{"title":"高速铁路受电弓-接触网电弧试验系统","authors":"Wang Wangang, Wu Guangning, Gao Guoqiang, Wang Bo, Cui Yi, Liu Donglai","doi":"10.3969/J.ISSN.1001-8360.2012.04.004","DOIUrl":null,"url":null,"abstract":"High speed electric multi units (EMU) get power through pantograph-centenary electrical contact. As the EMU running velocity increases, rail surface irregularities, undulations of the catenary and vibrations of the pantograph head cause the status of pantograph-centenary electrical contact to deteriorate seriously and generate pantograph-catenary arcs frequently. The arcs erode the contact wire and pantograph strip, endanger the current-receiving quality between pantograph and catenary and restrain further raizing of the EMU speed. So it is very important to study the pantograph-catenary arcs. In this paper, the pantograph-catenary current-receiving process was analyzed. The pantograph-catenary arc test system was developed, which simulated the flexible and straight contact of pantograph and contact wire, pantograph strip zigzag movements and vertical up and down movements of the pantograph. The test system was used to study, the pantograph-catenary contact resistance, and the electrical parameters and shape features of the arcs.","PeriodicalId":35766,"journal":{"name":"铁道学报","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2012-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":"{\"title\":\"The Pantograph-catenary Arc Test system for High-speed Railways\",\"authors\":\"Wang Wangang, Wu Guangning, Gao Guoqiang, Wang Bo, Cui Yi, Liu Donglai\",\"doi\":\"10.3969/J.ISSN.1001-8360.2012.04.004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"High speed electric multi units (EMU) get power through pantograph-centenary electrical contact. As the EMU running velocity increases, rail surface irregularities, undulations of the catenary and vibrations of the pantograph head cause the status of pantograph-centenary electrical contact to deteriorate seriously and generate pantograph-catenary arcs frequently. The arcs erode the contact wire and pantograph strip, endanger the current-receiving quality between pantograph and catenary and restrain further raizing of the EMU speed. So it is very important to study the pantograph-catenary arcs. In this paper, the pantograph-catenary current-receiving process was analyzed. The pantograph-catenary arc test system was developed, which simulated the flexible and straight contact of pantograph and contact wire, pantograph strip zigzag movements and vertical up and down movements of the pantograph. The test system was used to study, the pantograph-catenary contact resistance, and the electrical parameters and shape features of the arcs.\",\"PeriodicalId\":35766,\"journal\":{\"name\":\"铁道学报\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"12\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"铁道学报\",\"FirstCategoryId\":\"1087\",\"ListUrlMain\":\"https://doi.org/10.3969/J.ISSN.1001-8360.2012.04.004\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"铁道学报","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.3969/J.ISSN.1001-8360.2012.04.004","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 12

摘要

高速电动车组(EMU)通过受电弓-百年电接点获得动力。随着动车组运行速度的提高,钢轨表面的不规则性、接触网的波动和受电弓头部的振动导致受电弓-接触网电接触状况严重恶化,经常产生受电弓-接触网电弧。电弧腐蚀触线和受电弓带,影响受电弓与接触网之间的电流接收质量,制约动车组速度的进一步提高。因此,对受电弓接触网弧的研究具有十分重要的意义。本文分析了受电弓-接触网接受电流的过程。开发了受电弓-接触网电弧测试系统,模拟了受电弓与接触线的柔性直接触、受电弓条之字形运动和受电弓的垂直上下运动。利用该测试系统对受电弓接触网接触电阻、电弧的电学参数和形状特征进行了研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Pantograph-catenary Arc Test system for High-speed Railways
High speed electric multi units (EMU) get power through pantograph-centenary electrical contact. As the EMU running velocity increases, rail surface irregularities, undulations of the catenary and vibrations of the pantograph head cause the status of pantograph-centenary electrical contact to deteriorate seriously and generate pantograph-catenary arcs frequently. The arcs erode the contact wire and pantograph strip, endanger the current-receiving quality between pantograph and catenary and restrain further raizing of the EMU speed. So it is very important to study the pantograph-catenary arcs. In this paper, the pantograph-catenary current-receiving process was analyzed. The pantograph-catenary arc test system was developed, which simulated the flexible and straight contact of pantograph and contact wire, pantograph strip zigzag movements and vertical up and down movements of the pantograph. The test system was used to study, the pantograph-catenary contact resistance, and the electrical parameters and shape features of the arcs.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
铁道学报
铁道学报 Engineering-Mechanical Engineering
CiteScore
2.00
自引率
0.00%
发文量
6728
期刊介绍:
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信