空间矢量调制交直流矩阵变换器的最优零矢量结构

B. Feng, Hua Lin, Xingwei Wang, Xing An, Bangyin Liu
{"title":"空间矢量调制交直流矩阵变换器的最优零矢量结构","authors":"B. Feng, Hua Lin, Xingwei Wang, Xing An, Bangyin Liu","doi":"10.1109/ECCE.2012.6342810","DOIUrl":null,"url":null,"abstract":"The zero-vector configurations have great influence on the performance of the practical implemented space vector modulated AC-DC matrix converter (MC). In this paper, the optimized switching pattern that reduces the output inductor current ripple and the narrow pulses is presented. The optimal zero-vector duty cycles for different switching patterns are derived based on the output inductor current ripple analysis. Further considering the commutation, the relationship of the duty cycles and the narrow pulses are discussed, and then the segmental optimized switching pattern is proposed. The proposed method can improve the input/output quality and realize wide-range output regulation. The experimental results verified the conclusions and validate the proposed strategy.","PeriodicalId":6401,"journal":{"name":"2012 IEEE Energy Conversion Congress and Exposition (ECCE)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2012-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":"{\"title\":\"Optimal zero-vector configuration for space vector modulated AC-DC matrix converter\",\"authors\":\"B. Feng, Hua Lin, Xingwei Wang, Xing An, Bangyin Liu\",\"doi\":\"10.1109/ECCE.2012.6342810\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The zero-vector configurations have great influence on the performance of the practical implemented space vector modulated AC-DC matrix converter (MC). In this paper, the optimized switching pattern that reduces the output inductor current ripple and the narrow pulses is presented. The optimal zero-vector duty cycles for different switching patterns are derived based on the output inductor current ripple analysis. Further considering the commutation, the relationship of the duty cycles and the narrow pulses are discussed, and then the segmental optimized switching pattern is proposed. The proposed method can improve the input/output quality and realize wide-range output regulation. The experimental results verified the conclusions and validate the proposed strategy.\",\"PeriodicalId\":6401,\"journal\":{\"name\":\"2012 IEEE Energy Conversion Congress and Exposition (ECCE)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-11-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"15\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 IEEE Energy Conversion Congress and Exposition (ECCE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ECCE.2012.6342810\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE Energy Conversion Congress and Exposition (ECCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECCE.2012.6342810","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

摘要

零矢量结构对实际实现的空间矢量调制交直流矩阵变换器的性能影响很大。本文提出了一种减小输出电感电流纹波和窄脉冲的优化开关方式。在输出电感电流纹波分析的基础上,导出了不同开关方式下的最佳零矢量占空比。进一步考虑换流,讨论了占空比与窄脉冲的关系,提出了分段优化开关模式。该方法可以提高输入输出质量,实现大范围输出调节。实验结果验证了上述结论,验证了所提策略的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Optimal zero-vector configuration for space vector modulated AC-DC matrix converter
The zero-vector configurations have great influence on the performance of the practical implemented space vector modulated AC-DC matrix converter (MC). In this paper, the optimized switching pattern that reduces the output inductor current ripple and the narrow pulses is presented. The optimal zero-vector duty cycles for different switching patterns are derived based on the output inductor current ripple analysis. Further considering the commutation, the relationship of the duty cycles and the narrow pulses are discussed, and then the segmental optimized switching pattern is proposed. The proposed method can improve the input/output quality and realize wide-range output regulation. The experimental results verified the conclusions and validate the proposed strategy.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信