扭矩作用下外固定装置的力学行为分析

IF 0.7 Q3 ENGINEERING, MULTIDISCIPLINARY
N. Pavin, A. Muminović, Elmedin Mešić, Enis Muratović, Muamer Delić
{"title":"扭矩作用下外固定装置的力学行为分析","authors":"N. Pavin, A. Muminović, Elmedin Mešić, Enis Muratović, Muamer Delić","doi":"10.31803/tg-20211201130315","DOIUrl":null,"url":null,"abstract":"In this research, an analysis of the mechanical behaviour for the Orthofix external fixation device under the impact of torque was performed. Research considers application of the Orthofix device on the tibia bone for the case of unstable fracture. 3D (Three Dimensional) model of the Orthofix device was created in the CATIA (Computer Aided Three-Dimensional Interactive Application) software, based on the real device construction. Structural analysis was used to monitor and analyse the stress magnitudes on the specific areas of the fixation device and fracture. With usage of the interfragmentary displacement data for the bone fragments, degrees of stiffness are introduced for the fracture and fixation device. Obtained results are used to specify the mechanical behaviour of the Orthofix fixation device.","PeriodicalId":43419,"journal":{"name":"TEHNICKI GLASNIK-TECHNICAL JOURNAL","volume":null,"pages":null},"PeriodicalIF":0.7000,"publicationDate":"2023-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Analysis of the Mechanical Behaviour for the External Fixation Device under the Impact of Torque\",\"authors\":\"N. Pavin, A. Muminović, Elmedin Mešić, Enis Muratović, Muamer Delić\",\"doi\":\"10.31803/tg-20211201130315\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this research, an analysis of the mechanical behaviour for the Orthofix external fixation device under the impact of torque was performed. Research considers application of the Orthofix device on the tibia bone for the case of unstable fracture. 3D (Three Dimensional) model of the Orthofix device was created in the CATIA (Computer Aided Three-Dimensional Interactive Application) software, based on the real device construction. Structural analysis was used to monitor and analyse the stress magnitudes on the specific areas of the fixation device and fracture. With usage of the interfragmentary displacement data for the bone fragments, degrees of stiffness are introduced for the fracture and fixation device. Obtained results are used to specify the mechanical behaviour of the Orthofix fixation device.\",\"PeriodicalId\":43419,\"journal\":{\"name\":\"TEHNICKI GLASNIK-TECHNICAL JOURNAL\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2023-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"TEHNICKI GLASNIK-TECHNICAL JOURNAL\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31803/tg-20211201130315\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"TEHNICKI GLASNIK-TECHNICAL JOURNAL","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31803/tg-20211201130315","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 3

摘要

在这项研究中,对Orthofix外固定装置在扭矩影响下的力学行为进行了分析。研究了Orthofix装置在胫骨不稳定骨折病例中的应用。在CATIA (Computer Aided Three-Dimensional Interactive Application,计算机辅助三维交互应用)软件中,根据实际装置结构,建立矫形器的三维模型。结构分析用于监测和分析固定装置和骨折特定区域的应力大小。利用骨碎片的碎片间位移数据,引入了骨折和固定装置的刚度。获得的结果用于指定Orthofix固定装置的机械性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Analysis of the Mechanical Behaviour for the External Fixation Device under the Impact of Torque
In this research, an analysis of the mechanical behaviour for the Orthofix external fixation device under the impact of torque was performed. Research considers application of the Orthofix device on the tibia bone for the case of unstable fracture. 3D (Three Dimensional) model of the Orthofix device was created in the CATIA (Computer Aided Three-Dimensional Interactive Application) software, based on the real device construction. Structural analysis was used to monitor and analyse the stress magnitudes on the specific areas of the fixation device and fracture. With usage of the interfragmentary displacement data for the bone fragments, degrees of stiffness are introduced for the fracture and fixation device. Obtained results are used to specify the mechanical behaviour of the Orthofix fixation device.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
TEHNICKI GLASNIK-TECHNICAL JOURNAL
TEHNICKI GLASNIK-TECHNICAL JOURNAL ENGINEERING, MULTIDISCIPLINARY-
CiteScore
1.50
自引率
8.30%
发文量
85
审稿时长
15 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信