使用肝脏分割和分析包的肝脏计算机断层体积测量:内部和内部可靠性研究

J. Childs, K. Thoirs, A. Esterman
{"title":"使用肝脏分割和分析包的肝脏计算机断层体积测量:内部和内部可靠性研究","authors":"J. Childs, K. Thoirs, A. Esterman","doi":"10.5430/JBGC.V5N2P17","DOIUrl":null,"url":null,"abstract":"Introduction: Recent advances in technology have seen the introduction of software assisted image post-processing (SAIP)tools to calculate the volume of the liver from Computed Tomography (CT) images. One such SAIP tool is the semi-automatedPhilips liver segmentation and analysis package (Endhoven, The Netherlands). The intra- and inter-rater reliability of the livervolumes of 16 participants calculated using this tool was assessed. Methods: Two CT Technologists accessed Abdominal CT data sets and calculated the volume of the liver using the Philips liversegmentation and analysis package. One technologist repeated their calculation. Results: Results demonstrated high intra-rater reliability (ICC 0.9997) and high inter-rater reliability (ICC 0.99994). Analysiswith Bland Altman plots showed the mean bias for both intra- and inter-rater reliability to be close to zero with acceptable limitsof agreement. Conclusions: This study has shown that liver volume measurements using the Philips SAIP (Endhoven, The Netherlands) can betaken reliably by CT technologists, with confidence that the same results would be obtained between different CT technologists.","PeriodicalId":89580,"journal":{"name":"Journal of biomedical graphics and computing","volume":"5 1","pages":"17"},"PeriodicalIF":0.0000,"publicationDate":"2015-07-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.5430/JBGC.V5N2P17","citationCount":"5","resultStr":"{\"title\":\"Computed tomography volume measurements of the liver using a liver segmentation and analysis package: an intra- and inter-rater reliability study\",\"authors\":\"J. Childs, K. Thoirs, A. Esterman\",\"doi\":\"10.5430/JBGC.V5N2P17\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction: Recent advances in technology have seen the introduction of software assisted image post-processing (SAIP)tools to calculate the volume of the liver from Computed Tomography (CT) images. One such SAIP tool is the semi-automatedPhilips liver segmentation and analysis package (Endhoven, The Netherlands). The intra- and inter-rater reliability of the livervolumes of 16 participants calculated using this tool was assessed. Methods: Two CT Technologists accessed Abdominal CT data sets and calculated the volume of the liver using the Philips liversegmentation and analysis package. One technologist repeated their calculation. Results: Results demonstrated high intra-rater reliability (ICC 0.9997) and high inter-rater reliability (ICC 0.99994). Analysiswith Bland Altman plots showed the mean bias for both intra- and inter-rater reliability to be close to zero with acceptable limitsof agreement. Conclusions: This study has shown that liver volume measurements using the Philips SAIP (Endhoven, The Netherlands) can betaken reliably by CT technologists, with confidence that the same results would be obtained between different CT technologists.\",\"PeriodicalId\":89580,\"journal\":{\"name\":\"Journal of biomedical graphics and computing\",\"volume\":\"5 1\",\"pages\":\"17\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-07-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.5430/JBGC.V5N2P17\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of biomedical graphics and computing\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5430/JBGC.V5N2P17\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of biomedical graphics and computing","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5430/JBGC.V5N2P17","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

简介:最近的技术进步已经看到了软件辅助图像后处理(SAIP)工具的引入,可以从计算机断层扫描(CT)图像中计算肝脏的体积。一个这样的SAIP工具是半自动飞利浦肝脏分割和分析包(Endhoven, Netherlands)。评估了使用该工具计算的16名参与者肝脏体积的内部和内部可靠性。方法:两名CT技术人员获取腹部CT数据集,使用Philips肝脏分割分析软件包计算肝脏体积。一位技术专家重复了他们的计算。结果:结果显示高的评估内信度(ICC 0.9997)和高的评估间信度(ICC 0.99994)。Bland Altman图分析显示,在可接受的一致限度内,评级内和评级间信度的平均偏差接近于零。结论:本研究表明,使用Philips SAIP (Endhoven, the Netherlands)进行肝脏体积测量可以由CT技术人员可靠地进行,并且确信不同的CT技术人员可以获得相同的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Computed tomography volume measurements of the liver using a liver segmentation and analysis package: an intra- and inter-rater reliability study
Introduction: Recent advances in technology have seen the introduction of software assisted image post-processing (SAIP)tools to calculate the volume of the liver from Computed Tomography (CT) images. One such SAIP tool is the semi-automatedPhilips liver segmentation and analysis package (Endhoven, The Netherlands). The intra- and inter-rater reliability of the livervolumes of 16 participants calculated using this tool was assessed. Methods: Two CT Technologists accessed Abdominal CT data sets and calculated the volume of the liver using the Philips liversegmentation and analysis package. One technologist repeated their calculation. Results: Results demonstrated high intra-rater reliability (ICC 0.9997) and high inter-rater reliability (ICC 0.99994). Analysiswith Bland Altman plots showed the mean bias for both intra- and inter-rater reliability to be close to zero with acceptable limitsof agreement. Conclusions: This study has shown that liver volume measurements using the Philips SAIP (Endhoven, The Netherlands) can betaken reliably by CT technologists, with confidence that the same results would be obtained between different CT technologists.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信