描述神经危重症患者的嗅觉障碍。

IF 2.7 3区 医学 Q2 CRITICAL CARE MEDICINE
Ciji Saju, Arianna Barnes, Joji B Kuramatsu, Jade L Marshall, Hirofumi Obinata, Ava M Puccio, Shoji Yokobori, DaiWai M Olson
{"title":"描述神经危重症患者的嗅觉障碍。","authors":"Ciji Saju, Arianna Barnes, Joji B Kuramatsu, Jade L Marshall, Hirofumi Obinata, Ava M Puccio, Shoji Yokobori, DaiWai M Olson","doi":"10.4037/ajcc2023558","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Anisocoria (unequal pupil size) has been defined using cut points ranging from greater than 0.3 mm to greater than 2.0 mm for absolute difference in pupil size. This study explored different pupil diameter cut points for assessing anisocoria as measured by quantitative pupillometry before and after light stimulus.</p><p><strong>Methods: </strong>An exploratory descriptive study of international registry data was performed. The first observations in patients with paired left and right quantitative pupillometry measurements were included. Measurements of pupil size before and after stimulus with a fixed light source were used to calculate anisocoria.</p><p><strong>Results: </strong>The sample included 5769 patients (mean [SD] age, 57.5 [17.6] years; female sex, 2558 patients [51.5%]; White race, 3669 patients [75.5%]). Anisocoria defined as pupil size difference of greater than 0.5 mm was present in 1624 patients (28.2%) before light stimulus; 645 of these patients (39.7%) also had anisocoria after light stimulus (P < .001). Anisocoria defined as pupil size difference of greater than 2.0 mm was present in 79 patients (1.4%) before light stimulus; 42 of these patients (53.2%) also had anisocoria after light stimulus (P < .001).</p><p><strong>Discussion: </strong>The finding of anisocoria significantly differed before and after light stimulus and according to the cut point used. At most cut points, fewer than half of the patients who had anisocoria before light stimulus also had anisocoria after light stimulus.</p><p><strong>Conclusion: </strong>The profound difference in the number of patients adjudicated as having anisocoria using different cut points reinforces the need to develop a universal definition for anisocoria.</p>","PeriodicalId":7607,"journal":{"name":"American Journal of Critical Care","volume":"32 6","pages":"402-409"},"PeriodicalIF":2.7000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Describing Anisocoria in Neurocritically Ill Patients.\",\"authors\":\"Ciji Saju, Arianna Barnes, Joji B Kuramatsu, Jade L Marshall, Hirofumi Obinata, Ava M Puccio, Shoji Yokobori, DaiWai M Olson\",\"doi\":\"10.4037/ajcc2023558\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Anisocoria (unequal pupil size) has been defined using cut points ranging from greater than 0.3 mm to greater than 2.0 mm for absolute difference in pupil size. This study explored different pupil diameter cut points for assessing anisocoria as measured by quantitative pupillometry before and after light stimulus.</p><p><strong>Methods: </strong>An exploratory descriptive study of international registry data was performed. The first observations in patients with paired left and right quantitative pupillometry measurements were included. Measurements of pupil size before and after stimulus with a fixed light source were used to calculate anisocoria.</p><p><strong>Results: </strong>The sample included 5769 patients (mean [SD] age, 57.5 [17.6] years; female sex, 2558 patients [51.5%]; White race, 3669 patients [75.5%]). Anisocoria defined as pupil size difference of greater than 0.5 mm was present in 1624 patients (28.2%) before light stimulus; 645 of these patients (39.7%) also had anisocoria after light stimulus (P < .001). Anisocoria defined as pupil size difference of greater than 2.0 mm was present in 79 patients (1.4%) before light stimulus; 42 of these patients (53.2%) also had anisocoria after light stimulus (P < .001).</p><p><strong>Discussion: </strong>The finding of anisocoria significantly differed before and after light stimulus and according to the cut point used. At most cut points, fewer than half of the patients who had anisocoria before light stimulus also had anisocoria after light stimulus.</p><p><strong>Conclusion: </strong>The profound difference in the number of patients adjudicated as having anisocoria using different cut points reinforces the need to develop a universal definition for anisocoria.</p>\",\"PeriodicalId\":7607,\"journal\":{\"name\":\"American Journal of Critical Care\",\"volume\":\"32 6\",\"pages\":\"402-409\"},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2023-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American Journal of Critical Care\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4037/ajcc2023558\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CRITICAL CARE MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Critical Care","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4037/ajcc2023558","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CRITICAL CARE MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

背景:对于瞳孔大小的绝对差异,已经使用从大于0.3mm到大于2.0mm的切割点定义了不等瞳孔大小。本研究探讨了在光刺激前后通过定量瞳孔测量法测量的不同瞳孔直径切割点用于评估不等斜视。方法:对国际注册数据进行探索性描述性研究。首次对左右配对定量瞳孔测量的患者进行观察。使用固定光源刺激前后瞳孔大小的测量值来计算各向异性。结果:该样本包括5769名患者(平均[SD]年龄57.5[17.6]岁;女性2558名患者[51.5%];白人3669名患者[75.5%]);其中645例(39.7%)患者在光刺激后也出现了不等斜视(P<.001)。79例(1.4%)患者在接受光刺激前出现了瞳孔大小差异大于2.0 mm的不等斜视;其中42例(53.2%)患者在光刺激后也有不等径畸形(P<.001)。讨论:光刺激前后以及根据使用的切割点,不等径畸形的发现有显著差异。在大多数切割点,在光刺激前有不等径的患者中,只有不到一半的患者在光刺激后也有不等径。结论:使用不同的切入点,被判定为不等径畸形的患者数量存在巨大差异,这加强了对不等径畸形制定通用定义的必要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Describing Anisocoria in Neurocritically Ill Patients.

Background: Anisocoria (unequal pupil size) has been defined using cut points ranging from greater than 0.3 mm to greater than 2.0 mm for absolute difference in pupil size. This study explored different pupil diameter cut points for assessing anisocoria as measured by quantitative pupillometry before and after light stimulus.

Methods: An exploratory descriptive study of international registry data was performed. The first observations in patients with paired left and right quantitative pupillometry measurements were included. Measurements of pupil size before and after stimulus with a fixed light source were used to calculate anisocoria.

Results: The sample included 5769 patients (mean [SD] age, 57.5 [17.6] years; female sex, 2558 patients [51.5%]; White race, 3669 patients [75.5%]). Anisocoria defined as pupil size difference of greater than 0.5 mm was present in 1624 patients (28.2%) before light stimulus; 645 of these patients (39.7%) also had anisocoria after light stimulus (P < .001). Anisocoria defined as pupil size difference of greater than 2.0 mm was present in 79 patients (1.4%) before light stimulus; 42 of these patients (53.2%) also had anisocoria after light stimulus (P < .001).

Discussion: The finding of anisocoria significantly differed before and after light stimulus and according to the cut point used. At most cut points, fewer than half of the patients who had anisocoria before light stimulus also had anisocoria after light stimulus.

Conclusion: The profound difference in the number of patients adjudicated as having anisocoria using different cut points reinforces the need to develop a universal definition for anisocoria.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.30
自引率
3.70%
发文量
103
审稿时长
6-12 weeks
期刊介绍: The editors of the American Journal of Critical Care (AJCC) invite authors to submit original manuscripts describing investigations, advances, or observations from all specialties related to the care of critically and acutely ill patients. Papers promoting collaborative practice and research are encouraged. Manuscripts will be considered on the understanding that they have not been published elsewhere and have been submitted solely to AJCC.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信