在模拟弯曲根管中使用手k锉和旋转路径锉制备滑动路径:一项体外研究

Miljan Stošić, Katarina Geler, Violeta Petrović, Milica Jovanovic-Medojevic
{"title":"在模拟弯曲根管中使用手k锉和旋转路径锉制备滑动路径:一项体外研究","authors":"Miljan Stošić, Katarina Geler, Violeta Petrović, Milica Jovanovic-Medojevic","doi":"10.5937/mp74-39415","DOIUrl":null,"url":null,"abstract":"Introduction: Preparation of glide path is an important precondition for the safe use of rotary NiTi instruments during endodontic treatment. Aim: The aim of this study was to examine the duration of glide path preparation as well as all the changes in canal morphology and canal diameter after the use of hand K-files and NiTi rotary PathFiles. Material and methods: This research was performed on a total of twenty Endo Training Blocks (Dentsply, Maillefer, Switzerland). The glide path was prepared using hand stainless steel K-files ISO #10-15-20 (Dentsply, Sirona, USA) (n = 10) and NiTi rotary PathFiles ISO #13, #16 and #19 (Dentsply, Sirona, Switzerland) (n = 10). The time required to establish the glide path was measured with an iPhone stopwatch (Apple Inc. Cupertino, California). The images of the apical segment of canals before and after glide path preparation were taken under the stereomicroscope (Boeco BSZ-405, Germany), and then images were analyzed and processed with Scopeimage 9.0 (Teleskop, Austria). Statistical analysis was performed with the Mann-Whitney test at the level of significance 5% (a = 0.05). Results: A statistically significant difference was observed in terms of the time required for glide path preparation. The mean total time for glide path preparation was significantly longer with K-files (382 ± 62 s) than with PathFile (200 ± 11 s) (p < 0.05). A statistically significant difference in terms of changing the morphology of the apical part of the canal (p > 0.05) was not observed. The difference in the diameter of the root canal was at the limit of statistical significance (p ≈ 0.05). Conclusion: Instrumentation with NiTi rotary PathFiles reduces the time required for glide path preparation. Preparing endodontic space for rotary instrumentation with hand K-Files and rotary PathFiles leads to similar changes in the morphology of the apical segment. A slightly larger diameter of the root canal was measured after preparation with the hand K-files.","PeriodicalId":31558,"journal":{"name":"Medicinski Podmladak","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Glide path preparation with hand K-files and rotary PathFiles in simulated curved root canals: An in vitro study\",\"authors\":\"Miljan Stošić, Katarina Geler, Violeta Petrović, Milica Jovanovic-Medojevic\",\"doi\":\"10.5937/mp74-39415\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction: Preparation of glide path is an important precondition for the safe use of rotary NiTi instruments during endodontic treatment. Aim: The aim of this study was to examine the duration of glide path preparation as well as all the changes in canal morphology and canal diameter after the use of hand K-files and NiTi rotary PathFiles. Material and methods: This research was performed on a total of twenty Endo Training Blocks (Dentsply, Maillefer, Switzerland). The glide path was prepared using hand stainless steel K-files ISO #10-15-20 (Dentsply, Sirona, USA) (n = 10) and NiTi rotary PathFiles ISO #13, #16 and #19 (Dentsply, Sirona, Switzerland) (n = 10). The time required to establish the glide path was measured with an iPhone stopwatch (Apple Inc. Cupertino, California). The images of the apical segment of canals before and after glide path preparation were taken under the stereomicroscope (Boeco BSZ-405, Germany), and then images were analyzed and processed with Scopeimage 9.0 (Teleskop, Austria). Statistical analysis was performed with the Mann-Whitney test at the level of significance 5% (a = 0.05). Results: A statistically significant difference was observed in terms of the time required for glide path preparation. The mean total time for glide path preparation was significantly longer with K-files (382 ± 62 s) than with PathFile (200 ± 11 s) (p < 0.05). A statistically significant difference in terms of changing the morphology of the apical part of the canal (p > 0.05) was not observed. The difference in the diameter of the root canal was at the limit of statistical significance (p ≈ 0.05). Conclusion: Instrumentation with NiTi rotary PathFiles reduces the time required for glide path preparation. Preparing endodontic space for rotary instrumentation with hand K-Files and rotary PathFiles leads to similar changes in the morphology of the apical segment. A slightly larger diameter of the root canal was measured after preparation with the hand K-files.\",\"PeriodicalId\":31558,\"journal\":{\"name\":\"Medicinski Podmladak\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Medicinski Podmladak\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5937/mp74-39415\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medicinski Podmladak","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5937/mp74-39415","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

滑梯的准备是根管治疗中旋转NiTi器械安全使用的重要前提。目的:本研究的目的是检查滑行道准备时间,以及使用手k锉和NiTi旋转路径锉后管形态和管径的所有变化。材料和方法:本研究在总共20个Endo训练块(Dentsply, Maillefer, Switzerland)上进行。使用手动不锈钢k形锉ISO #10-15-20 (Dentsply, Sirona, USA) (n = 10)和NiTi旋转PathFiles ISO #13、#16和#19 (Dentsply, Sirona, Switzerland) (n = 10)制备滑翔路径。建立下滑路径所需的时间是用苹果公司(Apple Inc.)的iPhone秒表测量的。加州库比蒂诺市)。在立体显微镜(Boeco BSZ-405,德国)下拍摄滑行道制备前后的根管根尖段图像,并用Scopeimage 9.0 (Teleskop,奥地利)软件对图像进行分析和处理。统计学分析采用Mann-Whitney检验,显著性水平为5% (a = 0.05)。结果:在滑行路径准备所需的时间方面,观察到有统计学意义的差异。K-files组滑翔路径准备的平均总时间(382±62 s)明显长于PathFile组(200±11 s) (p < 0.05)。在改变根管根尖部分形态方面,差异无统计学意义(p < 0.05)。根管直径差异有统计学意义(p≈0.05)。结论:NiTi旋转路径文件的仪器减少了滑翔路径准备所需的时间。用手K-Files和旋转PathFiles为旋转器械准备根管空间会导致根尖段形态的类似变化。预备后用手k锉测量根管直径稍大的根管。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Glide path preparation with hand K-files and rotary PathFiles in simulated curved root canals: An in vitro study
Introduction: Preparation of glide path is an important precondition for the safe use of rotary NiTi instruments during endodontic treatment. Aim: The aim of this study was to examine the duration of glide path preparation as well as all the changes in canal morphology and canal diameter after the use of hand K-files and NiTi rotary PathFiles. Material and methods: This research was performed on a total of twenty Endo Training Blocks (Dentsply, Maillefer, Switzerland). The glide path was prepared using hand stainless steel K-files ISO #10-15-20 (Dentsply, Sirona, USA) (n = 10) and NiTi rotary PathFiles ISO #13, #16 and #19 (Dentsply, Sirona, Switzerland) (n = 10). The time required to establish the glide path was measured with an iPhone stopwatch (Apple Inc. Cupertino, California). The images of the apical segment of canals before and after glide path preparation were taken under the stereomicroscope (Boeco BSZ-405, Germany), and then images were analyzed and processed with Scopeimage 9.0 (Teleskop, Austria). Statistical analysis was performed with the Mann-Whitney test at the level of significance 5% (a = 0.05). Results: A statistically significant difference was observed in terms of the time required for glide path preparation. The mean total time for glide path preparation was significantly longer with K-files (382 ± 62 s) than with PathFile (200 ± 11 s) (p < 0.05). A statistically significant difference in terms of changing the morphology of the apical part of the canal (p > 0.05) was not observed. The difference in the diameter of the root canal was at the limit of statistical significance (p ≈ 0.05). Conclusion: Instrumentation with NiTi rotary PathFiles reduces the time required for glide path preparation. Preparing endodontic space for rotary instrumentation with hand K-Files and rotary PathFiles leads to similar changes in the morphology of the apical segment. A slightly larger diameter of the root canal was measured after preparation with the hand K-files.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
1
审稿时长
4 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信