通过调节通风来优化教学室的二氧化碳浓度

Q4 Environmental Science
E. Słodczyk, D. Suszanowicz
{"title":"通过调节通风来优化教学室的二氧化碳浓度","authors":"E. Słodczyk, D. Suszanowicz","doi":"10.2428/ECEA.2016.23(3)27","DOIUrl":null,"url":null,"abstract":"Poor ventilation of didactic rooms can interfere with students’ ability to concentrate and even cause them to suffer headaches. This is a significant issue as the ventilation systems of most lecture buildings in Poland do not provide proper air exchange. This paper presents findings of research on air parameters research in the didactic rooms of various sizes. Rooms for classes should ensure climatic comfort i.e. proper humidity and air temperature, physical and biological air quality, and low concentration of carbon dioxide. The research suggested that natural ventilation should not be used, and further research was done after the upgrading of ventilation systems and installation of exhaust fans. The coefficients of carbon dioxide emissions by one student depend on the number of people and size of the room were calculated. Designated coefficients will be used in the algorithm for determining the parameters of the fans in the ventilation system of the classrooms and lecture halls.","PeriodicalId":44472,"journal":{"name":"ECOLOGICAL CHEMISTRY AND ENGINEERING A-CHEMIA I INZYNIERIA EKOLOGICZNA A","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2016-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Optimization of carbon dioxide concentration in the didactic rooms by the regulation of ventilation\",\"authors\":\"E. Słodczyk, D. Suszanowicz\",\"doi\":\"10.2428/ECEA.2016.23(3)27\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Poor ventilation of didactic rooms can interfere with students’ ability to concentrate and even cause them to suffer headaches. This is a significant issue as the ventilation systems of most lecture buildings in Poland do not provide proper air exchange. This paper presents findings of research on air parameters research in the didactic rooms of various sizes. Rooms for classes should ensure climatic comfort i.e. proper humidity and air temperature, physical and biological air quality, and low concentration of carbon dioxide. The research suggested that natural ventilation should not be used, and further research was done after the upgrading of ventilation systems and installation of exhaust fans. The coefficients of carbon dioxide emissions by one student depend on the number of people and size of the room were calculated. Designated coefficients will be used in the algorithm for determining the parameters of the fans in the ventilation system of the classrooms and lecture halls.\",\"PeriodicalId\":44472,\"journal\":{\"name\":\"ECOLOGICAL CHEMISTRY AND ENGINEERING A-CHEMIA I INZYNIERIA EKOLOGICZNA A\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ECOLOGICAL CHEMISTRY AND ENGINEERING A-CHEMIA I INZYNIERIA EKOLOGICZNA A\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2428/ECEA.2016.23(3)27\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Environmental Science\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ECOLOGICAL CHEMISTRY AND ENGINEERING A-CHEMIA I INZYNIERIA EKOLOGICZNA A","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2428/ECEA.2016.23(3)27","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Environmental Science","Score":null,"Total":0}
引用次数: 6

摘要

教学教室通风不良会影响学生集中注意力,甚至导致他们头痛。这是一个重要的问题,因为波兰大多数教学楼的通风系统不能提供适当的空气交换。本文介绍了不同规模教学教室空气参数研究的研究结果。教室应确保气候舒适,即适当的湿度和空气温度,物理和生物空气质量,以及低浓度的二氧化碳。研究建议不宜采用自然通风,待通风系统升级、安装排风机后再作进一步研究。每个学生的二氧化碳排放系数取决于人数和房间的大小。算法将使用指定的系数来确定教室和报告厅通风系统中风扇的参数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Optimization of carbon dioxide concentration in the didactic rooms by the regulation of ventilation
Poor ventilation of didactic rooms can interfere with students’ ability to concentrate and even cause them to suffer headaches. This is a significant issue as the ventilation systems of most lecture buildings in Poland do not provide proper air exchange. This paper presents findings of research on air parameters research in the didactic rooms of various sizes. Rooms for classes should ensure climatic comfort i.e. proper humidity and air temperature, physical and biological air quality, and low concentration of carbon dioxide. The research suggested that natural ventilation should not be used, and further research was done after the upgrading of ventilation systems and installation of exhaust fans. The coefficients of carbon dioxide emissions by one student depend on the number of people and size of the room were calculated. Designated coefficients will be used in the algorithm for determining the parameters of the fans in the ventilation system of the classrooms and lecture halls.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信