固相微萃取-高效液相色谱法测定环境样品中铜(II

Varinder Kaur, Ashok Kumar Malik
{"title":"固相微萃取-高效液相色谱法测定环境样品中铜(II","authors":"Varinder Kaur,&nbsp;Ashok Kumar Malik","doi":"10.1002/adic.200790113","DOIUrl":null,"url":null,"abstract":"<p>A highly sensitive solid phase microextraction – high performance liquid chromatographic method has been developed for the determination of copper(II) using morpholine-4-carbodithioate (MDTC) as an analytical reagent. The MDTC formed yellowish- brown species of copper(II) at a pH range of 2-9 and complex was sorbed onto PDMS fiber. The Cu(II)-MDTC complex shows maximum absorbance at 430 nm and can be separated on C18 column by using acetonitrile : water (80 : 20) at a flow rate of 1.0 ml min<sup>-1</sup>.The detection limit of method was found to be 0.51 μg L<sup>-1</sup>. The interference due to common metal ions were studied. The repeatability of the method was checked by finding the relative standard deviation. The developed method was successfully employed for the determination of copper(II) in different alloy samples and the results were compared with existing methods.</p>","PeriodicalId":8193,"journal":{"name":"Annali di chimica","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2007-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/adic.200790113","citationCount":"11","resultStr":"{\"title\":\"Development of Solid Phase Microextraction-High Performance Liquid Chromatographic Method for the Determination of Copper(II) in Environmental Samples Using Morpholine-4-Carbodithioate\",\"authors\":\"Varinder Kaur,&nbsp;Ashok Kumar Malik\",\"doi\":\"10.1002/adic.200790113\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>A highly sensitive solid phase microextraction – high performance liquid chromatographic method has been developed for the determination of copper(II) using morpholine-4-carbodithioate (MDTC) as an analytical reagent. The MDTC formed yellowish- brown species of copper(II) at a pH range of 2-9 and complex was sorbed onto PDMS fiber. The Cu(II)-MDTC complex shows maximum absorbance at 430 nm and can be separated on C18 column by using acetonitrile : water (80 : 20) at a flow rate of 1.0 ml min<sup>-1</sup>.The detection limit of method was found to be 0.51 μg L<sup>-1</sup>. The interference due to common metal ions were studied. The repeatability of the method was checked by finding the relative standard deviation. The developed method was successfully employed for the determination of copper(II) in different alloy samples and the results were compared with existing methods.</p>\",\"PeriodicalId\":8193,\"journal\":{\"name\":\"Annali di chimica\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-11-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1002/adic.200790113\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annali di chimica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/adic.200790113\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annali di chimica","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/adic.200790113","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

摘要

建立了以4-碳二硫酸morpholin -4-carbodithioate (MDTC)为分析试剂,固相微萃取-高效液相色谱法测定铜(II)的方法。MDTC在2 ~ 9的pH范围内形成黄褐色的铜(II),配合物被吸附在PDMS纤维上。Cu(II)-MDTC配合物在430 nm处吸光度最大,可以在C18柱上用乙腈:水(80:20),流速为1.0 ml min-1分离。方法检出限为0.51 μg L-1。研究了普通金属离子的干扰。通过计算相对标准偏差,验证了方法的重复性。该方法成功地用于不同合金样品中铜(II)的测定,并与现有方法进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Development of Solid Phase Microextraction-High Performance Liquid Chromatographic Method for the Determination of Copper(II) in Environmental Samples Using Morpholine-4-Carbodithioate

A highly sensitive solid phase microextraction – high performance liquid chromatographic method has been developed for the determination of copper(II) using morpholine-4-carbodithioate (MDTC) as an analytical reagent. The MDTC formed yellowish- brown species of copper(II) at a pH range of 2-9 and complex was sorbed onto PDMS fiber. The Cu(II)-MDTC complex shows maximum absorbance at 430 nm and can be separated on C18 column by using acetonitrile : water (80 : 20) at a flow rate of 1.0 ml min-1.The detection limit of method was found to be 0.51 μg L-1. The interference due to common metal ions were studied. The repeatability of the method was checked by finding the relative standard deviation. The developed method was successfully employed for the determination of copper(II) in different alloy samples and the results were compared with existing methods.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信