{"title":"H. abdul moeloek bandar lampung医生医院延迟4小时后使用k2edta抗凝剂的3ml、2ml和1ml血液样本中红细胞数量的比较","authors":"Syuhada, Hemas Priyayi, Bella Tania Putri, Zehan Aura Nabigha, Tusy Triwahyuni","doi":"10.55047/comorbid.v1i2.144","DOIUrl":null,"url":null,"abstract":"Background: The volume of blood samples, especially the number of erythrocytes in laboratory examinations, has an important role in determining the results of the diagnosis, in this case pre-analytic errors often occur so that a definite diagnosis will be difficult to establish. Therefore, research on the comparison between the results of the examination of the number of erythrocytes in the volume of blood samples of 3 mL, 2 mL, and 1 mL after being delayed for 4 hours with K2EDTA anticoagulant helps to determine a definite diagnosis from laboratory tests, one of which is the count of the number of erythrocytes. Research purpose: it aims to identify the comparison of erythrocytes in the volume of blood sample 3 ml, 2 ml, and 1 ml with k2edta anticoagulant after postponed for four hours. Research methods: the study uses primary data with hematology analyzer in rsud Dr.abdul moeloek bandar lampung. This type of research is a quantitative, using observational analtic design with a cross sectional view and with consecutive method, through hematology analysis using a alayzer mindray bc-3600 hematology. The research has 50 respondents. Results: the results of erythrocytes comparison between blood volume 3 ml, 2 ml and 1 ml (ml) with k2edta anticoagulant after 4 hours have different results but statistically the results have the same with 3 ml, that show the lowest result. Conclusion: there is no significant differences between the examunation of the erythrocytes with the volume of blood sample 3 mL, 2 mL, and 1 mL in the vacutainer k2edta tube after postponed for four hours.","PeriodicalId":19772,"journal":{"name":"PHARMACOLOGY, MEDICAL REPORTS, ORTHOPEDIC, AND ILLNESS DETAILS (COMORBID)","volume":"16 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-03-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"COMPARISON OF THE NUMBER OF ERYTHROCYTES IN 3 ML, 2 ML, & 1 ML OF BLOOD SAMPLES WITH K2EDTA ANTICOAGULANTS AFTER A 4-HOUR DELAY IN THE DR. H. ABDUL MOELOEK BANDAR LAMPUNG HOSPITAL\",\"authors\":\"Syuhada, Hemas Priyayi, Bella Tania Putri, Zehan Aura Nabigha, Tusy Triwahyuni\",\"doi\":\"10.55047/comorbid.v1i2.144\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: The volume of blood samples, especially the number of erythrocytes in laboratory examinations, has an important role in determining the results of the diagnosis, in this case pre-analytic errors often occur so that a definite diagnosis will be difficult to establish. Therefore, research on the comparison between the results of the examination of the number of erythrocytes in the volume of blood samples of 3 mL, 2 mL, and 1 mL after being delayed for 4 hours with K2EDTA anticoagulant helps to determine a definite diagnosis from laboratory tests, one of which is the count of the number of erythrocytes. Research purpose: it aims to identify the comparison of erythrocytes in the volume of blood sample 3 ml, 2 ml, and 1 ml with k2edta anticoagulant after postponed for four hours. Research methods: the study uses primary data with hematology analyzer in rsud Dr.abdul moeloek bandar lampung. This type of research is a quantitative, using observational analtic design with a cross sectional view and with consecutive method, through hematology analysis using a alayzer mindray bc-3600 hematology. The research has 50 respondents. Results: the results of erythrocytes comparison between blood volume 3 ml, 2 ml and 1 ml (ml) with k2edta anticoagulant after 4 hours have different results but statistically the results have the same with 3 ml, that show the lowest result. Conclusion: there is no significant differences between the examunation of the erythrocytes with the volume of blood sample 3 mL, 2 mL, and 1 mL in the vacutainer k2edta tube after postponed for four hours.\",\"PeriodicalId\":19772,\"journal\":{\"name\":\"PHARMACOLOGY, MEDICAL REPORTS, ORTHOPEDIC, AND ILLNESS DETAILS (COMORBID)\",\"volume\":\"16 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-03-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"PHARMACOLOGY, MEDICAL REPORTS, ORTHOPEDIC, AND ILLNESS DETAILS (COMORBID)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.55047/comorbid.v1i2.144\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"PHARMACOLOGY, MEDICAL REPORTS, ORTHOPEDIC, AND ILLNESS DETAILS (COMORBID)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.55047/comorbid.v1i2.144","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
背景:血液样本量,特别是实验室检查中红细胞的数量,在确定诊断结果中起着重要的作用,在这种情况下,经常发生分析前错误,因此难以建立明确的诊断。因此,研究延迟使用K2EDTA抗凝4小时后3ml、2ml和1ml血标本体积中红细胞数量的检测结果对比,有助于从实验室检查中确定明确的诊断,其中之一就是红细胞计数。研究目的:确定k2edta抗凝药延迟4小时后血样本量3ml、2ml、1ml中红细胞的比较。研究方法:本研究使用了abdul moeloek bandar lampung博士的血液分析仪的原始数据。这种类型的研究是定量的,采用观察分析设计与横断面视图和连续方法,通过血液学分析使用迈瑞bc-3600血液学分析仪。该调查共有50名受访者。结果:k2edta抗凝4 h后血容量3ml、2ml、1ml的红细胞比较结果有差异,与3ml的结果有统计学意义相同,均为最低结果。结论:k2edta管中血样量为3ml、2ml和1ml的红细胞延迟4小时后的检测无明显差异。
COMPARISON OF THE NUMBER OF ERYTHROCYTES IN 3 ML, 2 ML, & 1 ML OF BLOOD SAMPLES WITH K2EDTA ANTICOAGULANTS AFTER A 4-HOUR DELAY IN THE DR. H. ABDUL MOELOEK BANDAR LAMPUNG HOSPITAL
Background: The volume of blood samples, especially the number of erythrocytes in laboratory examinations, has an important role in determining the results of the diagnosis, in this case pre-analytic errors often occur so that a definite diagnosis will be difficult to establish. Therefore, research on the comparison between the results of the examination of the number of erythrocytes in the volume of blood samples of 3 mL, 2 mL, and 1 mL after being delayed for 4 hours with K2EDTA anticoagulant helps to determine a definite diagnosis from laboratory tests, one of which is the count of the number of erythrocytes. Research purpose: it aims to identify the comparison of erythrocytes in the volume of blood sample 3 ml, 2 ml, and 1 ml with k2edta anticoagulant after postponed for four hours. Research methods: the study uses primary data with hematology analyzer in rsud Dr.abdul moeloek bandar lampung. This type of research is a quantitative, using observational analtic design with a cross sectional view and with consecutive method, through hematology analysis using a alayzer mindray bc-3600 hematology. The research has 50 respondents. Results: the results of erythrocytes comparison between blood volume 3 ml, 2 ml and 1 ml (ml) with k2edta anticoagulant after 4 hours have different results but statistically the results have the same with 3 ml, that show the lowest result. Conclusion: there is no significant differences between the examunation of the erythrocytes with the volume of blood sample 3 mL, 2 mL, and 1 mL in the vacutainer k2edta tube after postponed for four hours.