{"title":"青少年女排运动员动态平衡测试:发展、可靠性与实用性","authors":"Karla Dolo, Z. Grgantov, Igor Jelaska","doi":"10.5114/hm.2023.116635","DOIUrl":null,"url":null,"abstract":"Purpose. the aim of this research was to develop a dynamic balance test and examine its reliability by comparing first trial results with the average and best ones from multiple attempts. Methods. Overall, 32 volleyball players (aged 11.3 ± 0.67 years) were investigated in 2 sessions (with a 14-day interval), each consisting of 3 trials of the modified bench walk with 3 turns (MBW3t) test. three test methods were compared: first trial (MBW3t trial1 ), average result (MBW3t mean ), and best result (MBW3t best ). A paired-sample t -test determined differences with an effect size. test-retest reliability was assessed with an intraclass correlation coefficient. Results. the paired-sample t -test revealed no significant difference in performance between test and retest for MBW3t trial1 ( t = 0.01, p = 0.99), MBW3t mean ( t = –0.46, p = 0.65), and MBW3t best ( t = –1.05, p = 0.30). Standard error of measurement (SEM) as the absolute reliability within-individual variation parameter showed that MBW3t trial1 had higher variation than MBW3t mean and MBW3t best , in which the measurement error was minimal. to identify usefulness, we calculated the smallest worthwhile change and compared it with SEM for different effect sizes; the test was rated marginal to satisfactory. the study results indicated fair reliability when the first trial was observed and good reliability for the mean and best of 3 trials. Conclusions. MBW3t mean and MBW3t best are cheap, simple, reliable, and marginal to satisfactory useful measures for assessing dynamic balance in youth female volleyball players and can be used in scientific and practical settings.","PeriodicalId":35354,"journal":{"name":"Human Movement","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Testing dynamic balance in youth female volleyball players: development, reliability and usefulness\",\"authors\":\"Karla Dolo, Z. Grgantov, Igor Jelaska\",\"doi\":\"10.5114/hm.2023.116635\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Purpose. the aim of this research was to develop a dynamic balance test and examine its reliability by comparing first trial results with the average and best ones from multiple attempts. Methods. Overall, 32 volleyball players (aged 11.3 ± 0.67 years) were investigated in 2 sessions (with a 14-day interval), each consisting of 3 trials of the modified bench walk with 3 turns (MBW3t) test. three test methods were compared: first trial (MBW3t trial1 ), average result (MBW3t mean ), and best result (MBW3t best ). A paired-sample t -test determined differences with an effect size. test-retest reliability was assessed with an intraclass correlation coefficient. Results. the paired-sample t -test revealed no significant difference in performance between test and retest for MBW3t trial1 ( t = 0.01, p = 0.99), MBW3t mean ( t = –0.46, p = 0.65), and MBW3t best ( t = –1.05, p = 0.30). Standard error of measurement (SEM) as the absolute reliability within-individual variation parameter showed that MBW3t trial1 had higher variation than MBW3t mean and MBW3t best , in which the measurement error was minimal. to identify usefulness, we calculated the smallest worthwhile change and compared it with SEM for different effect sizes; the test was rated marginal to satisfactory. the study results indicated fair reliability when the first trial was observed and good reliability for the mean and best of 3 trials. Conclusions. MBW3t mean and MBW3t best are cheap, simple, reliable, and marginal to satisfactory useful measures for assessing dynamic balance in youth female volleyball players and can be used in scientific and practical settings.\",\"PeriodicalId\":35354,\"journal\":{\"name\":\"Human Movement\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Human Movement\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5114/hm.2023.116635\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Health Professions\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Human Movement","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5114/hm.2023.116635","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Health Professions","Score":null,"Total":0}
引用次数: 0
摘要
目的。本研究的目的是开发一种动态平衡测试,并通过将首次试验结果与多次试验的平均和最佳结果进行比较,来检验其可靠性。方法。本研究共对32名排球运动员(年龄11.3±0.67岁)进行了2期(间隔14天)的调查,每期包括3次改良台式行走3圈(MBW3t)测试。比较三种试验方法:首次试验(MBW3t trial1)、平均结果(MBW3t mean)和最佳结果(MBW3t best)。配对样本t检验以效应大小确定差异。用类内相关系数评估重测信度。结果。配对样本t检验显示,MBW3t试验1 (t = 0.01, p = 0.99)、MBW3t均值(t = -0.46, p = 0.65)和MBW3t最佳(t = -1.05, p = 0.30)的测试与重测结果无显著差异。测量标准误差(SEM)作为个体内变异的绝对信度参数,表明MBW3t试验1的变异高于MBW3t均值和MBW3t最佳,其中测量误差最小。为了确定有用性,我们计算了最小的有价值的变化,并将其与不同效应大小的SEM进行了比较;该试验被评为勉强及格。研究结果表明,第一次试验的信度尚可,3次试验的均值和最佳信度良好。结论。MBW3t mean和MBW3t best是一种廉价、简单、可靠、边际满意的评价青少年女排运动员动态平衡的有效方法,具有一定的科学和实用价值。
Testing dynamic balance in youth female volleyball players: development, reliability and usefulness
Purpose. the aim of this research was to develop a dynamic balance test and examine its reliability by comparing first trial results with the average and best ones from multiple attempts. Methods. Overall, 32 volleyball players (aged 11.3 ± 0.67 years) were investigated in 2 sessions (with a 14-day interval), each consisting of 3 trials of the modified bench walk with 3 turns (MBW3t) test. three test methods were compared: first trial (MBW3t trial1 ), average result (MBW3t mean ), and best result (MBW3t best ). A paired-sample t -test determined differences with an effect size. test-retest reliability was assessed with an intraclass correlation coefficient. Results. the paired-sample t -test revealed no significant difference in performance between test and retest for MBW3t trial1 ( t = 0.01, p = 0.99), MBW3t mean ( t = –0.46, p = 0.65), and MBW3t best ( t = –1.05, p = 0.30). Standard error of measurement (SEM) as the absolute reliability within-individual variation parameter showed that MBW3t trial1 had higher variation than MBW3t mean and MBW3t best , in which the measurement error was minimal. to identify usefulness, we calculated the smallest worthwhile change and compared it with SEM for different effect sizes; the test was rated marginal to satisfactory. the study results indicated fair reliability when the first trial was observed and good reliability for the mean and best of 3 trials. Conclusions. MBW3t mean and MBW3t best are cheap, simple, reliable, and marginal to satisfactory useful measures for assessing dynamic balance in youth female volleyball players and can be used in scientific and practical settings.