear range from 0.7 to 14.5 ng/mL with a limit of quantification of 0.7 ng/mL. Compared with existing methods for the analysis of VIR M1, the QDs-ICA exhibited higher sensitivity. For analysis of VIR M1 concentrations spiked into swine feed, muscle and liver samples, recovery rates ranged from 94.0% to 111.6% with the highest coefficient of variation (CV) of 6.7% for intra-assay, and for inter-assay ranged from 94.7% to 107.6% with the highest CV of 9.4%. In conclusion, the QDs-ICA could be a potential method for analyzing VIR M1 in animal feed and animal-derived food.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信