加热NDIR法碳氢化合物分析仪的研制及其在车载质量排放测量系统中的应用

Hiroshi Nakamura, Nobutaka Kihara, Masayuki Adachi, Shigeo Nakamura, Kozo Ishida
{"title":"加热NDIR法碳氢化合物分析仪的研制及其在车载质量排放测量系统中的应用","authors":"Hiroshi Nakamura,&nbsp;Nobutaka Kihara,&nbsp;Masayuki Adachi,&nbsp;Shigeo Nakamura,&nbsp;Kozo Ishida","doi":"10.1016/S0389-4304(02)00298-9","DOIUrl":null,"url":null,"abstract":"<div><p>A heated NDIR analyzer (H-NDIR) that is capable of measuring CO, CO<sub>2</sub><span> and HC has been developed, and an on-board emission measurement system using the H-NDIR in combination with a Pitot tube flow meter has been evaluated. It has been confirmed that the results of the mass emission from on-board system shows a satisfactory agreement with those of the CVS-bag measurements in laboratory test.</span></p><p>A conversion factor applied in the present study that converts the value of NDIR measurement to correlate with the FID method is 1.66. Using the conversion factor, consistent correlation has been observed for vehicles with different fuel and combustion types.</p></div>","PeriodicalId":100855,"journal":{"name":"JSAE Review","volume":"24 2","pages":"Pages 127-133"},"PeriodicalIF":0.0000,"publicationDate":"2003-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0389-4304(02)00298-9","citationCount":"9","resultStr":"{\"title\":\"Development of hydrocarbon analyzer using heated-NDIR method and its application to on-board mass emission measurement system\",\"authors\":\"Hiroshi Nakamura,&nbsp;Nobutaka Kihara,&nbsp;Masayuki Adachi,&nbsp;Shigeo Nakamura,&nbsp;Kozo Ishida\",\"doi\":\"10.1016/S0389-4304(02)00298-9\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>A heated NDIR analyzer (H-NDIR) that is capable of measuring CO, CO<sub>2</sub><span> and HC has been developed, and an on-board emission measurement system using the H-NDIR in combination with a Pitot tube flow meter has been evaluated. It has been confirmed that the results of the mass emission from on-board system shows a satisfactory agreement with those of the CVS-bag measurements in laboratory test.</span></p><p>A conversion factor applied in the present study that converts the value of NDIR measurement to correlate with the FID method is 1.66. Using the conversion factor, consistent correlation has been observed for vehicles with different fuel and combustion types.</p></div>\",\"PeriodicalId\":100855,\"journal\":{\"name\":\"JSAE Review\",\"volume\":\"24 2\",\"pages\":\"Pages 127-133\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/S0389-4304(02)00298-9\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JSAE Review\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0389430402002989\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JSAE Review","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0389430402002989","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

已经开发了一种能够测量CO、CO2和HC的加热NDIR分析仪(H-NDIR),并对使用H-NDIR与皮托管流量计相结合的车载排放测量系统进行了评估。已经证实,车载系统的质量排放结果与实验室试验中的CVS袋测量结果一致。本研究中应用的转换因子将NDIR测量值转换为与FID方法相关,其为1.66。使用转换系数,对于具有不同燃料和燃烧类型的车辆,观察到了一致的相关性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Development of hydrocarbon analyzer using heated-NDIR method and its application to on-board mass emission measurement system

A heated NDIR analyzer (H-NDIR) that is capable of measuring CO, CO2 and HC has been developed, and an on-board emission measurement system using the H-NDIR in combination with a Pitot tube flow meter has been evaluated. It has been confirmed that the results of the mass emission from on-board system shows a satisfactory agreement with those of the CVS-bag measurements in laboratory test.

A conversion factor applied in the present study that converts the value of NDIR measurement to correlate with the FID method is 1.66. Using the conversion factor, consistent correlation has been observed for vehicles with different fuel and combustion types.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信