{"title":"低剂量电离辐射对动态巯基二硫化物稳态和缺血修饰白蛋白水平的影响:观察性研究","authors":"Sule Arıcan ,&nbsp;Ramazan Dertli ,&nbsp;Suleyman Baktik ,&nbsp;Gulcin Hacibeyoglu ,&nbsp;Atilla Erol ,&nbsp;Sinan Oguzhan Ulukaya ,&nbsp;Esra Goger ,&nbsp;Özcan Erel","doi":"10.1016/j.bjan.2020.02.009","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>The primary objective of this study was to investigate the effect of low dose ionizing radiation exposure on thiol/disulfide homeostasis and ischemia modified albumin levels. The secondary objective is to compare thiol/disulfide homeostasis and ischemia modified albumin levels among the personnel exposed to low dose ionizing radiation in anesthesia application areas, in and out of the Operation room.</p></div><div><h3>Methods</h3><p>The study included a total of 90 volunteers aged between 18 and 65 years old, with 45 personnel working in a setting with potential for radiation exposure (Exposed Group) and 45 personnel in a setting without radiation exposure (Control Group). Their native thiol, total thiol, disulphide, albumine and IMA levels were measured. Exposed group included personnel who were exposed to radiation outside the operating room – Operation room (‐) Group and inside the Operating room – Operation room (+) Group.</p></div><div><h3>Results</h3><p>Albumin, native and total thiol levels were significantly lower in the participants exposed to radiation in the anesthesia application area, no statistically significant difference was found in terms of disulfide and ischemia modified albumin levels. In the Operation room (‐) group exposed to radiation, native thiol and total thiol values were significantly lower compared to the Operation room (+) groups.</p></div><div><h3>Conclusion</h3><p>Awareness of being in danger of oxidative stress should be established in personnel exposed to radiation in the anesthesia application area following low dose ionizing radiation exposure, and the necessary measures should be taken.</p></div>","PeriodicalId":21261,"journal":{"name":"Revista brasileira de anestesiologia","volume":"70 3","pages":"Pages 233-239"},"PeriodicalIF":1.0000,"publicationDate":"2020-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.bjan.2020.02.009","citationCount":"2","resultStr":"{\"title\":\"Efeito da exposição à radiação ionizante de baixa dose na homeostase dinâmica de tiol‐dissulfeto e níveis de albumina modificada por isquemia: estudo observacional\",\"authors\":\"Sule Arıcan ,&nbsp;Ramazan Dertli ,&nbsp;Suleyman Baktik ,&nbsp;Gulcin Hacibeyoglu ,&nbsp;Atilla Erol ,&nbsp;Sinan Oguzhan Ulukaya ,&nbsp;Esra Goger ,&nbsp;Özcan Erel\",\"doi\":\"10.1016/j.bjan.2020.02.009\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>The primary objective of this study was to investigate the effect of low dose ionizing radiation exposure on thiol/disulfide homeostasis and ischemia modified albumin levels. The secondary objective is to compare thiol/disulfide homeostasis and ischemia modified albumin levels among the personnel exposed to low dose ionizing radiation in anesthesia application areas, in and out of the Operation room.</p></div><div><h3>Methods</h3><p>The study included a total of 90 volunteers aged between 18 and 65 years old, with 45 personnel working in a setting with potential for radiation exposure (Exposed Group) and 45 personnel in a setting without radiation exposure (Control Group). Their native thiol, total thiol, disulphide, albumine and IMA levels were measured. Exposed group included personnel who were exposed to radiation outside the operating room – Operation room (‐) Group and inside the Operating room – Operation room (+) Group.</p></div><div><h3>Results</h3><p>Albumin, native and total thiol levels were significantly lower in the participants exposed to radiation in the anesthesia application area, no statistically significant difference was found in terms of disulfide and ischemia modified albumin levels. In the Operation room (‐) group exposed to radiation, native thiol and total thiol values were significantly lower compared to the Operation room (+) groups.</p></div><div><h3>Conclusion</h3><p>Awareness of being in danger of oxidative stress should be established in personnel exposed to radiation in the anesthesia application area following low dose ionizing radiation exposure, and the necessary measures should be taken.</p></div>\",\"PeriodicalId\":21261,\"journal\":{\"name\":\"Revista brasileira de anestesiologia\",\"volume\":\"70 3\",\"pages\":\"Pages 233-239\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2020-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.bjan.2020.02.009\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revista brasileira de anestesiologia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S003470941930529X\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista brasileira de anestesiologia","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S003470941930529X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 2

摘要

背景本研究的主要目的是研究低剂量电离辐射对硫醇/二硫化物稳态和缺血修饰白蛋白水平的影响。第二个目的是比较在麻醉应用区域、手术室内外暴露于低剂量电离辐射的人员中硫醇/二硫化物稳态和缺血修饰白蛋白水平。方法该研究共包括90名年龄在18岁至65岁之间的志愿者,其中45人在有辐射暴露潜力的环境中工作(暴露组),45人在没有辐射暴露的环境中(对照组)。测定它们的天然硫醇、总硫醇、二硫化物、白蛋白和IMA水平。暴露组包括在手术室外暴露于辐射的人员——手术室(-)组和手术室内暴露于辐射(+)组。结果在麻醉应用区暴露于辐射的受试者中,白蛋白、天然硫醇和总硫醇水平显著降低,二硫化物和缺血修饰白蛋白水平无统计学差异。在暴露于辐射的手术室(‐)组中,与手术室(+)组相比,天然硫醇和总硫醇值显著降低。结论低剂量电离辐射暴露后,麻醉应用区辐射暴露人员应树立氧化应激危险意识,并采取必要措施。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Efeito da exposição à radiação ionizante de baixa dose na homeostase dinâmica de tiol‐dissulfeto e níveis de albumina modificada por isquemia: estudo observacional

Background

The primary objective of this study was to investigate the effect of low dose ionizing radiation exposure on thiol/disulfide homeostasis and ischemia modified albumin levels. The secondary objective is to compare thiol/disulfide homeostasis and ischemia modified albumin levels among the personnel exposed to low dose ionizing radiation in anesthesia application areas, in and out of the Operation room.

Methods

The study included a total of 90 volunteers aged between 18 and 65 years old, with 45 personnel working in a setting with potential for radiation exposure (Exposed Group) and 45 personnel in a setting without radiation exposure (Control Group). Their native thiol, total thiol, disulphide, albumine and IMA levels were measured. Exposed group included personnel who were exposed to radiation outside the operating room – Operation room (‐) Group and inside the Operating room – Operation room (+) Group.

Results

Albumin, native and total thiol levels were significantly lower in the participants exposed to radiation in the anesthesia application area, no statistically significant difference was found in terms of disulfide and ischemia modified albumin levels. In the Operation room (‐) group exposed to radiation, native thiol and total thiol values were significantly lower compared to the Operation room (+) groups.

Conclusion

Awareness of being in danger of oxidative stress should be established in personnel exposed to radiation in the anesthesia application area following low dose ionizing radiation exposure, and the necessary measures should be taken.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.50
自引率
0.00%
发文量
0
审稿时长
21 weeks
期刊介绍: The Brazilian Journal of Anesthesiology is the official journal of the Brazilian Anesthesiology Society. It publishes articles classified into the following categories: -Scientific articles (clinical or experimental trials)- Clinical information (case reports)- Reviews- Letters to the Editor- Editorials. The journal focuses primarily on clinical trials, with scope on clinical practice, aiming at providing applied tools to the anesthesiologist and critical care physician. The Brazilian Journal of Anesthesiology accepts articles exclusively forwarded to it. Articles already published in other journals are not accepted. All articles proposed for publication are previously submitted to the analysis of two or more members of the Editorial Board or other specialized consultants.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信