宫内节育器嵌入导致其破裂:一个案例系列

C. Fernandez, E. Levine, M. Cabiya, I. Ansari, Leah Delfinado
{"title":"宫内节育器嵌入导致其破裂:一个案例系列","authors":"C. Fernandez, E. Levine, M. Cabiya, I. Ansari, Leah Delfinado","doi":"10.33696/gynaecology.2.009","DOIUrl":null,"url":null,"abstract":"As gynecologic providers continue to provide intrauterine devices (IUDs) for long-acting reversable contraception (LARC) with insertion of those devices, the associated complication rate needs to be well-understood, so that patients can make properly informed shared healthcare decisions. There appears to be IUD embedment into the uterine wall that can occur over time, which can cause its fracture when retrieving it with grasp of its string. The authors previously published a case series [1] that described situations in which fractured IUDs were encountered after attempts at their removal occurred. Given that patients continue to be referred to the Director of Gynecologic Sonography at our institution for assistance in managing such complications when they are encountered, this case series was continued, and the authors believe it important to report these findings at this time.","PeriodicalId":93076,"journal":{"name":"Archives of obstetrics and gynaecology","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Intrauterine Device Embedment Resulting in Its Fracture: A Case Series\",\"authors\":\"C. Fernandez, E. Levine, M. Cabiya, I. Ansari, Leah Delfinado\",\"doi\":\"10.33696/gynaecology.2.009\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"As gynecologic providers continue to provide intrauterine devices (IUDs) for long-acting reversable contraception (LARC) with insertion of those devices, the associated complication rate needs to be well-understood, so that patients can make properly informed shared healthcare decisions. There appears to be IUD embedment into the uterine wall that can occur over time, which can cause its fracture when retrieving it with grasp of its string. The authors previously published a case series [1] that described situations in which fractured IUDs were encountered after attempts at their removal occurred. Given that patients continue to be referred to the Director of Gynecologic Sonography at our institution for assistance in managing such complications when they are encountered, this case series was continued, and the authors believe it important to report these findings at this time.\",\"PeriodicalId\":93076,\"journal\":{\"name\":\"Archives of obstetrics and gynaecology\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Archives of obstetrics and gynaecology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.33696/gynaecology.2.009\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of obstetrics and gynaecology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33696/gynaecology.2.009","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

随着妇科医生继续为长效可逆避孕(LARC)提供宫内节育器(iud)并插入这些节育器,需要充分了解相关的并发症发生率,以便患者能够做出适当的知情共享医疗保健决策。随着时间的推移,宫内节育器可能会嵌入子宫壁,这可能会导致宫内节育器在取出时断裂。作者之前发表了一个病例系列[1],描述了在试图取出宫内节育器后遇到断裂的情况。考虑到患者在遇到此类并发症时继续被转介到我院妇科超声检查主任处寻求帮助,本病例系列继续进行,作者认为在此时报告这些发现很重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Intrauterine Device Embedment Resulting in Its Fracture: A Case Series
As gynecologic providers continue to provide intrauterine devices (IUDs) for long-acting reversable contraception (LARC) with insertion of those devices, the associated complication rate needs to be well-understood, so that patients can make properly informed shared healthcare decisions. There appears to be IUD embedment into the uterine wall that can occur over time, which can cause its fracture when retrieving it with grasp of its string. The authors previously published a case series [1] that described situations in which fractured IUDs were encountered after attempts at their removal occurred. Given that patients continue to be referred to the Director of Gynecologic Sonography at our institution for assistance in managing such complications when they are encountered, this case series was continued, and the authors believe it important to report these findings at this time.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信