三种不同测试:TNO®,Fly Stereo Acuity Test®和StereoTAB®在高等教育学生中的立体视比较研究

Saude Tecnologia Pub Date : 2016-09-20 DOI:10.25758/SET.1341
Ruben Morais, Ana Miguel, Denise Monteiro, Cleide Cassandra, I. Poças
{"title":"三种不同测试:TNO®,Fly Stereo Acuity Test®和StereoTAB®在高等教育学生中的立体视比较研究","authors":"Ruben Morais, Ana Miguel, Denise Monteiro, Cleide Cassandra, I. Poças","doi":"10.25758/SET.1341","DOIUrl":null,"url":null,"abstract":"ABSTRACT: Stereopsis is the perception of depth based on retinal disparity. Global stereopsis depends on the process of random dot stimuli and local stereopsis depends on contour perception. The aim of this study was to correlate three stereopsis tests: TNO ® , StereoTAB ® and Fly Stereo Acuity Test ® and to study the sensitivity and correlation between them, using TNO ® as the gold standard. Other variables as near convergence point, vergences, symptoms and optical correction were correlated with the three tests. Forty-nine students from Escola Superior de Tecnologia da Saude de Lisboa (ESTeSL), aged 18-26 years old were included. The stereopsis mean (standard-deviation-SD) values in each test were: TNO ® = 87.04’’ ±84.09’’; FlyTest ® = 38.18’’ ±34.59’’; StereoTAB ® = 124.89’’ ±137.38’’. About the coefficient of determination: TNO ® and StereoTAB ® with R 2 =0.6e TNO ® and FlyTest ® with R 2 =0.2. Pearson correlation coefficient shows a positive correlation between TNO ® and StereoTAB ® ( r =0.784 with α=0.01). Phi coefficient shows a strong and positive association between TNO ® and StereoTAB ® (Φ=0.848 with α=0.01). In the ROC Curve, the StereoTAB ® has an area under the curve bigger than the FlyTest ® with a sensivity of 92.3% for 94.4% of specificity, so it means that the test is sensitive with a good discriminative power.","PeriodicalId":30555,"journal":{"name":"Saude Tecnologia","volume":"1 1","pages":"12-18"},"PeriodicalIF":0.0000,"publicationDate":"2016-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Estudo comparativo da estereopsia com três testes diferentes: TNO®, Fly Stereo Acuity Test® e StereoTAB® em estudantes do ensino superior\",\"authors\":\"Ruben Morais, Ana Miguel, Denise Monteiro, Cleide Cassandra, I. Poças\",\"doi\":\"10.25758/SET.1341\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ABSTRACT: Stereopsis is the perception of depth based on retinal disparity. Global stereopsis depends on the process of random dot stimuli and local stereopsis depends on contour perception. The aim of this study was to correlate three stereopsis tests: TNO ® , StereoTAB ® and Fly Stereo Acuity Test ® and to study the sensitivity and correlation between them, using TNO ® as the gold standard. Other variables as near convergence point, vergences, symptoms and optical correction were correlated with the three tests. Forty-nine students from Escola Superior de Tecnologia da Saude de Lisboa (ESTeSL), aged 18-26 years old were included. The stereopsis mean (standard-deviation-SD) values in each test were: TNO ® = 87.04’’ ±84.09’’; FlyTest ® = 38.18’’ ±34.59’’; StereoTAB ® = 124.89’’ ±137.38’’. About the coefficient of determination: TNO ® and StereoTAB ® with R 2 =0.6e TNO ® and FlyTest ® with R 2 =0.2. Pearson correlation coefficient shows a positive correlation between TNO ® and StereoTAB ® ( r =0.784 with α=0.01). Phi coefficient shows a strong and positive association between TNO ® and StereoTAB ® (Φ=0.848 with α=0.01). In the ROC Curve, the StereoTAB ® has an area under the curve bigger than the FlyTest ® with a sensivity of 92.3% for 94.4% of specificity, so it means that the test is sensitive with a good discriminative power.\",\"PeriodicalId\":30555,\"journal\":{\"name\":\"Saude Tecnologia\",\"volume\":\"1 1\",\"pages\":\"12-18\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-09-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Saude Tecnologia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.25758/SET.1341\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Saude Tecnologia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25758/SET.1341","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

立体视觉是基于视网膜视差的深度感知。全局立体视依赖于随机点刺激过程,局部立体视依赖于轮廓感知。本研究的目的是将三种立体视觉测试:TNO®、StereoTAB®和Fly Stereo Acuity Test®相关联,并以TNO®为金标准,研究它们之间的灵敏度和相关性。其他变量如近会聚点、会聚、症状和光学校正与三个测试相关。49名来自里斯本高等理工学院(ESTeSL)的学生,年龄18-26岁。各试验立体视觉均值(标准差- sd)值为:TNO®= 87.04±84.09;FlyTest®= 38.18 "±34.59 ";StereoTAB®= 124.89 "±137.38 "。关于决定系数:TNO®和StereoTAB®r2 =0.6; TNO®和FlyTest®r2 =0.2。Pearson相关系数显示TNO®与StereoTAB®呈正相关(r =0.784, α=0.01)。Phi系数显示TNO®与StereoTAB®呈正相关(Φ=0.848, α=0.01)。在ROC曲线上,StereoTAB®的曲线下面积大于FlyTest®,灵敏度为92.3%,特异度为94.4%,说明该试验灵敏度高,具有良好的判别能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Estudo comparativo da estereopsia com três testes diferentes: TNO®, Fly Stereo Acuity Test® e StereoTAB® em estudantes do ensino superior
ABSTRACT: Stereopsis is the perception of depth based on retinal disparity. Global stereopsis depends on the process of random dot stimuli and local stereopsis depends on contour perception. The aim of this study was to correlate three stereopsis tests: TNO ® , StereoTAB ® and Fly Stereo Acuity Test ® and to study the sensitivity and correlation between them, using TNO ® as the gold standard. Other variables as near convergence point, vergences, symptoms and optical correction were correlated with the three tests. Forty-nine students from Escola Superior de Tecnologia da Saude de Lisboa (ESTeSL), aged 18-26 years old were included. The stereopsis mean (standard-deviation-SD) values in each test were: TNO ® = 87.04’’ ±84.09’’; FlyTest ® = 38.18’’ ±34.59’’; StereoTAB ® = 124.89’’ ±137.38’’. About the coefficient of determination: TNO ® and StereoTAB ® with R 2 =0.6e TNO ® and FlyTest ® with R 2 =0.2. Pearson correlation coefficient shows a positive correlation between TNO ® and StereoTAB ® ( r =0.784 with α=0.01). Phi coefficient shows a strong and positive association between TNO ® and StereoTAB ® (Φ=0.848 with α=0.01). In the ROC Curve, the StereoTAB ® has an area under the curve bigger than the FlyTest ® with a sensivity of 92.3% for 94.4% of specificity, so it means that the test is sensitive with a good discriminative power.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
16
审稿时长
26 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信