F. Sabzi, A. Zokaei, Abdolrasoul Moloudi, S. Dabiri
{"title":"非动脉粥样硬化性髂总动脉内球囊泵夹持","authors":"F. Sabzi, A. Zokaei, Abdolrasoul Moloudi, S. Dabiri","doi":"10.4137/OJCS.S7688","DOIUrl":null,"url":null,"abstract":"Use of an intra-aortic balloon pump (IABP) is helpful for maintaining hemodynamic stability in patients with low cardiac output and compromised left ventricular function undergoing coronary artery bypass grafting. Although the incidence of complications has decreased significantly as experience with the device has increased, IABP use still carries a risk of complications. The most common complication is limb ischemia, mainly as a result of IABP entrapment and thromboembolism. Here we report a case of IABP entrapment in a nonatherosclerotic common iliac artery where forced removal caused fracture of the catheter.","PeriodicalId":90668,"journal":{"name":"Open journal of cardiovascular surgery","volume":"4 1","pages":"5 - 7"},"PeriodicalIF":0.0000,"publicationDate":"2011-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.4137/OJCS.S7688","citationCount":"4","resultStr":"{\"title\":\"Intra-Aortic Balloon Pump Entrapment in a Nonatherosclerotic Common Iliac Artery\",\"authors\":\"F. Sabzi, A. Zokaei, Abdolrasoul Moloudi, S. Dabiri\",\"doi\":\"10.4137/OJCS.S7688\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Use of an intra-aortic balloon pump (IABP) is helpful for maintaining hemodynamic stability in patients with low cardiac output and compromised left ventricular function undergoing coronary artery bypass grafting. Although the incidence of complications has decreased significantly as experience with the device has increased, IABP use still carries a risk of complications. The most common complication is limb ischemia, mainly as a result of IABP entrapment and thromboembolism. Here we report a case of IABP entrapment in a nonatherosclerotic common iliac artery where forced removal caused fracture of the catheter.\",\"PeriodicalId\":90668,\"journal\":{\"name\":\"Open journal of cardiovascular surgery\",\"volume\":\"4 1\",\"pages\":\"5 - 7\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.4137/OJCS.S7688\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Open journal of cardiovascular surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4137/OJCS.S7688\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Open journal of cardiovascular surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4137/OJCS.S7688","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Intra-Aortic Balloon Pump Entrapment in a Nonatherosclerotic Common Iliac Artery
Use of an intra-aortic balloon pump (IABP) is helpful for maintaining hemodynamic stability in patients with low cardiac output and compromised left ventricular function undergoing coronary artery bypass grafting. Although the incidence of complications has decreased significantly as experience with the device has increased, IABP use still carries a risk of complications. The most common complication is limb ischemia, mainly as a result of IABP entrapment and thromboembolism. Here we report a case of IABP entrapment in a nonatherosclerotic common iliac artery where forced removal caused fracture of the catheter.