用于痕量氨测定的全集成微分散流动注射系统的开发

C.W.K. Chow, R. Lane, T.C.W. Yeow, D.E. Davey, D.E. Mulcahy
{"title":"用于痕量氨测定的全集成微分散流动注射系统的开发","authors":"C.W.K. Chow,&nbsp;R. Lane,&nbsp;T.C.W. Yeow,&nbsp;D.E. Davey,&nbsp;D.E. Mulcahy","doi":"10.1016/S1381-141X(98)80005-1","DOIUrl":null,"url":null,"abstract":"<div><p>An in-housed designed computerised flow injection system comprised a fully integrated microdistillation flow injection (MDFI) system for low level ammonia analysis was reported. In this system, the microdistillation separation step was incorporated into the flow injection manifold and the ammonia gas sensing probe sensing element was replaced by a flow-through micro-pH electrode which sensed the change in pH of a flowing collector solution caused by the dissolution of distilled ammonia gas, in a process analogous to that occurring in the internal solution of the gas sensing probe. A computerised control and data acquisition system was constructed for this system using a commercially available data acquisition card which offered many advantages such as improved data acquisition rates and control over the system components, as well as good graphics display and data processing options. The system was optimised using a multi-variable simplex optimisation technique.</p></div>","PeriodicalId":100862,"journal":{"name":"Laboratory Automation & Information Management","volume":"33 3","pages":"Pages 199-206"},"PeriodicalIF":0.0000,"publicationDate":"1998-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S1381-141X(98)80005-1","citationCount":"2","resultStr":"{\"title\":\"Development of a fully integrated microdistillation flow injection system for the determination of trace level ammonia\",\"authors\":\"C.W.K. Chow,&nbsp;R. Lane,&nbsp;T.C.W. Yeow,&nbsp;D.E. Davey,&nbsp;D.E. Mulcahy\",\"doi\":\"10.1016/S1381-141X(98)80005-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>An in-housed designed computerised flow injection system comprised a fully integrated microdistillation flow injection (MDFI) system for low level ammonia analysis was reported. In this system, the microdistillation separation step was incorporated into the flow injection manifold and the ammonia gas sensing probe sensing element was replaced by a flow-through micro-pH electrode which sensed the change in pH of a flowing collector solution caused by the dissolution of distilled ammonia gas, in a process analogous to that occurring in the internal solution of the gas sensing probe. A computerised control and data acquisition system was constructed for this system using a commercially available data acquisition card which offered many advantages such as improved data acquisition rates and control over the system components, as well as good graphics display and data processing options. The system was optimised using a multi-variable simplex optimisation technique.</p></div>\",\"PeriodicalId\":100862,\"journal\":{\"name\":\"Laboratory Automation & Information Management\",\"volume\":\"33 3\",\"pages\":\"Pages 199-206\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/S1381-141X(98)80005-1\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Laboratory Automation & Information Management\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1381141X98800051\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laboratory Automation & Information Management","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1381141X98800051","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

报道了一种室内设计的计算机流动注射系统,该系统包括一个用于低水平氨分析的完全集成的微分散流动注射(MDFI)系统。在该系统中,微分散分离步骤被结合到流动注入歧管中,并且氨气感测探针感测元件被流通的微pH电极代替,该电极感测由蒸馏氨气的溶解引起的流动收集器溶液的pH变化,其过程类似于在气体传感探针的内部溶液中发生的过程。使用商用数据采集卡为该系统构建了计算机控制和数据采集系统,该卡具有许多优点,如提高了数据采集率和对系统组件的控制,以及良好的图形显示和数据处理选项。使用多变量单纯形优化技术对系统进行了优化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Development of a fully integrated microdistillation flow injection system for the determination of trace level ammonia

An in-housed designed computerised flow injection system comprised a fully integrated microdistillation flow injection (MDFI) system for low level ammonia analysis was reported. In this system, the microdistillation separation step was incorporated into the flow injection manifold and the ammonia gas sensing probe sensing element was replaced by a flow-through micro-pH electrode which sensed the change in pH of a flowing collector solution caused by the dissolution of distilled ammonia gas, in a process analogous to that occurring in the internal solution of the gas sensing probe. A computerised control and data acquisition system was constructed for this system using a commercially available data acquisition card which offered many advantages such as improved data acquisition rates and control over the system components, as well as good graphics display and data processing options. The system was optimised using a multi-variable simplex optimisation technique.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信