Metin Ozbek, Nathan Voorhies, Lucas Howard, Ryan Swanson, Tad Fox
{"title":"使用PlumeSeekerTM绘制全氟辛烷磺酸羽流并评估其概念模型中的数据差距。","authors":"Metin Ozbek, Nathan Voorhies, Lucas Howard, Ryan Swanson, Tad Fox","doi":"10.1111/gwat.13373","DOIUrl":null,"url":null,"abstract":"<p>An accurate conceptual site model (CSM) and plume-delineation at contamination sites are pre-requisites for successful remediation and for satisfying regulators and stakeholders. PlumeSeeker™ is well-suited for assessing data gaps in CSMs by using available site data and for identifying the optimal number and locations of sampling locations to delineate contaminant plumes. It is an enhancement of a university research code for plume delineation using geostatistical and stochastic modeling integrated with the groundwater modeling software MODFLOW-SURFACT™. PlumeSeeker™ increases the overall confidence in the location of the plume boundary through a variance-reduction approach that selects existing- or new monitoring wells for sampling based on minimizing the uncertainty in plume boundary and on new field information. Applicable at sites with or without existing monitoring wells, PlumeSeeker™ is particularly powerful for optimally allocating project resources (labor, well installation, and laboratory costs) between existing wells and sampling at new locations. An application of PlumeSeeker™ at Lakehurst, the naval component of Joint Base McGuire-Dix-Lakehurst in New Jersey, demonstrates how the cost of delineating the migration pathway of a perfluorooctanoic acid (PFOA) plume can be minimized by requiring only 9 new sampling locations in addition to samples from 2 existing wells for achieving a 70% reduction in plume uncertainty. In addition, the use of available site data in three different scenarios identified CSM data-gaps in the source area and in the interaction between Manapaqua Branch and groundwater, where the observed high concentration in this area could have resulted from a combination of groundwater migration and induced infiltration.</p>","PeriodicalId":12866,"journal":{"name":"Groundwater","volume":"62 1","pages":"44-59"},"PeriodicalIF":2.0000,"publicationDate":"2023-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Delineation of a PFOA Plume and Assessment of Data Gaps in its Conceptual Model Using PlumeSeeker™\",\"authors\":\"Metin Ozbek, Nathan Voorhies, Lucas Howard, Ryan Swanson, Tad Fox\",\"doi\":\"10.1111/gwat.13373\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>An accurate conceptual site model (CSM) and plume-delineation at contamination sites are pre-requisites for successful remediation and for satisfying regulators and stakeholders. PlumeSeeker™ is well-suited for assessing data gaps in CSMs by using available site data and for identifying the optimal number and locations of sampling locations to delineate contaminant plumes. It is an enhancement of a university research code for plume delineation using geostatistical and stochastic modeling integrated with the groundwater modeling software MODFLOW-SURFACT™. PlumeSeeker™ increases the overall confidence in the location of the plume boundary through a variance-reduction approach that selects existing- or new monitoring wells for sampling based on minimizing the uncertainty in plume boundary and on new field information. Applicable at sites with or without existing monitoring wells, PlumeSeeker™ is particularly powerful for optimally allocating project resources (labor, well installation, and laboratory costs) between existing wells and sampling at new locations. An application of PlumeSeeker™ at Lakehurst, the naval component of Joint Base McGuire-Dix-Lakehurst in New Jersey, demonstrates how the cost of delineating the migration pathway of a perfluorooctanoic acid (PFOA) plume can be minimized by requiring only 9 new sampling locations in addition to samples from 2 existing wells for achieving a 70% reduction in plume uncertainty. In addition, the use of available site data in three different scenarios identified CSM data-gaps in the source area and in the interaction between Manapaqua Branch and groundwater, where the observed high concentration in this area could have resulted from a combination of groundwater migration and induced infiltration.</p>\",\"PeriodicalId\":12866,\"journal\":{\"name\":\"Groundwater\",\"volume\":\"62 1\",\"pages\":\"44-59\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2023-11-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Groundwater\",\"FirstCategoryId\":\"89\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/gwat.13373\",\"RegionNum\":4,\"RegionCategory\":\"地球科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"GEOSCIENCES, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Groundwater","FirstCategoryId":"89","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/gwat.13373","RegionNum":4,"RegionCategory":"地球科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"GEOSCIENCES, MULTIDISCIPLINARY","Score":null,"Total":0}
Delineation of a PFOA Plume and Assessment of Data Gaps in its Conceptual Model Using PlumeSeeker™
An accurate conceptual site model (CSM) and plume-delineation at contamination sites are pre-requisites for successful remediation and for satisfying regulators and stakeholders. PlumeSeeker™ is well-suited for assessing data gaps in CSMs by using available site data and for identifying the optimal number and locations of sampling locations to delineate contaminant plumes. It is an enhancement of a university research code for plume delineation using geostatistical and stochastic modeling integrated with the groundwater modeling software MODFLOW-SURFACT™. PlumeSeeker™ increases the overall confidence in the location of the plume boundary through a variance-reduction approach that selects existing- or new monitoring wells for sampling based on minimizing the uncertainty in plume boundary and on new field information. Applicable at sites with or without existing monitoring wells, PlumeSeeker™ is particularly powerful for optimally allocating project resources (labor, well installation, and laboratory costs) between existing wells and sampling at new locations. An application of PlumeSeeker™ at Lakehurst, the naval component of Joint Base McGuire-Dix-Lakehurst in New Jersey, demonstrates how the cost of delineating the migration pathway of a perfluorooctanoic acid (PFOA) plume can be minimized by requiring only 9 new sampling locations in addition to samples from 2 existing wells for achieving a 70% reduction in plume uncertainty. In addition, the use of available site data in three different scenarios identified CSM data-gaps in the source area and in the interaction between Manapaqua Branch and groundwater, where the observed high concentration in this area could have resulted from a combination of groundwater migration and induced infiltration.
期刊介绍:
Ground Water is the leading international journal focused exclusively on ground water. Since 1963, Ground Water has published a dynamic mix of papers on topics related to ground water including ground water flow and well hydraulics, hydrogeochemistry and contaminant hydrogeology, application of geophysics, groundwater management and policy, and history of ground water hydrology. This is the journal you can count on to bring you the practical applications in ground water hydrology.