{"title":"被动红外运动探测器的探测特性测试","authors":"A. Veľas","doi":"10.35182/tses-2013-0001","DOIUrl":null,"url":null,"abstract":": The article contains a methodology of testing and experimentally acquired particular values of parameters of passive infrared detectors, which are useful in evaluation of the contemporary new technical systems of objects protection and designing of these systems. Detector parameters are indicated in the producer technical documentation and they have to comply with the standards (norms). Their testing is realized by certi fi ed testing laboratories. A testing is realized only on the probationary test sample and the true parameters of the sold detectors may be different from those that are given. This fact is con fi rmed by the results of the measurements, which are given in this article. The measured values are useful as baseline data for the tools for evaluation of measures the physical protection objects.","PeriodicalId":30996,"journal":{"name":"Transactions of the VSB Technical University of Ostrava Safety Engineering Series","volume":"8 1","pages":"35-41"},"PeriodicalIF":0.0000,"publicationDate":"2013-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Testing of Detection Characteristics of the Passive Infrared Motion Detectors\",\"authors\":\"A. Veľas\",\"doi\":\"10.35182/tses-2013-0001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\": The article contains a methodology of testing and experimentally acquired particular values of parameters of passive infrared detectors, which are useful in evaluation of the contemporary new technical systems of objects protection and designing of these systems. Detector parameters are indicated in the producer technical documentation and they have to comply with the standards (norms). Their testing is realized by certi fi ed testing laboratories. A testing is realized only on the probationary test sample and the true parameters of the sold detectors may be different from those that are given. This fact is con fi rmed by the results of the measurements, which are given in this article. The measured values are useful as baseline data for the tools for evaluation of measures the physical protection objects.\",\"PeriodicalId\":30996,\"journal\":{\"name\":\"Transactions of the VSB Technical University of Ostrava Safety Engineering Series\",\"volume\":\"8 1\",\"pages\":\"35-41\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-06-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Transactions of the VSB Technical University of Ostrava Safety Engineering Series\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.35182/tses-2013-0001\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Transactions of the VSB Technical University of Ostrava Safety Engineering Series","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35182/tses-2013-0001","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了一种被动红外探测器的测试方法和实验获得的特定参数值,可用于评价当代新技术系统的目标保护和设计这些系统。探测器参数在生产商技术文件中注明,且必须符合标准(规范)。他们的测试是由认证的测试实验室实现的。只在试用样品上进行测试,所售探测器的真实参数可能与给出的参数不同。本文给出的测量结果证实了这一事实。测量值可作为评估物理保护对象的测量工具的基线数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Testing of Detection Characteristics of the Passive Infrared Motion Detectors
: The article contains a methodology of testing and experimentally acquired particular values of parameters of passive infrared detectors, which are useful in evaluation of the contemporary new technical systems of objects protection and designing of these systems. Detector parameters are indicated in the producer technical documentation and they have to comply with the standards (norms). Their testing is realized by certi fi ed testing laboratories. A testing is realized only on the probationary test sample and the true parameters of the sold detectors may be different from those that are given. This fact is con fi rmed by the results of the measurements, which are given in this article. The measured values are useful as baseline data for the tools for evaluation of measures the physical protection objects.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
3
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信