mbr内、外污染对跨膜压力的影响:实验与模拟

Meng Hu, Tian C. Zhang, J. Stansbury, You Zhou, Han Chen, J. Neal
{"title":"mbr内、外污染对跨膜压力的影响:实验与模拟","authors":"Meng Hu, Tian C. Zhang, J. Stansbury, You Zhou, Han Chen, J. Neal","doi":"10.1061/(ASCE)EE.1943-7870.0000925","DOIUrl":null,"url":null,"abstract":"AbstractThis paper reports a new approach to understanding membrane fouling in membrane bioreactors (MBR). The foulants were categorized into those inside the membrane (internal fouling) and those on the membrane forming the so-called external fouling layer (external fouling). The volumes of the internal and external foulants were determined with the aid of a confocal laser scanning microscope (CLSM) after staining the foulants. Thus, the porosities of both the membrane and the external fouling layer were calculated, which explained the contributions of internal and external fouling to transmembrane pressure (TMP) from the standpoint of fundamental filtration theory. The categorical method indicates that external fouling may dominate the long-term operation of MBR with the formation of the external fouling layer, whereas internal fouling, in the form of pore constriction, may cause both initial and final TMP jumps under the operating conditions in the current study. In addition, a mathematical model was d...","PeriodicalId":17335,"journal":{"name":"Journal of the Environmental Engineering Division","volume":"102 1","pages":"4014097"},"PeriodicalIF":0.0000,"publicationDate":"2015-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Contributions of Internal and External Fouling to Transmembrane Pressure in MBRs: Experiments and Modeling\",\"authors\":\"Meng Hu, Tian C. Zhang, J. Stansbury, You Zhou, Han Chen, J. Neal\",\"doi\":\"10.1061/(ASCE)EE.1943-7870.0000925\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"AbstractThis paper reports a new approach to understanding membrane fouling in membrane bioreactors (MBR). The foulants were categorized into those inside the membrane (internal fouling) and those on the membrane forming the so-called external fouling layer (external fouling). The volumes of the internal and external foulants were determined with the aid of a confocal laser scanning microscope (CLSM) after staining the foulants. Thus, the porosities of both the membrane and the external fouling layer were calculated, which explained the contributions of internal and external fouling to transmembrane pressure (TMP) from the standpoint of fundamental filtration theory. The categorical method indicates that external fouling may dominate the long-term operation of MBR with the formation of the external fouling layer, whereas internal fouling, in the form of pore constriction, may cause both initial and final TMP jumps under the operating conditions in the current study. In addition, a mathematical model was d...\",\"PeriodicalId\":17335,\"journal\":{\"name\":\"Journal of the Environmental Engineering Division\",\"volume\":\"102 1\",\"pages\":\"4014097\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Environmental Engineering Division\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1061/(ASCE)EE.1943-7870.0000925\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Environmental Engineering Division","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1061/(ASCE)EE.1943-7870.0000925","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

摘要本文报道了一种了解膜生物反应器(MBR)中膜污染的新方法。将污染分为膜内污染(内部污染)和膜外污染(外部污染)。染色后用共聚焦激光扫描显微镜(CLSM)测定内、外杂质的体积。因此,计算了膜层和外污染层的孔隙率,从基本过滤理论的角度解释了内外污染对跨膜压力(TMP)的贡献。分类方法表明,在本研究的运行条件下,外部污染可能会随着外部污染层的形成而主导MBR的长期运行,而内部污染以孔隙收缩的形式可能会导致初始和最终TMP跳变。此外,还建立了数学模型。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Contributions of Internal and External Fouling to Transmembrane Pressure in MBRs: Experiments and Modeling
AbstractThis paper reports a new approach to understanding membrane fouling in membrane bioreactors (MBR). The foulants were categorized into those inside the membrane (internal fouling) and those on the membrane forming the so-called external fouling layer (external fouling). The volumes of the internal and external foulants were determined with the aid of a confocal laser scanning microscope (CLSM) after staining the foulants. Thus, the porosities of both the membrane and the external fouling layer were calculated, which explained the contributions of internal and external fouling to transmembrane pressure (TMP) from the standpoint of fundamental filtration theory. The categorical method indicates that external fouling may dominate the long-term operation of MBR with the formation of the external fouling layer, whereas internal fouling, in the form of pore constriction, may cause both initial and final TMP jumps under the operating conditions in the current study. In addition, a mathematical model was d...
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信