抽水机的电能审计

I. Garba, Y. Jibril, K. LaminuS.
{"title":"抽水机的电能审计","authors":"I. Garba, Y. Jibril, K. LaminuS.","doi":"10.5923/J.IJEE.20120203.05","DOIUrl":null,"url":null,"abstract":"The study involves an energy audit of Pu mps used to pump fluid fro m lower level to higher level by using electrical energy. A case study was conducted on centrifugal pu mps at Ah madu Bello University Water treat ment plant, series of energy audit was conducted to record various parameters v iz., discharge, pressure, voltage, current, power, power factor and efficiencies to calculate the total electrical energy consumption per day and total actual energy use per day, maximu m (VA )demand, maximu m (KW )demand, consumption figures of the whole pu mp in the p lant, energy cost figures of the plant in (KWh), where we discovered very high energy wastage during operation .Therefore ways to reduce energy consumption by the replacement of the present pumps with inverter co mpatible energy efficient pu mps and various conservation methods are recommended for optimu m utilizat ion, this study will help other pump ing stations.","PeriodicalId":14041,"journal":{"name":"International journal of energy engineering","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2012-05-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"An Electrical Energy Audit of Water Pumping Machines\",\"authors\":\"I. Garba, Y. Jibril, K. LaminuS.\",\"doi\":\"10.5923/J.IJEE.20120203.05\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The study involves an energy audit of Pu mps used to pump fluid fro m lower level to higher level by using electrical energy. A case study was conducted on centrifugal pu mps at Ah madu Bello University Water treat ment plant, series of energy audit was conducted to record various parameters v iz., discharge, pressure, voltage, current, power, power factor and efficiencies to calculate the total electrical energy consumption per day and total actual energy use per day, maximu m (VA )demand, maximu m (KW )demand, consumption figures of the whole pu mp in the p lant, energy cost figures of the plant in (KWh), where we discovered very high energy wastage during operation .Therefore ways to reduce energy consumption by the replacement of the present pumps with inverter co mpatible energy efficient pu mps and various conservation methods are recommended for optimu m utilizat ion, this study will help other pump ing stations.\",\"PeriodicalId\":14041,\"journal\":{\"name\":\"International journal of energy engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-05-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International journal of energy engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5923/J.IJEE.20120203.05\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of energy engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5923/J.IJEE.20120203.05","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

这项研究涉及到对利用电能将流体从较低水平泵送到较高水平的泵的能量审计。以ahmadu Bello大学水处理厂的离心式水泵为例,进行了一系列的能源审计,记录了各种参数。、放电、压力、电压、电流、功率、功率因数和效率,以计算每天的总电能消耗和每天的总实际能源使用,最大m (VA)需求,最大m (KW)需求,整个泵在电厂的消耗数字,电厂的能源成本数字(KWh),因此,我们建议将现有的水泵更换为与变频器兼容的节能水泵,并采取各种节约能源的方法,以减少能源消耗,以达到最佳利用,这项研究对其他泵站也有帮助。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An Electrical Energy Audit of Water Pumping Machines
The study involves an energy audit of Pu mps used to pump fluid fro m lower level to higher level by using electrical energy. A case study was conducted on centrifugal pu mps at Ah madu Bello University Water treat ment plant, series of energy audit was conducted to record various parameters v iz., discharge, pressure, voltage, current, power, power factor and efficiencies to calculate the total electrical energy consumption per day and total actual energy use per day, maximu m (VA )demand, maximu m (KW )demand, consumption figures of the whole pu mp in the p lant, energy cost figures of the plant in (KWh), where we discovered very high energy wastage during operation .Therefore ways to reduce energy consumption by the replacement of the present pumps with inverter co mpatible energy efficient pu mps and various conservation methods are recommended for optimu m utilizat ion, this study will help other pump ing stations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信