矩形锥形短柄比锥形楔形短柄更好地保留了近端骨密度。

IF 0.5 4区 医学 Q4 ORTHOPEDICS
K Anjiki, S Hayashi, T Fujishiro, T Hiranaka, R Kuroda, T Matsumoto
{"title":"矩形锥形短柄比锥形楔形短柄更好地保留了近端骨密度。","authors":"K Anjiki, S Hayashi, T Fujishiro, T Hiranaka, R Kuroda, T Matsumoto","doi":"10.52628/89.3.11833","DOIUrl":null,"url":null,"abstract":"<p><p>Fitmore stem is a rectangular, tapered, short, cementless stem. A characteristic feature of this stem is that it provides rotational stability due to the high medullary occupancy achieved by its rectangular cross-section and thick antero- posterior width. We aimed to investigate the differences in periprosthetic bone remodelling between a rectangular- tapered short stem and a short tapered-wedge stem. Eighty patients who underwent primary total hip arthroplasty using a rectangular-tapered short stem (Fitmore) or a short tapered-wedge stem (Tri-Lock BPS) were enrolled in this study. Bone mineral densities (BMDs) in the seven Gruen zones were evaluated using dual-energy X-ray absorptiometry at baseline, and at 6 and 24 months postoperatively. Peri-prosthetic BMD and clinical factors were assessed and compared. In addition, correlations between periprosthetic BMD changes and stem anteversion error were analyzed using Pearson's correlation coefficient in the two groups. A significantly better postoperative periprosthetic BMD change was found in zones 1 and 7 in the rectangular-tapered group. Additionally, no significant correlation was observed between stem anteversion error and periprosthetic BMD changes in the rectangular-tapered groups. However, in the tapered-wedge group, there were significant negative correlations between the stem anteversion error and BMD changes at 6 months and 24 months in zones 1 and 7. In the rectangular-tapered group, a significantly better postoperative periprosthetic BMD change was found particularly in the region proximal to the stem. Rectangular-tapered short stem can be more resistant to rotation due to higher medullary occupancy and may lead to better periprosthetic BMD than the tapered-wedge short stem, especially in the proximal region of the stem.</p>","PeriodicalId":7018,"journal":{"name":"Acta orthopaedica Belgica","volume":"89 3","pages":"491-497"},"PeriodicalIF":0.5000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Rectangular tapered short stem excellently preserves proximal bone mineral density preservation than tapered wedge short stem.\",\"authors\":\"K Anjiki, S Hayashi, T Fujishiro, T Hiranaka, R Kuroda, T Matsumoto\",\"doi\":\"10.52628/89.3.11833\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Fitmore stem is a rectangular, tapered, short, cementless stem. A characteristic feature of this stem is that it provides rotational stability due to the high medullary occupancy achieved by its rectangular cross-section and thick antero- posterior width. We aimed to investigate the differences in periprosthetic bone remodelling between a rectangular- tapered short stem and a short tapered-wedge stem. Eighty patients who underwent primary total hip arthroplasty using a rectangular-tapered short stem (Fitmore) or a short tapered-wedge stem (Tri-Lock BPS) were enrolled in this study. Bone mineral densities (BMDs) in the seven Gruen zones were evaluated using dual-energy X-ray absorptiometry at baseline, and at 6 and 24 months postoperatively. Peri-prosthetic BMD and clinical factors were assessed and compared. In addition, correlations between periprosthetic BMD changes and stem anteversion error were analyzed using Pearson's correlation coefficient in the two groups. A significantly better postoperative periprosthetic BMD change was found in zones 1 and 7 in the rectangular-tapered group. Additionally, no significant correlation was observed between stem anteversion error and periprosthetic BMD changes in the rectangular-tapered groups. However, in the tapered-wedge group, there were significant negative correlations between the stem anteversion error and BMD changes at 6 months and 24 months in zones 1 and 7. In the rectangular-tapered group, a significantly better postoperative periprosthetic BMD change was found particularly in the region proximal to the stem. Rectangular-tapered short stem can be more resistant to rotation due to higher medullary occupancy and may lead to better periprosthetic BMD than the tapered-wedge short stem, especially in the proximal region of the stem.</p>\",\"PeriodicalId\":7018,\"journal\":{\"name\":\"Acta orthopaedica Belgica\",\"volume\":\"89 3\",\"pages\":\"491-497\"},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2023-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta orthopaedica Belgica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.52628/89.3.11833\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta orthopaedica Belgica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.52628/89.3.11833","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

Fitmore阀杆是一种矩形、锥形、短的非水泥阀杆。该干的一个特征是,由于其矩形横截面和厚的前后宽度实现了高的髓质占有率,因此它提供了旋转稳定性。我们的目的是研究矩形锥形短柄和楔形短柄在假体周围骨重塑方面的差异。本研究纳入了80名使用矩形锥形短柄(Fitmore)或短锥形楔形柄(Tri-Lock BPS)进行初次全髋关节置换术的患者。在基线时、术后6个月和24个月时,使用双能X射线吸收法评估七个Gruen区的骨密度(BMD)。评估并比较假体周围骨密度和临床因素。此外,使用Pearson相关系数分析了两组假体周围BMD变化与干前倾角误差之间的相关性。矩形锥形组的1区和7区假体周围BMD变化明显改善。此外,在矩形锥形组中,未观察到假体前倾角误差与假体周围BMD变化之间的显著相关性。然而,在锥形楔组中,1区和7区6个月和24个月时,干前倾角误差与BMD变化之间存在显著的负相关。在矩形锥形组中,发现术后假体周围BMD变化明显更好,尤其是在靠近干细胞的区域。矩形锥形短柄比锥形楔形短柄更能抵抗旋转,这是因为髓腔占据率更高,并且可能比楔形短柄带来更好的假体周围BMD,尤其是在柄的近端区域。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Rectangular tapered short stem excellently preserves proximal bone mineral density preservation than tapered wedge short stem.

Fitmore stem is a rectangular, tapered, short, cementless stem. A characteristic feature of this stem is that it provides rotational stability due to the high medullary occupancy achieved by its rectangular cross-section and thick antero- posterior width. We aimed to investigate the differences in periprosthetic bone remodelling between a rectangular- tapered short stem and a short tapered-wedge stem. Eighty patients who underwent primary total hip arthroplasty using a rectangular-tapered short stem (Fitmore) or a short tapered-wedge stem (Tri-Lock BPS) were enrolled in this study. Bone mineral densities (BMDs) in the seven Gruen zones were evaluated using dual-energy X-ray absorptiometry at baseline, and at 6 and 24 months postoperatively. Peri-prosthetic BMD and clinical factors were assessed and compared. In addition, correlations between periprosthetic BMD changes and stem anteversion error were analyzed using Pearson's correlation coefficient in the two groups. A significantly better postoperative periprosthetic BMD change was found in zones 1 and 7 in the rectangular-tapered group. Additionally, no significant correlation was observed between stem anteversion error and periprosthetic BMD changes in the rectangular-tapered groups. However, in the tapered-wedge group, there were significant negative correlations between the stem anteversion error and BMD changes at 6 months and 24 months in zones 1 and 7. In the rectangular-tapered group, a significantly better postoperative periprosthetic BMD change was found particularly in the region proximal to the stem. Rectangular-tapered short stem can be more resistant to rotation due to higher medullary occupancy and may lead to better periprosthetic BMD than the tapered-wedge short stem, especially in the proximal region of the stem.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Acta orthopaedica Belgica
Acta orthopaedica Belgica 医学-整形外科
CiteScore
0.70
自引率
0.00%
发文量
58
审稿时长
4-8 weeks
期刊介绍: Information not localized
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信