混合制造商的双活动轴承和Exeter V40阀杆:它安全吗?初次和翻修髋关节置换术的短期疗效。

IF 0.5 4区 医学 Q4 ORTHOPEDICS
Christopher P Wakeling, Matthew J Wilson, Sarah L Whitehouse, Jonathan R Howell
{"title":"混合制造商的双活动轴承和Exeter V40阀杆:它安全吗?初次和翻修髋关节置换术的短期疗效。","authors":"Christopher P Wakeling,&nbsp;Matthew J Wilson,&nbsp;Sarah L Whitehouse,&nbsp;Jonathan R Howell","doi":"10.52628/89.2.6812","DOIUrl":null,"url":null,"abstract":"<p><p>The aim is to review clinical and radiological outcomes for all cases of primary and revision THA, combining a cemented stem (Exeter V40) with a dual mobility component from a different manufacturer (SERF Novae), to evaluate whether concerns regarding mixing components from different manufacturers are justified. We identified 72 hip replacements performed between May 2010 and December 2015 using the SERF Novae dual mobility cup with an Exeter V40 stem, the majority of which were cemented (90%) and revisions (58%). Patients were evaluated clinically and radiologically at a minimum of two years. There were five (6.9%) dislocations; three (4.2%) requiring revision - one of which was an intra-prosthetic disarticulation and two infections. No cases were lost to follow-up and 49 surviving cases were reviewed at a mean of 4.0 (range 1.8-8.1) years following surgery. Pain and functional outcome scores all improved. There were no radiological failures and no revisions for aseptic loosening of stem or cup. The combination of Exeter cemented stem with a dual mobility bearing from a different manufacturer results in acceptable short-term outcomes in terms of hip stability, revision rates and patient-reported measures.</p>","PeriodicalId":7018,"journal":{"name":"Acta orthopaedica Belgica","volume":null,"pages":null},"PeriodicalIF":0.5000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Mixed manufacturer dual mobility bearing and the Exeter V40 Stem: is it safe? Short-term results in primary and revision hip replacement.\",\"authors\":\"Christopher P Wakeling,&nbsp;Matthew J Wilson,&nbsp;Sarah L Whitehouse,&nbsp;Jonathan R Howell\",\"doi\":\"10.52628/89.2.6812\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The aim is to review clinical and radiological outcomes for all cases of primary and revision THA, combining a cemented stem (Exeter V40) with a dual mobility component from a different manufacturer (SERF Novae), to evaluate whether concerns regarding mixing components from different manufacturers are justified. We identified 72 hip replacements performed between May 2010 and December 2015 using the SERF Novae dual mobility cup with an Exeter V40 stem, the majority of which were cemented (90%) and revisions (58%). Patients were evaluated clinically and radiologically at a minimum of two years. There were five (6.9%) dislocations; three (4.2%) requiring revision - one of which was an intra-prosthetic disarticulation and two infections. No cases were lost to follow-up and 49 surviving cases were reviewed at a mean of 4.0 (range 1.8-8.1) years following surgery. Pain and functional outcome scores all improved. There were no radiological failures and no revisions for aseptic loosening of stem or cup. The combination of Exeter cemented stem with a dual mobility bearing from a different manufacturer results in acceptable short-term outcomes in terms of hip stability, revision rates and patient-reported measures.</p>\",\"PeriodicalId\":7018,\"journal\":{\"name\":\"Acta orthopaedica Belgica\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2023-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta orthopaedica Belgica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.52628/89.2.6812\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta orthopaedica Belgica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.52628/89.2.6812","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

目的是审查所有原发性和翻修性THA病例的临床和放射学结果,将水泥柄(Exeter V40)与不同制造商的双移动性组件(SERF Novae)相结合,以评估对不同制造商的混合组件的担忧是否合理。我们确定了在2010年5月至2015年12月期间使用SERF Novae双活动杯和Exeter V40干假体进行的72例髋关节置换术,其中大多数是骨水泥(90%)和翻修(58%)。至少在两年内对患者进行临床和放射学评估。有5个(6.9%)位错;三例(4.2%)需要翻修,其中一例为假体内关节脱位,两例感染。随访中没有病例丢失,49例存活病例在手术后平均4.0年(范围1.8-8.1)进行了复查。疼痛和功能结果评分均有所改善。没有放射性故障,也没有对阀杆或杯状物的无菌性松动进行翻修。Exeter骨水泥柄与来自不同制造商的双活动轴承的组合在髋关节稳定性、翻修率和患者报告的测量方面产生了可接受的短期结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Mixed manufacturer dual mobility bearing and the Exeter V40 Stem: is it safe? Short-term results in primary and revision hip replacement.

The aim is to review clinical and radiological outcomes for all cases of primary and revision THA, combining a cemented stem (Exeter V40) with a dual mobility component from a different manufacturer (SERF Novae), to evaluate whether concerns regarding mixing components from different manufacturers are justified. We identified 72 hip replacements performed between May 2010 and December 2015 using the SERF Novae dual mobility cup with an Exeter V40 stem, the majority of which were cemented (90%) and revisions (58%). Patients were evaluated clinically and radiologically at a minimum of two years. There were five (6.9%) dislocations; three (4.2%) requiring revision - one of which was an intra-prosthetic disarticulation and two infections. No cases were lost to follow-up and 49 surviving cases were reviewed at a mean of 4.0 (range 1.8-8.1) years following surgery. Pain and functional outcome scores all improved. There were no radiological failures and no revisions for aseptic loosening of stem or cup. The combination of Exeter cemented stem with a dual mobility bearing from a different manufacturer results in acceptable short-term outcomes in terms of hip stability, revision rates and patient-reported measures.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Acta orthopaedica Belgica
Acta orthopaedica Belgica 医学-整形外科
CiteScore
0.70
自引率
0.00%
发文量
58
审稿时长
4-8 weeks
期刊介绍: Information not localized
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信