{"title":"静止状态心动过缓患者双传感器心脏起搏器系统的模糊控制","authors":"Basil Hamed, A. Ras","doi":"10.4236/ICA.2015.63016","DOIUrl":null,"url":null,"abstract":"Cardiovascular \ndisease is defined as a heart rate that is less than 60 bpm. Implantable \ncardiac devices such as pacemakers are widely used nowadays. In this paper, design and implementation of \nthe heart model can be controlled to be the heart of a patient suffering from a \ndecrease in heart rate (Bradycardia). A system is designed to sense and calculate \nthe heart rate per minute and it is considered as an input to the controller. \nThe design and implementation of Mamdani fuzzy controller to \ngenerate electric pulses that mimic the natural pacing system of the heart \nmaintains an adequate heart rate by delivering controlled, rhythmic electrical \nstimuli to the chambers of the patient heart. The proposed controller is tested by using \nMatlab/Simulink program.","PeriodicalId":62904,"journal":{"name":"智能控制与自动化(英文)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2015-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Fuzzy Controller for Dual Sensors Cardiac Pacemaker System in Patients with Bradycardias at Rest\",\"authors\":\"Basil Hamed, A. Ras\",\"doi\":\"10.4236/ICA.2015.63016\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Cardiovascular \\ndisease is defined as a heart rate that is less than 60 bpm. Implantable \\ncardiac devices such as pacemakers are widely used nowadays. In this paper, design and implementation of \\nthe heart model can be controlled to be the heart of a patient suffering from a \\ndecrease in heart rate (Bradycardia). A system is designed to sense and calculate \\nthe heart rate per minute and it is considered as an input to the controller. \\nThe design and implementation of Mamdani fuzzy controller to \\ngenerate electric pulses that mimic the natural pacing system of the heart \\nmaintains an adequate heart rate by delivering controlled, rhythmic electrical \\nstimuli to the chambers of the patient heart. The proposed controller is tested by using \\nMatlab/Simulink program.\",\"PeriodicalId\":62904,\"journal\":{\"name\":\"智能控制与自动化(英文)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-07-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"智能控制与自动化(英文)\",\"FirstCategoryId\":\"1093\",\"ListUrlMain\":\"https://doi.org/10.4236/ICA.2015.63016\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"智能控制与自动化(英文)","FirstCategoryId":"1093","ListUrlMain":"https://doi.org/10.4236/ICA.2015.63016","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Fuzzy Controller for Dual Sensors Cardiac Pacemaker System in Patients with Bradycardias at Rest
Cardiovascular
disease is defined as a heart rate that is less than 60 bpm. Implantable
cardiac devices such as pacemakers are widely used nowadays. In this paper, design and implementation of
the heart model can be controlled to be the heart of a patient suffering from a
decrease in heart rate (Bradycardia). A system is designed to sense and calculate
the heart rate per minute and it is considered as an input to the controller.
The design and implementation of Mamdani fuzzy controller to
generate electric pulses that mimic the natural pacing system of the heart
maintains an adequate heart rate by delivering controlled, rhythmic electrical
stimuli to the chambers of the patient heart. The proposed controller is tested by using
Matlab/Simulink program.