M. Akino, S. Yamamoto, Satoshi Saikawa, Masako Satoh, Kimiko Segawa, K. Kobayashi, K. Ikebuchi, H. Ikeda
{"title":"用IN-LIN全血过滤系统减少储存前白细胞:系统效率和血液制品的评价","authors":"M. Akino, S. Yamamoto, Satoshi Saikawa, Masako Satoh, Kimiko Segawa, K. Kobayashi, K. Ikebuchi, H. Ikeda","doi":"10.3925/jjtc1958.46.521","DOIUrl":null,"url":null,"abstract":"Anewly developed leukoreduction filter system for whole blood was evaluated. Whole blood was leukoreduced with the closed system(Sepacell Integra MAP), followed by centrifugation to obtain red cells and plasma(Leukocyte-reduced plasma: LR-FFP). Red cells were reconstituted with MAP solution(Leukocyte-reduced RCC: LR-RCC). Residual leukocyte counts were 1.8±1.3×105/bag after filtration and O.9±0.5×105/bag in LRRCC. These values are well below those indicated in the AABB standard and CE guideline. Erythrocyte recovery rate in Sepacell MAP was 89.1±2.3%, which was not different from that in red cell concentrate without filtration(buffy coat reduced RCC: BCR-RCC). There was no accumulation of IL-1β, IL-80r LDH in the supernatants of LR-RCC during storage. Further, there was no significant difference in electrolyte levels in the supernatant and red cell fractions during storage between LR-RCC and BCR-RCC. In LR-FFP, elevation of C3a was observed in 2 0f 6 samples, while elevation of LDH was not observed.","PeriodicalId":86521,"journal":{"name":"Nihon Yuketsu Gakkai zasshi = Journal of the Japan Society of Blood Transfusion","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2010-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"PRESTORAGE LEUKOCYTE REDUCTION WITH IN-LIN FILTRATION SYSTEM FOR WHOLE BLOOD (Sepacell Integra MAP): EVALUATION OF SYSTEM EFFICIENCY AND BLOOD PRODUCTS\",\"authors\":\"M. Akino, S. Yamamoto, Satoshi Saikawa, Masako Satoh, Kimiko Segawa, K. Kobayashi, K. Ikebuchi, H. Ikeda\",\"doi\":\"10.3925/jjtc1958.46.521\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Anewly developed leukoreduction filter system for whole blood was evaluated. Whole blood was leukoreduced with the closed system(Sepacell Integra MAP), followed by centrifugation to obtain red cells and plasma(Leukocyte-reduced plasma: LR-FFP). Red cells were reconstituted with MAP solution(Leukocyte-reduced RCC: LR-RCC). Residual leukocyte counts were 1.8±1.3×105/bag after filtration and O.9±0.5×105/bag in LRRCC. These values are well below those indicated in the AABB standard and CE guideline. Erythrocyte recovery rate in Sepacell MAP was 89.1±2.3%, which was not different from that in red cell concentrate without filtration(buffy coat reduced RCC: BCR-RCC). There was no accumulation of IL-1β, IL-80r LDH in the supernatants of LR-RCC during storage. Further, there was no significant difference in electrolyte levels in the supernatant and red cell fractions during storage between LR-RCC and BCR-RCC. In LR-FFP, elevation of C3a was observed in 2 0f 6 samples, while elevation of LDH was not observed.\",\"PeriodicalId\":86521,\"journal\":{\"name\":\"Nihon Yuketsu Gakkai zasshi = Journal of the Japan Society of Blood Transfusion\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nihon Yuketsu Gakkai zasshi = Journal of the Japan Society of Blood Transfusion\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3925/jjtc1958.46.521\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nihon Yuketsu Gakkai zasshi = Journal of the Japan Society of Blood Transfusion","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3925/jjtc1958.46.521","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
PRESTORAGE LEUKOCYTE REDUCTION WITH IN-LIN FILTRATION SYSTEM FOR WHOLE BLOOD (Sepacell Integra MAP): EVALUATION OF SYSTEM EFFICIENCY AND BLOOD PRODUCTS
Anewly developed leukoreduction filter system for whole blood was evaluated. Whole blood was leukoreduced with the closed system(Sepacell Integra MAP), followed by centrifugation to obtain red cells and plasma(Leukocyte-reduced plasma: LR-FFP). Red cells were reconstituted with MAP solution(Leukocyte-reduced RCC: LR-RCC). Residual leukocyte counts were 1.8±1.3×105/bag after filtration and O.9±0.5×105/bag in LRRCC. These values are well below those indicated in the AABB standard and CE guideline. Erythrocyte recovery rate in Sepacell MAP was 89.1±2.3%, which was not different from that in red cell concentrate without filtration(buffy coat reduced RCC: BCR-RCC). There was no accumulation of IL-1β, IL-80r LDH in the supernatants of LR-RCC during storage. Further, there was no significant difference in electrolyte levels in the supernatant and red cell fractions during storage between LR-RCC and BCR-RCC. In LR-FFP, elevation of C3a was observed in 2 0f 6 samples, while elevation of LDH was not observed.