基于PLC的工业电力系统智能功率因数校正器——一个案例研究

Naveenkumar R. Kulkami, H. Murthy, A. P. Raju
{"title":"基于PLC的工业电力系统智能功率因数校正器——一个案例研究","authors":"Naveenkumar R. Kulkami, H. Murthy, A. P. Raju","doi":"10.1109/ICPACE.2015.7274920","DOIUrl":null,"url":null,"abstract":"In recent years, the quality of power supplied to the consumer devices by an ac system has become an issue of great concern due to the rapidly increasing inductive loads, electronic equipments, power electronic devices and high system voltage. Power factor correction (PFC) is a technique of minimizing the undesirable effects of electric loads that create poor power factor conditions. Correction of power factor may be effected either by transmission utility which improves the stability and efficiency of the transmission network or by individuals customers. This paper aims at the correction method using an intelligent power factor corrector based on PLC (Programmable Logic Controller) as a control system especially for the correction of the industrial power factor, which is not only required for the smooth operation of the electrical equipments used in the industries but also to minimize the cost of penalty that has to be paid to power supply utilities for having low power factor. This involves measuring the power factor value from the supply line using Power Meter and development of a PLC program to determine and trigger capacitor banks of required rating in order to compensate deficient reactive power, thus bringing power factor near to unity. The results of this paper is based on the case study on application of the proposed method in a real industrial facility.","PeriodicalId":6644,"journal":{"name":"2015 International Conference on Power and Advanced Control Engineering (ICPACE)","volume":"52 1","pages":"75-79"},"PeriodicalIF":0.0000,"publicationDate":"2015-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"PLC based intelligent power factor correctors for industrial power systems-A case study\",\"authors\":\"Naveenkumar R. Kulkami, H. Murthy, A. P. Raju\",\"doi\":\"10.1109/ICPACE.2015.7274920\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In recent years, the quality of power supplied to the consumer devices by an ac system has become an issue of great concern due to the rapidly increasing inductive loads, electronic equipments, power electronic devices and high system voltage. Power factor correction (PFC) is a technique of minimizing the undesirable effects of electric loads that create poor power factor conditions. Correction of power factor may be effected either by transmission utility which improves the stability and efficiency of the transmission network or by individuals customers. This paper aims at the correction method using an intelligent power factor corrector based on PLC (Programmable Logic Controller) as a control system especially for the correction of the industrial power factor, which is not only required for the smooth operation of the electrical equipments used in the industries but also to minimize the cost of penalty that has to be paid to power supply utilities for having low power factor. This involves measuring the power factor value from the supply line using Power Meter and development of a PLC program to determine and trigger capacitor banks of required rating in order to compensate deficient reactive power, thus bringing power factor near to unity. The results of this paper is based on the case study on application of the proposed method in a real industrial facility.\",\"PeriodicalId\":6644,\"journal\":{\"name\":\"2015 International Conference on Power and Advanced Control Engineering (ICPACE)\",\"volume\":\"52 1\",\"pages\":\"75-79\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-09-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Conference on Power and Advanced Control Engineering (ICPACE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPACE.2015.7274920\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Power and Advanced Control Engineering (ICPACE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPACE.2015.7274920","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

近年来,由于电感负载、电子设备、电力电子设备和高系统电压的迅速增加,交流系统向消费设备供电的质量问题引起了人们的高度关注。功率因数校正(PFC)是一种尽量减少产生不良功率因数条件的电力负载的不良影响的技术。功率因数的修正既可以由提高输电网稳定性和效率的输电公用事业公司来实现,也可以由个人用户来实现。本文研究了一种基于PLC(可编程控制器)的智能功率因数校正器作为一种特别适用于工业功率因数校正的控制系统的校正方法,既能保证工业用电设备的正常运行,又能最大限度地减少因功率因数过低而给供电企业带来的损失。这包括使用功率计测量来自供电线路的功率因数值,并开发PLC程序来确定和触发所需额定值的电容器组,以补偿不足的无功功率,从而使功率因数接近统一。本文的结果是基于对该方法在实际工业设施中的应用的案例研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
PLC based intelligent power factor correctors for industrial power systems-A case study
In recent years, the quality of power supplied to the consumer devices by an ac system has become an issue of great concern due to the rapidly increasing inductive loads, electronic equipments, power electronic devices and high system voltage. Power factor correction (PFC) is a technique of minimizing the undesirable effects of electric loads that create poor power factor conditions. Correction of power factor may be effected either by transmission utility which improves the stability and efficiency of the transmission network or by individuals customers. This paper aims at the correction method using an intelligent power factor corrector based on PLC (Programmable Logic Controller) as a control system especially for the correction of the industrial power factor, which is not only required for the smooth operation of the electrical equipments used in the industries but also to minimize the cost of penalty that has to be paid to power supply utilities for having low power factor. This involves measuring the power factor value from the supply line using Power Meter and development of a PLC program to determine and trigger capacitor banks of required rating in order to compensate deficient reactive power, thus bringing power factor near to unity. The results of this paper is based on the case study on application of the proposed method in a real industrial facility.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信