用于IBR-2反应堆高分辨率傅立叶衍射仪(HRFD)的大孔径后向散射探测器(BSD)

IF 1 Q3 NUCLEAR SCIENCE & TECHNOLOGY
V. Kruglov, A. Balagurov, M. Belova, I. Bobrikov, A. Bogdzel’, V. Bodnarchuk, V. V. Bulavina, O. Daulbaev, V. Drozdov, V. Zhuravlev, A. Kirilov, S. Kulikov, A. K. Kurilkin, V. Milkov, S. Murashkevich, M. M. Podlesnyy, V. I. Prikhod’ko, A. Churakov, V. Shvetsov
{"title":"用于IBR-2反应堆高分辨率傅立叶衍射仪(HRFD)的大孔径后向散射探测器(BSD)","authors":"V. Kruglov, A. Balagurov, M. Belova, I. Bobrikov, A. Bogdzel’, V. Bodnarchuk, V. V. Bulavina, O. Daulbaev, V. Drozdov, V. Zhuravlev, A. Kirilov, S. Kulikov, A. K. Kurilkin, V. Milkov, S. Murashkevich, M. M. Podlesnyy, V. I. Prikhod’ko, A. Churakov, V. Shvetsov","doi":"10.3233/jnr-210001","DOIUrl":null,"url":null,"abstract":"The high-resolution Fourier diffractometer (HRFD) operates at the IBR-2 pulsed reactor, on which the correlation method of data registering has been implemented using a fast Fourier chopper and specialized electronics. A wide-aperture ring back-scattering detector for HRFD has been developed. The detector consists of six Z n S ( A g ) / 6 L i F-scintillation rings, each one of which is divided into 12 sections. Main parameters of this detector: covered solid angle 2 θ = ( 133 − 175 ) ∘ ; Ω d ≈ 2.0 sr; average absorption efficiency 85 %, geometric contribution to resolution Δ d / d < 0.0005. The concept of a detector and its data acquisition system are presented.","PeriodicalId":44708,"journal":{"name":"Journal of Neutron Research","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3233/jnr-210001","citationCount":"0","resultStr":"{\"title\":\"Wide-aperture back-scattering detector (BSD) for the High-Resolution Fourier Diffractometer (HRFD) at the IBR-2 reactor\",\"authors\":\"V. Kruglov, A. Balagurov, M. Belova, I. Bobrikov, A. Bogdzel’, V. Bodnarchuk, V. V. Bulavina, O. Daulbaev, V. Drozdov, V. Zhuravlev, A. Kirilov, S. Kulikov, A. K. Kurilkin, V. Milkov, S. Murashkevich, M. M. Podlesnyy, V. I. Prikhod’ko, A. Churakov, V. Shvetsov\",\"doi\":\"10.3233/jnr-210001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The high-resolution Fourier diffractometer (HRFD) operates at the IBR-2 pulsed reactor, on which the correlation method of data registering has been implemented using a fast Fourier chopper and specialized electronics. A wide-aperture ring back-scattering detector for HRFD has been developed. The detector consists of six Z n S ( A g ) / 6 L i F-scintillation rings, each one of which is divided into 12 sections. Main parameters of this detector: covered solid angle 2 θ = ( 133 − 175 ) ∘ ; Ω d ≈ 2.0 sr; average absorption efficiency 85 %, geometric contribution to resolution Δ d / d < 0.0005. The concept of a detector and its data acquisition system are presented.\",\"PeriodicalId\":44708,\"journal\":{\"name\":\"Journal of Neutron Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2021-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3233/jnr-210001\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Neutron Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3233/jnr-210001\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"NUCLEAR SCIENCE & TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Neutron Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3233/jnr-210001","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"NUCLEAR SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

高分辨率傅立叶衍射仪(HRFD)工作在IBR-2脉冲反应堆上,利用快速傅立叶斩波器和专用电子器件实现了数据记录的相关方法。研制了一种用于HRFD的大孔径环形后向散射探测器。探测器由6个Z n S (A g) / 6 L i f闪烁环组成,每个闪烁环分为12个部分。本探测器主要参数:覆盖立体角2 θ =(133−175)°;Ω d≈2.0 sr;平均吸收效率85%,对分辨率的几何贡献Δ d / d < 0.0005。提出了探测器及其数据采集系统的概念。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Wide-aperture back-scattering detector (BSD) for the High-Resolution Fourier Diffractometer (HRFD) at the IBR-2 reactor
The high-resolution Fourier diffractometer (HRFD) operates at the IBR-2 pulsed reactor, on which the correlation method of data registering has been implemented using a fast Fourier chopper and specialized electronics. A wide-aperture ring back-scattering detector for HRFD has been developed. The detector consists of six Z n S ( A g ) / 6 L i F-scintillation rings, each one of which is divided into 12 sections. Main parameters of this detector: covered solid angle 2 θ = ( 133 − 175 ) ∘ ; Ω d ≈ 2.0 sr; average absorption efficiency 85 %, geometric contribution to resolution Δ d / d < 0.0005. The concept of a detector and its data acquisition system are presented.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Neutron Research
Journal of Neutron Research NUCLEAR SCIENCE & TECHNOLOGY-
CiteScore
2.30
自引率
9.10%
发文量
23
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信