{"title":"基于聚甲基丙烯酸甲酯-丙烯酸丁酯(MB28)薄膜光聚合物和铅笔石墨电极的铅离子选择性电极(Pb-ISE)的制备","authors":"A. Ariri, S. Alva, D. S. Khaerudini, A. A. Aziz","doi":"10.4152/pea.2022400405","DOIUrl":null,"url":null,"abstract":"The purpose of this study was to fabricate lead ion selective electrode (Pb-ISE) sensors based on a 2:8 ratio of methyl-methacrylate-co-butyl acrylate thin film copolymers (MB28). These sensors were prepared by using a photo-polymerization technique on a pencil graphite electrode (PGE), with a poly-pyrrole-Cl (p-Py-Cl) thin film as a sensor transducer. During the Pb-ISE sensor fabrication process, the membrane composition optimization process has been carried out. The best sensor composition contained 1 mg potassium tetrakis (4-chlorophenyl) borate (KTpClPB) and 4.3 mg Pb ionophore IV. The fabricated Pb-ISE had a Nernstian number of 28.2 ± 0.5 mV/dec, a broad linear range from 10 -3 to 10 -10 M and a limit of detection (LOD) of (6.6 ± 1.6) x 10 -11 M, providing an excellent performance. In addition, the sensor showed a fairly good coefficient of effectiveness (CE) (Log K pota,b ) against K + (potassium), Na + (sodium), NH 4+ (ammonium), Mg 2+ (magnesium), Cu 2+ (copper) and Cd 2+ (cadmium) cations, which were -6.6 ± 0.2, -6.1 ± 0.2, -6.7 ± 0.2, -12.4 ± 0.3, -4.4 ± 0.2 and -6.1 ± 0.1, respectively. The Pb-ISE sensor worked best in the pH range from 3 to 8. The validation process has been carried out by comparing the measurements results of the artificial samples, at the concentrations from 25 to 100 ppm, with those of the real sample from Angke river water. The outcome was outstanding and comparable to that of the standard UV-Vis spectrophotometry measurement methods.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Fabrication of Lead Ion Selective Electrodes (Pb-ISE) based on Poly Methyl-Methacrylate-Co-Butyl Acrylate (MB28) Thin Film Photo-polymers and Pencil Graphite Electrodes (PGEs)\",\"authors\":\"A. Ariri, S. Alva, D. S. Khaerudini, A. A. Aziz\",\"doi\":\"10.4152/pea.2022400405\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The purpose of this study was to fabricate lead ion selective electrode (Pb-ISE) sensors based on a 2:8 ratio of methyl-methacrylate-co-butyl acrylate thin film copolymers (MB28). These sensors were prepared by using a photo-polymerization technique on a pencil graphite electrode (PGE), with a poly-pyrrole-Cl (p-Py-Cl) thin film as a sensor transducer. During the Pb-ISE sensor fabrication process, the membrane composition optimization process has been carried out. The best sensor composition contained 1 mg potassium tetrakis (4-chlorophenyl) borate (KTpClPB) and 4.3 mg Pb ionophore IV. The fabricated Pb-ISE had a Nernstian number of 28.2 ± 0.5 mV/dec, a broad linear range from 10 -3 to 10 -10 M and a limit of detection (LOD) of (6.6 ± 1.6) x 10 -11 M, providing an excellent performance. In addition, the sensor showed a fairly good coefficient of effectiveness (CE) (Log K pota,b ) against K + (potassium), Na + (sodium), NH 4+ (ammonium), Mg 2+ (magnesium), Cu 2+ (copper) and Cd 2+ (cadmium) cations, which were -6.6 ± 0.2, -6.1 ± 0.2, -6.7 ± 0.2, -12.4 ± 0.3, -4.4 ± 0.2 and -6.1 ± 0.1, respectively. The Pb-ISE sensor worked best in the pH range from 3 to 8. The validation process has been carried out by comparing the measurements results of the artificial samples, at the concentrations from 25 to 100 ppm, with those of the real sample from Angke river water. The outcome was outstanding and comparable to that of the standard UV-Vis spectrophotometry measurement methods.\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4152/pea.2022400405\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4152/pea.2022400405","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Fabrication of Lead Ion Selective Electrodes (Pb-ISE) based on Poly Methyl-Methacrylate-Co-Butyl Acrylate (MB28) Thin Film Photo-polymers and Pencil Graphite Electrodes (PGEs)
The purpose of this study was to fabricate lead ion selective electrode (Pb-ISE) sensors based on a 2:8 ratio of methyl-methacrylate-co-butyl acrylate thin film copolymers (MB28). These sensors were prepared by using a photo-polymerization technique on a pencil graphite electrode (PGE), with a poly-pyrrole-Cl (p-Py-Cl) thin film as a sensor transducer. During the Pb-ISE sensor fabrication process, the membrane composition optimization process has been carried out. The best sensor composition contained 1 mg potassium tetrakis (4-chlorophenyl) borate (KTpClPB) and 4.3 mg Pb ionophore IV. The fabricated Pb-ISE had a Nernstian number of 28.2 ± 0.5 mV/dec, a broad linear range from 10 -3 to 10 -10 M and a limit of detection (LOD) of (6.6 ± 1.6) x 10 -11 M, providing an excellent performance. In addition, the sensor showed a fairly good coefficient of effectiveness (CE) (Log K pota,b ) against K + (potassium), Na + (sodium), NH 4+ (ammonium), Mg 2+ (magnesium), Cu 2+ (copper) and Cd 2+ (cadmium) cations, which were -6.6 ± 0.2, -6.1 ± 0.2, -6.7 ± 0.2, -12.4 ± 0.3, -4.4 ± 0.2 and -6.1 ± 0.1, respectively. The Pb-ISE sensor worked best in the pH range from 3 to 8. The validation process has been carried out by comparing the measurements results of the artificial samples, at the concentrations from 25 to 100 ppm, with those of the real sample from Angke river water. The outcome was outstanding and comparable to that of the standard UV-Vis spectrophotometry measurement methods.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.