{"title":"一种用于心电信号快速跟踪和消除电力线干扰的智能自适应滤波器","authors":"N. Razzaq, M. Butt, M. Salman, Rahat Ali, I. Sadiq, K. Munawar, T. Zaidi","doi":"10.1109/CBMS.2013.6627797","DOIUrl":null,"url":null,"abstract":"The ECG (Electrocardiogram) signal reflects the electrical activity of the heart. Since amplitude of ECG signal is of order of few mV, it is susceptible to many types of noises and amongst which the most disturbing is power line interference (PLI). Variations in frequency of PLI further complicate the problem which can be taken care by implementation of adaptive notch filter (ANF). ANF normally requires a reference input which is not possible in all cases. In this paper, we have proposed an intelligent adaptive filter which does not require a reference input. Proposed method first detects the frequency of PLI noise then adaptively tracks and eliminates PLI from ECG signal.","PeriodicalId":20519,"journal":{"name":"Proceedings of the 26th IEEE International Symposium on Computer-Based Medical Systems","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2013-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"An intelligent adaptive filter for fast tracking and elimination of power line interference from ECG signal\",\"authors\":\"N. Razzaq, M. Butt, M. Salman, Rahat Ali, I. Sadiq, K. Munawar, T. Zaidi\",\"doi\":\"10.1109/CBMS.2013.6627797\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The ECG (Electrocardiogram) signal reflects the electrical activity of the heart. Since amplitude of ECG signal is of order of few mV, it is susceptible to many types of noises and amongst which the most disturbing is power line interference (PLI). Variations in frequency of PLI further complicate the problem which can be taken care by implementation of adaptive notch filter (ANF). ANF normally requires a reference input which is not possible in all cases. In this paper, we have proposed an intelligent adaptive filter which does not require a reference input. Proposed method first detects the frequency of PLI noise then adaptively tracks and eliminates PLI from ECG signal.\",\"PeriodicalId\":20519,\"journal\":{\"name\":\"Proceedings of the 26th IEEE International Symposium on Computer-Based Medical Systems\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-06-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 26th IEEE International Symposium on Computer-Based Medical Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CBMS.2013.6627797\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 26th IEEE International Symposium on Computer-Based Medical Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CBMS.2013.6627797","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

心电图信号反映心脏的电活动。由于心电信号的幅值只有几个毫伏量级,它容易受到多种噪声的影响,其中最受干扰的是电力线干扰。PLI频率的变化使问题进一步复杂化,可以通过实现自适应陷波滤波器(ANF)来解决。ANF通常需要一个参考输入,这在所有情况下都是不可能的。本文提出了一种不需要参考输入的智能自适应滤波器。该方法首先检测出PLI噪声的频率,然后自适应跟踪并消除心电信号中的PLI。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An intelligent adaptive filter for fast tracking and elimination of power line interference from ECG signal
The ECG (Electrocardiogram) signal reflects the electrical activity of the heart. Since amplitude of ECG signal is of order of few mV, it is susceptible to many types of noises and amongst which the most disturbing is power line interference (PLI). Variations in frequency of PLI further complicate the problem which can be taken care by implementation of adaptive notch filter (ANF). ANF normally requires a reference input which is not possible in all cases. In this paper, we have proposed an intelligent adaptive filter which does not require a reference input. Proposed method first detects the frequency of PLI noise then adaptively tracks and eliminates PLI from ECG signal.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.10
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信