{"title":"使用肝脏分割和分析包的肝脏计算机断层体积测量:内部和内部可靠性研究","authors":"J. Childs, K. Thoirs, A. Esterman","doi":"10.5430/JBGC.V5N2P17","DOIUrl":null,"url":null,"abstract":"Introduction: Recent advances in technology have seen the introduction of software assisted image post-processing (SAIP)tools to calculate the volume of the liver from Computed Tomography (CT) images. One such SAIP tool is the semi-automatedPhilips liver segmentation and analysis package (Endhoven, The Netherlands). The intra- and inter-rater reliability of the livervolumes of 16 participants calculated using this tool was assessed. Methods: Two CT Technologists accessed Abdominal CT data sets and calculated the volume of the liver using the Philips liversegmentation and analysis package. One technologist repeated their calculation. Results: Results demonstrated high intra-rater reliability (ICC 0.9997) and high inter-rater reliability (ICC 0.99994). Analysiswith Bland Altman plots showed the mean bias for both intra- and inter-rater reliability to be close to zero with acceptable limitsof agreement. Conclusions: This study has shown that liver volume measurements using the Philips SAIP (Endhoven, The Netherlands) can betaken reliably by CT technologists, with confidence that the same results would be obtained between different CT technologists.","PeriodicalId":89580,"journal":{"name":"Journal of biomedical graphics and computing","volume":"5 1","pages":"17"},"PeriodicalIF":0.0000,"publicationDate":"2015-07-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.5430/JBGC.V5N2P17","citationCount":"5","resultStr":"{\"title\":\"Computed tomography volume measurements of the liver using a liver segmentation and analysis package: an intra- and inter-rater reliability study\",\"authors\":\"J. Childs, K. Thoirs, A. Esterman\",\"doi\":\"10.5430/JBGC.V5N2P17\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction: Recent advances in technology have seen the introduction of software assisted image post-processing (SAIP)tools to calculate the volume of the liver from Computed Tomography (CT) images. One such SAIP tool is the semi-automatedPhilips liver segmentation and analysis package (Endhoven, The Netherlands). The intra- and inter-rater reliability of the livervolumes of 16 participants calculated using this tool was assessed. Methods: Two CT Technologists accessed Abdominal CT data sets and calculated the volume of the liver using the Philips liversegmentation and analysis package. One technologist repeated their calculation. Results: Results demonstrated high intra-rater reliability (ICC 0.9997) and high inter-rater reliability (ICC 0.99994). Analysiswith Bland Altman plots showed the mean bias for both intra- and inter-rater reliability to be close to zero with acceptable limitsof agreement. Conclusions: This study has shown that liver volume measurements using the Philips SAIP (Endhoven, The Netherlands) can betaken reliably by CT technologists, with confidence that the same results would be obtained between different CT technologists.\",\"PeriodicalId\":89580,\"journal\":{\"name\":\"Journal of biomedical graphics and computing\",\"volume\":\"5 1\",\"pages\":\"17\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-07-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.5430/JBGC.V5N2P17\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of biomedical graphics and computing\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5430/JBGC.V5N2P17\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of biomedical graphics and computing","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5430/JBGC.V5N2P17","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5
摘要
简介:最近的技术进步已经看到了软件辅助图像后处理(SAIP)工具的引入,可以从计算机断层扫描(CT)图像中计算肝脏的体积。一个这样的SAIP工具是半自动飞利浦肝脏分割和分析包(Endhoven, Netherlands)。评估了使用该工具计算的16名参与者肝脏体积的内部和内部可靠性。方法:两名CT技术人员获取腹部CT数据集,使用Philips肝脏分割分析软件包计算肝脏体积。一位技术专家重复了他们的计算。结果:结果显示高的评估内信度(ICC 0.9997)和高的评估间信度(ICC 0.99994)。Bland Altman图分析显示,在可接受的一致限度内,评级内和评级间信度的平均偏差接近于零。结论:本研究表明,使用Philips SAIP (Endhoven, the Netherlands)进行肝脏体积测量可以由CT技术人员可靠地进行,并且确信不同的CT技术人员可以获得相同的结果。
Computed tomography volume measurements of the liver using a liver segmentation and analysis package: an intra- and inter-rater reliability study
Introduction: Recent advances in technology have seen the introduction of software assisted image post-processing (SAIP)tools to calculate the volume of the liver from Computed Tomography (CT) images. One such SAIP tool is the semi-automatedPhilips liver segmentation and analysis package (Endhoven, The Netherlands). The intra- and inter-rater reliability of the livervolumes of 16 participants calculated using this tool was assessed. Methods: Two CT Technologists accessed Abdominal CT data sets and calculated the volume of the liver using the Philips liversegmentation and analysis package. One technologist repeated their calculation. Results: Results demonstrated high intra-rater reliability (ICC 0.9997) and high inter-rater reliability (ICC 0.99994). Analysiswith Bland Altman plots showed the mean bias for both intra- and inter-rater reliability to be close to zero with acceptable limitsof agreement. Conclusions: This study has shown that liver volume measurements using the Philips SAIP (Endhoven, The Netherlands) can betaken reliably by CT technologists, with confidence that the same results would be obtained between different CT technologists.