用OCT精确测量散射介质中总衰减系数的双焦点技术

A. Kholodnykh, I. Petrova, M. Motamedi, R. Esenaliev
{"title":"用OCT精确测量散射介质中总衰减系数的双焦点技术","authors":"A. Kholodnykh, I. Petrova, M. Motamedi, R. Esenaliev","doi":"10.1109/IEMBS.2002.1053267","DOIUrl":null,"url":null,"abstract":"Accurate measurements of tissue optical properties are needed for many diagnostic and therapeutic applications of optical techniques. OCT recently proposed for high-resolution imaging in tissue can potentially be applied for accurate and noninvasive measurement of tissue optical properties. We proposed a bifocal technique for accurate measurement of tissue total attenuation coefficient with OCT. This technique utilizes detection of OCT signals from two focal planes within scattering media that allows correction for confocal function. In this paper, we studied the capability of the bifocal technique to measure accurately total attenuation coefficient in scattering media simulating tissue with high and low scattering. The experiments were performed with tissue phantoms: suspension of polystyrene microspheres in water with different total attenuation coefficients. Our studies demonstrated that the bifocal technique substantially improves accuracy of measurement: absolute values of total attenuation coefficient can be measured with 7% accuracy (compared with theoretically calculated values), while the accuracy of relative measurements can be 1.5%. Our results indicate that the bifocal technique is a promising approach to accurate measurement of total attenuation coefficient in tissues.","PeriodicalId":60385,"journal":{"name":"中国地球物理学会年刊","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2002-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Bifocal technique for accurate measurement of total attenuation coefficient in scattering media with OCT\",\"authors\":\"A. Kholodnykh, I. Petrova, M. Motamedi, R. Esenaliev\",\"doi\":\"10.1109/IEMBS.2002.1053267\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Accurate measurements of tissue optical properties are needed for many diagnostic and therapeutic applications of optical techniques. OCT recently proposed for high-resolution imaging in tissue can potentially be applied for accurate and noninvasive measurement of tissue optical properties. We proposed a bifocal technique for accurate measurement of tissue total attenuation coefficient with OCT. This technique utilizes detection of OCT signals from two focal planes within scattering media that allows correction for confocal function. In this paper, we studied the capability of the bifocal technique to measure accurately total attenuation coefficient in scattering media simulating tissue with high and low scattering. The experiments were performed with tissue phantoms: suspension of polystyrene microspheres in water with different total attenuation coefficients. Our studies demonstrated that the bifocal technique substantially improves accuracy of measurement: absolute values of total attenuation coefficient can be measured with 7% accuracy (compared with theoretically calculated values), while the accuracy of relative measurements can be 1.5%. Our results indicate that the bifocal technique is a promising approach to accurate measurement of total attenuation coefficient in tissues.\",\"PeriodicalId\":60385,\"journal\":{\"name\":\"中国地球物理学会年刊\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"中国地球物理学会年刊\",\"FirstCategoryId\":\"1089\",\"ListUrlMain\":\"https://doi.org/10.1109/IEMBS.2002.1053267\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"中国地球物理学会年刊","FirstCategoryId":"1089","ListUrlMain":"https://doi.org/10.1109/IEMBS.2002.1053267","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

光学技术的许多诊断和治疗应用需要精确测量组织光学特性。最近提出的用于组织高分辨率成像的OCT可以潜在地应用于组织光学特性的精确和无创测量。我们提出了一种双聚焦技术,用于用OCT精确测量组织总衰减系数。该技术利用散射介质中来自两个焦平面的OCT信号检测,允许对共聚焦功能进行校正。本文研究了双焦点技术在模拟高散射和低散射组织的散射介质中精确测量总衰减系数的能力。实验采用不同总衰减系数的聚苯乙烯微球悬浮在水中的组织模型。我们的研究表明,双焦点技术大大提高了测量精度:总衰减系数绝对值的测量精度为7%(与理论计算值相比),相对测量精度为1.5%。我们的结果表明,双焦点技术是一种很有前途的方法来精确测量组织中的总衰减系数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Bifocal technique for accurate measurement of total attenuation coefficient in scattering media with OCT
Accurate measurements of tissue optical properties are needed for many diagnostic and therapeutic applications of optical techniques. OCT recently proposed for high-resolution imaging in tissue can potentially be applied for accurate and noninvasive measurement of tissue optical properties. We proposed a bifocal technique for accurate measurement of tissue total attenuation coefficient with OCT. This technique utilizes detection of OCT signals from two focal planes within scattering media that allows correction for confocal function. In this paper, we studied the capability of the bifocal technique to measure accurately total attenuation coefficient in scattering media simulating tissue with high and low scattering. The experiments were performed with tissue phantoms: suspension of polystyrene microspheres in water with different total attenuation coefficients. Our studies demonstrated that the bifocal technique substantially improves accuracy of measurement: absolute values of total attenuation coefficient can be measured with 7% accuracy (compared with theoretically calculated values), while the accuracy of relative measurements can be 1.5%. Our results indicate that the bifocal technique is a promising approach to accurate measurement of total attenuation coefficient in tissues.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
368
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信