Miguel Tovar-Bazaga, David Sáez-Martínez, Álvaro Auñón, Felipe López-Oliva, Emilio Calvo
{"title":"骨水泥对骨水泥去除系统在髋关节和膝关节置换翻修手术中的有效性和安全性。","authors":"Miguel Tovar-Bazaga, David Sáez-Martínez, Álvaro Auñón, Felipe López-Oliva, Emilio Calvo","doi":"10.52628/89.2.11562","DOIUrl":null,"url":null,"abstract":"<p><p>Cement removal during hip or knee arthroplasty revision is challenging and not exempt of complications. Cement-on-cement procedure is among techniques developed to safe removal of cement from bone, and it could be a realistic solution. This cement-on-cement devices can provide advantages in removing bone cement during hip and knee arthroplasty septic and non-septic revision surgeries, and can be regarded as an effective and safe alternative. We present our experience using the cement-on-cement technique in 34 cases between 2010 and 2021, including revision surgeries for 20 knee and 14 hip arthroplasties. In 3 out of 34 cases the technique failed, with a success of 91%. Mean surgical time was 2.77 (SD 0.93) hours and blood transfusion was required in 23 cases. Success was achieved in every aseptic case. Of all patients, 60% were septic cases. Infection was considered to be eradicated in 70% (14/20) of patients with a septic revision. Cement-on-cement is a safe and effective alternative for cement removal during hip and knee arthroplasty revision. Level of evidence: III, retrospective case series.</p>","PeriodicalId":7018,"journal":{"name":"Acta orthopaedica Belgica","volume":null,"pages":null},"PeriodicalIF":0.5000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effectiveness and safety of a cement-on-cement removal system for hip and knee arthroplasty revision surgery.\",\"authors\":\"Miguel Tovar-Bazaga, David Sáez-Martínez, Álvaro Auñón, Felipe López-Oliva, Emilio Calvo\",\"doi\":\"10.52628/89.2.11562\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Cement removal during hip or knee arthroplasty revision is challenging and not exempt of complications. Cement-on-cement procedure is among techniques developed to safe removal of cement from bone, and it could be a realistic solution. This cement-on-cement devices can provide advantages in removing bone cement during hip and knee arthroplasty septic and non-septic revision surgeries, and can be regarded as an effective and safe alternative. We present our experience using the cement-on-cement technique in 34 cases between 2010 and 2021, including revision surgeries for 20 knee and 14 hip arthroplasties. In 3 out of 34 cases the technique failed, with a success of 91%. Mean surgical time was 2.77 (SD 0.93) hours and blood transfusion was required in 23 cases. Success was achieved in every aseptic case. Of all patients, 60% were septic cases. Infection was considered to be eradicated in 70% (14/20) of patients with a septic revision. Cement-on-cement is a safe and effective alternative for cement removal during hip and knee arthroplasty revision. Level of evidence: III, retrospective case series.</p>\",\"PeriodicalId\":7018,\"journal\":{\"name\":\"Acta orthopaedica Belgica\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2023-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta orthopaedica Belgica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.52628/89.2.11562\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta orthopaedica Belgica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.52628/89.2.11562","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Effectiveness and safety of a cement-on-cement removal system for hip and knee arthroplasty revision surgery.
Cement removal during hip or knee arthroplasty revision is challenging and not exempt of complications. Cement-on-cement procedure is among techniques developed to safe removal of cement from bone, and it could be a realistic solution. This cement-on-cement devices can provide advantages in removing bone cement during hip and knee arthroplasty septic and non-septic revision surgeries, and can be regarded as an effective and safe alternative. We present our experience using the cement-on-cement technique in 34 cases between 2010 and 2021, including revision surgeries for 20 knee and 14 hip arthroplasties. In 3 out of 34 cases the technique failed, with a success of 91%. Mean surgical time was 2.77 (SD 0.93) hours and blood transfusion was required in 23 cases. Success was achieved in every aseptic case. Of all patients, 60% were septic cases. Infection was considered to be eradicated in 70% (14/20) of patients with a septic revision. Cement-on-cement is a safe and effective alternative for cement removal during hip and knee arthroplasty revision. Level of evidence: III, retrospective case series.