M. Machida, Ayako Iwata, S. Yamada, S. Otosaka, Takuya Kobayashi, H. Funasaka, T. Morita
{"title":"福岛第一核电站港口排放氚的时间变化估算:日本与世界主要核设施排放氚的时间变化分析与比较","authors":"M. Machida, Ayako Iwata, S. Yamada, S. Otosaka, Takuya Kobayashi, H. Funasaka, T. Morita","doi":"10.3327/taesj.j20.036","DOIUrl":null,"url":null,"abstract":"We estimate the monthly discharge inventory of tritium from the port of Fukushima Daiichi Nuclear Power Plant ( 1F ) from Jun. 2013 to Mar. 2020 using the Voronoi tessellation scheme, following the tritium monitoring inside the port that started in Jun. 2013. As for the missing period from the initial month, Apr. 2011 to May 2013, we calculate the tritium discharge by utilizing the ratio of tritium concentration to 137 Cs concentration in stagnant contaminant water during the initial direct run-off period to Jun. 2011 and the discharge inventory correlation between tritium and 137 Cs for J openly discussed regarding the management of tritium stored inside 1F with the help of the present estimated data and its comparison with the past discharge inventory.","PeriodicalId":55893,"journal":{"name":"Transactions of the Atomic Energy Society of Japan","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Estimation of Temporal Variation of Discharged Tritium from Port of Fukushima Dai-ichi Nuclear Power Plant: Analysis of the Temporal Variation and Comparison with released Tritium from Japan and Major Nuclear Facilities Worldwide\",\"authors\":\"M. Machida, Ayako Iwata, S. Yamada, S. Otosaka, Takuya Kobayashi, H. Funasaka, T. Morita\",\"doi\":\"10.3327/taesj.j20.036\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We estimate the monthly discharge inventory of tritium from the port of Fukushima Daiichi Nuclear Power Plant ( 1F ) from Jun. 2013 to Mar. 2020 using the Voronoi tessellation scheme, following the tritium monitoring inside the port that started in Jun. 2013. As for the missing period from the initial month, Apr. 2011 to May 2013, we calculate the tritium discharge by utilizing the ratio of tritium concentration to 137 Cs concentration in stagnant contaminant water during the initial direct run-off period to Jun. 2011 and the discharge inventory correlation between tritium and 137 Cs for J openly discussed regarding the management of tritium stored inside 1F with the help of the present estimated data and its comparison with the past discharge inventory.\",\"PeriodicalId\":55893,\"journal\":{\"name\":\"Transactions of the Atomic Energy Society of Japan\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Transactions of the Atomic Energy Society of Japan\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3327/taesj.j20.036\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Transactions of the Atomic Energy Society of Japan","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3327/taesj.j20.036","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Engineering","Score":null,"Total":0}
Estimation of Temporal Variation of Discharged Tritium from Port of Fukushima Dai-ichi Nuclear Power Plant: Analysis of the Temporal Variation and Comparison with released Tritium from Japan and Major Nuclear Facilities Worldwide
We estimate the monthly discharge inventory of tritium from the port of Fukushima Daiichi Nuclear Power Plant ( 1F ) from Jun. 2013 to Mar. 2020 using the Voronoi tessellation scheme, following the tritium monitoring inside the port that started in Jun. 2013. As for the missing period from the initial month, Apr. 2011 to May 2013, we calculate the tritium discharge by utilizing the ratio of tritium concentration to 137 Cs concentration in stagnant contaminant water during the initial direct run-off period to Jun. 2011 and the discharge inventory correlation between tritium and 137 Cs for J openly discussed regarding the management of tritium stored inside 1F with the help of the present estimated data and its comparison with the past discharge inventory.