考虑并网变流器参数变化的LCL滤波器设计

R. Meyer, A. Mertens
{"title":"考虑并网变流器参数变化的LCL滤波器设计","authors":"R. Meyer, A. Mertens","doi":"10.1109/ECCE.2012.6342772","DOIUrl":null,"url":null,"abstract":"In this paper an efficient design process of LCL filters for grid-connected converters is described. It is especially developed to design filters for converters with low switching frequency generating harmonics in the entire frequency range. In these special applications, some small parameter variations can cause the given limits, like the allowed voltage harmonics, to be exceeded. In the worst case, the resonance frequency of the filter can be excited to an unacceptable extent. To avoid this, the tolerances of the filter parameters, the grid voltage and the grid frequency are taken into account when designing the filter. This essential consideration of the parameter variations distinguishes this new method from the well-known design processes. As an example, a filter design for a 5 MW wind energy generator with full-scale three-level medium-voltage converter is regarded more detailed. Measurements on a scaled low-voltage laboratory setup validate the theoretical calculations and complete the examination. The discussed design process enables a filter design meeting all grid code requirements concerning the voltage quality for all relevant operating ranges in consideration of various parameter variations. The method is suitable for all converter topologies and modulation schemes generating periodical output voltages.","PeriodicalId":6401,"journal":{"name":"2012 IEEE Energy Conversion Congress and Exposition (ECCE)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2012-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"30","resultStr":"{\"title\":\"Design of LCL filters in consideration of parameter variations for grid-connected converters\",\"authors\":\"R. Meyer, A. Mertens\",\"doi\":\"10.1109/ECCE.2012.6342772\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper an efficient design process of LCL filters for grid-connected converters is described. It is especially developed to design filters for converters with low switching frequency generating harmonics in the entire frequency range. In these special applications, some small parameter variations can cause the given limits, like the allowed voltage harmonics, to be exceeded. In the worst case, the resonance frequency of the filter can be excited to an unacceptable extent. To avoid this, the tolerances of the filter parameters, the grid voltage and the grid frequency are taken into account when designing the filter. This essential consideration of the parameter variations distinguishes this new method from the well-known design processes. As an example, a filter design for a 5 MW wind energy generator with full-scale three-level medium-voltage converter is regarded more detailed. Measurements on a scaled low-voltage laboratory setup validate the theoretical calculations and complete the examination. The discussed design process enables a filter design meeting all grid code requirements concerning the voltage quality for all relevant operating ranges in consideration of various parameter variations. The method is suitable for all converter topologies and modulation schemes generating periodical output voltages.\",\"PeriodicalId\":6401,\"journal\":{\"name\":\"2012 IEEE Energy Conversion Congress and Exposition (ECCE)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-11-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"30\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 IEEE Energy Conversion Congress and Exposition (ECCE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ECCE.2012.6342772\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE Energy Conversion Congress and Exposition (ECCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECCE.2012.6342772","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 30

摘要

本文介绍了并网变流器LCL滤波器的高效设计过程。它是专门为在整个频率范围内产生谐波的低开关频率变换器设计滤波器而开发的。在这些特殊应用中,一些小的参数变化可能导致给定的限制,如允许的电压谐波,被超过。在最坏的情况下,滤波器的谐振频率可能被激发到不可接受的程度。为了避免这种情况,在设计滤波器时考虑了滤波器参数、电网电压和电网频率的容差。这种对参数变化的基本考虑使这种新方法区别于众所周知的设计过程。以5mw风电机组全尺寸三电平中压变换器的滤波器设计为例,进行了较为详细的研究。在低压实验室装置上的测量验证了理论计算并完成了测试。所讨论的设计过程使滤波器设计能够满足所有相关工作范围内电压质量的所有电网规范要求,并考虑各种参数变化。该方法适用于产生周期性输出电压的所有变换器拓扑结构和调制方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design of LCL filters in consideration of parameter variations for grid-connected converters
In this paper an efficient design process of LCL filters for grid-connected converters is described. It is especially developed to design filters for converters with low switching frequency generating harmonics in the entire frequency range. In these special applications, some small parameter variations can cause the given limits, like the allowed voltage harmonics, to be exceeded. In the worst case, the resonance frequency of the filter can be excited to an unacceptable extent. To avoid this, the tolerances of the filter parameters, the grid voltage and the grid frequency are taken into account when designing the filter. This essential consideration of the parameter variations distinguishes this new method from the well-known design processes. As an example, a filter design for a 5 MW wind energy generator with full-scale three-level medium-voltage converter is regarded more detailed. Measurements on a scaled low-voltage laboratory setup validate the theoretical calculations and complete the examination. The discussed design process enables a filter design meeting all grid code requirements concerning the voltage quality for all relevant operating ranges in consideration of various parameter variations. The method is suitable for all converter topologies and modulation schemes generating periodical output voltages.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信