{"title":"一种无创血压监测系统","authors":"S. Balamurugan, Ramasubba Reddy, S. Muthan","doi":"10.1109/RTEICT.2016.7808188","DOIUrl":null,"url":null,"abstract":"Blood pressure measurement serves as a pivot for diagnosis of cardiovascular conditions and is done conventionally using sphygmomanometer. However this method has the limitations of producing only fewer readings in a given time and causing patient discomfort. Hence there is a need for blood pressure measurement procedure that can give more readings in a given span of time and with utmost ease. We developed a low cost noninvasive blood pressure measurement system which uses the photoplethysmography technique. Reflective Infrared sensors are used for the developed module. The time difference between the blood flow in vein is used to find blood flow velocity, which is eventually used to compute the Systolic blood pressure.","PeriodicalId":6527,"journal":{"name":"2016 IEEE International Conference on Recent Trends in Electronics, Information & Communication Technology (RTEICT)","volume":"210 1","pages":"1999-2001"},"PeriodicalIF":0.0000,"publicationDate":"2016-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A noninvasive blood pressure monitoring system\",\"authors\":\"S. Balamurugan, Ramasubba Reddy, S. Muthan\",\"doi\":\"10.1109/RTEICT.2016.7808188\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Blood pressure measurement serves as a pivot for diagnosis of cardiovascular conditions and is done conventionally using sphygmomanometer. However this method has the limitations of producing only fewer readings in a given time and causing patient discomfort. Hence there is a need for blood pressure measurement procedure that can give more readings in a given span of time and with utmost ease. We developed a low cost noninvasive blood pressure measurement system which uses the photoplethysmography technique. Reflective Infrared sensors are used for the developed module. The time difference between the blood flow in vein is used to find blood flow velocity, which is eventually used to compute the Systolic blood pressure.\",\"PeriodicalId\":6527,\"journal\":{\"name\":\"2016 IEEE International Conference on Recent Trends in Electronics, Information & Communication Technology (RTEICT)\",\"volume\":\"210 1\",\"pages\":\"1999-2001\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-05-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE International Conference on Recent Trends in Electronics, Information & Communication Technology (RTEICT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/RTEICT.2016.7808188\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE International Conference on Recent Trends in Electronics, Information & Communication Technology (RTEICT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RTEICT.2016.7808188","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Blood pressure measurement serves as a pivot for diagnosis of cardiovascular conditions and is done conventionally using sphygmomanometer. However this method has the limitations of producing only fewer readings in a given time and causing patient discomfort. Hence there is a need for blood pressure measurement procedure that can give more readings in a given span of time and with utmost ease. We developed a low cost noninvasive blood pressure measurement system which uses the photoplethysmography technique. Reflective Infrared sensors are used for the developed module. The time difference between the blood flow in vein is used to find blood flow velocity, which is eventually used to compute the Systolic blood pressure.