Aitor Marcos-Blanco, F. García-Pinillos, Alejandro Molina-Molina, D. Jaén-Carrillo, V. Soto-Hermoso, Santiago A. Ruiz-Alias
{"title":"RunScribe™系统在不同速度下确定骨盆运动变量的可靠性","authors":"Aitor Marcos-Blanco, F. García-Pinillos, Alejandro Molina-Molina, D. Jaén-Carrillo, V. Soto-Hermoso, Santiago A. Ruiz-Alias","doi":"10.37190/abb-02073-2022-03","DOIUrl":null,"url":null,"abstract":"Purpose This study aimed to determine the reliability of the RunScribe™ system to measure kinematic variables of the pelvis during walking and running. Methods In this study, a treadmill protocol was implemented where the participants (n=23) completed 3 sets of 1 minute at 5, 10 and 15 km.h-1. Results All the recorded measurements during walking reported a low reliability with coefficients of variation (CV) greater than 10% in all variables and small-moderate intraclass correlation coefficient (ICC) (< 0.6) in seven out of ten variables. Similarly, the CVs reported in running were greater than 10% except for the maximum angular rate in the obliquity of the pelvis and the vertical oscillation that together with the angular velocity variables showed almost perfect ICCs (> 0.92). Conclusions Therefore, the data obtained suggests that the RunScribe™ system with 3 IMUs does not provide reliable metrics about the kinematics of the pelvis during locomotion (i.e., walking and running).","PeriodicalId":0,"journal":{"name":"","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reliability of the RunScribe™ system to determine kinematic variables of the pelvis during locomotion at different speeds\",\"authors\":\"Aitor Marcos-Blanco, F. García-Pinillos, Alejandro Molina-Molina, D. Jaén-Carrillo, V. Soto-Hermoso, Santiago A. Ruiz-Alias\",\"doi\":\"10.37190/abb-02073-2022-03\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Purpose This study aimed to determine the reliability of the RunScribe™ system to measure kinematic variables of the pelvis during walking and running. Methods In this study, a treadmill protocol was implemented where the participants (n=23) completed 3 sets of 1 minute at 5, 10 and 15 km.h-1. Results All the recorded measurements during walking reported a low reliability with coefficients of variation (CV) greater than 10% in all variables and small-moderate intraclass correlation coefficient (ICC) (< 0.6) in seven out of ten variables. Similarly, the CVs reported in running were greater than 10% except for the maximum angular rate in the obliquity of the pelvis and the vertical oscillation that together with the angular velocity variables showed almost perfect ICCs (> 0.92). Conclusions Therefore, the data obtained suggests that the RunScribe™ system with 3 IMUs does not provide reliable metrics about the kinematics of the pelvis during locomotion (i.e., walking and running).\",\"PeriodicalId\":0,\"journal\":{\"name\":\"\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.37190/abb-02073-2022-03\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.37190/abb-02073-2022-03","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Reliability of the RunScribe™ system to determine kinematic variables of the pelvis during locomotion at different speeds
Purpose This study aimed to determine the reliability of the RunScribe™ system to measure kinematic variables of the pelvis during walking and running. Methods In this study, a treadmill protocol was implemented where the participants (n=23) completed 3 sets of 1 minute at 5, 10 and 15 km.h-1. Results All the recorded measurements during walking reported a low reliability with coefficients of variation (CV) greater than 10% in all variables and small-moderate intraclass correlation coefficient (ICC) (< 0.6) in seven out of ten variables. Similarly, the CVs reported in running were greater than 10% except for the maximum angular rate in the obliquity of the pelvis and the vertical oscillation that together with the angular velocity variables showed almost perfect ICCs (> 0.92). Conclusions Therefore, the data obtained suggests that the RunScribe™ system with 3 IMUs does not provide reliable metrics about the kinematics of the pelvis during locomotion (i.e., walking and running).