G. Bormans , A. Janssen , P. Adriaens , D. Crombez , A. Witsenboer , J. de Goeij , L. Mortelmans , A. Verbruggen
{"title":"一种62Zn/62Cu发生器,用于62Cu- ptsm的日常生产","authors":"G. Bormans , A. Janssen , P. Adriaens , D. Crombez , A. Witsenboer , J. de Goeij , L. Mortelmans , A. Verbruggen","doi":"10.1016/0883-2889(92)90169-F","DOIUrl":null,"url":null,"abstract":"<div><p>We have developed an improved <sup>62</sup>Cu-generator system based on a small (25 mm × 5 mm) ion exchange column which allows the instant production of <sup>62</sup>Cu-PTSM ready for injection.</p><p>The generator column can rapidly be eluted with a high yield in a volume of 1 mL to afford an eluate with largely acceptable radionuclidic purity. Collection of the eluate in a labelling kit which contains the PTSM ligand in an appropriate buffer allows to obtain in less than 30 s a highly pure <sup>62</sup>Cu-PTSM preparation that can be injected intravenously.</p></div>","PeriodicalId":14288,"journal":{"name":"International Journal of Radiation Applications and Instrumentation. Part A. Applied Radiation and Isotopes","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1992-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0883-2889(92)90169-F","citationCount":"22","resultStr":"{\"title\":\"A 62Zn/62Cu generator for the routine production of 62Cu-PTSM\",\"authors\":\"G. Bormans , A. Janssen , P. Adriaens , D. Crombez , A. Witsenboer , J. de Goeij , L. Mortelmans , A. Verbruggen\",\"doi\":\"10.1016/0883-2889(92)90169-F\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>We have developed an improved <sup>62</sup>Cu-generator system based on a small (25 mm × 5 mm) ion exchange column which allows the instant production of <sup>62</sup>Cu-PTSM ready for injection.</p><p>The generator column can rapidly be eluted with a high yield in a volume of 1 mL to afford an eluate with largely acceptable radionuclidic purity. Collection of the eluate in a labelling kit which contains the PTSM ligand in an appropriate buffer allows to obtain in less than 30 s a highly pure <sup>62</sup>Cu-PTSM preparation that can be injected intravenously.</p></div>\",\"PeriodicalId\":14288,\"journal\":{\"name\":\"International Journal of Radiation Applications and Instrumentation. Part A. Applied Radiation and Isotopes\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/0883-2889(92)90169-F\",\"citationCount\":\"22\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Radiation Applications and Instrumentation. Part A. Applied Radiation and Isotopes\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/088328899290169F\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Radiation Applications and Instrumentation. Part A. Applied Radiation and Isotopes","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/088328899290169F","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A 62Zn/62Cu generator for the routine production of 62Cu-PTSM
We have developed an improved 62Cu-generator system based on a small (25 mm × 5 mm) ion exchange column which allows the instant production of 62Cu-PTSM ready for injection.
The generator column can rapidly be eluted with a high yield in a volume of 1 mL to afford an eluate with largely acceptable radionuclidic purity. Collection of the eluate in a labelling kit which contains the PTSM ligand in an appropriate buffer allows to obtain in less than 30 s a highly pure 62Cu-PTSM preparation that can be injected intravenously.