{"title":"变电网条件下的实时谐波识别","authors":"A. E. Bulycheva, A. S. Yanchenko","doi":"10.2298/SJEE2101029B","DOIUrl":null,"url":null,"abstract":"One of the challenges of the power quality management is a need for reliable harmonic identification in grids with multiple non-linear loads. This paper proposes a novel method to accurately determine time-varying harmonic contributions of non-linear loads to the total grid voltage distortion. The use of the invasive measurement approach and ternary pulse sequence as a stimuli guarantees an accurate assessment of harmonic contribution with the account for timevariating harmonic impacts. The application of proposed approach is demonstrated by means of time-domain grid simulation with implemented white-box model of a pulse sequence generator. Statistical estimation of the accuracy of the proposed approach as well as comparison with typical harmonic identification methods justify its effectiveness under non-stationary network conditions.","PeriodicalId":37704,"journal":{"name":"Serbian Journal of Electrical Engineering","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Real-time harmonic identification under varying grid conditions\",\"authors\":\"A. E. Bulycheva, A. S. Yanchenko\",\"doi\":\"10.2298/SJEE2101029B\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"One of the challenges of the power quality management is a need for reliable harmonic identification in grids with multiple non-linear loads. This paper proposes a novel method to accurately determine time-varying harmonic contributions of non-linear loads to the total grid voltage distortion. The use of the invasive measurement approach and ternary pulse sequence as a stimuli guarantees an accurate assessment of harmonic contribution with the account for timevariating harmonic impacts. The application of proposed approach is demonstrated by means of time-domain grid simulation with implemented white-box model of a pulse sequence generator. Statistical estimation of the accuracy of the proposed approach as well as comparison with typical harmonic identification methods justify its effectiveness under non-stationary network conditions.\",\"PeriodicalId\":37704,\"journal\":{\"name\":\"Serbian Journal of Electrical Engineering\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Serbian Journal of Electrical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2298/SJEE2101029B\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Serbian Journal of Electrical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2298/SJEE2101029B","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
Real-time harmonic identification under varying grid conditions
One of the challenges of the power quality management is a need for reliable harmonic identification in grids with multiple non-linear loads. This paper proposes a novel method to accurately determine time-varying harmonic contributions of non-linear loads to the total grid voltage distortion. The use of the invasive measurement approach and ternary pulse sequence as a stimuli guarantees an accurate assessment of harmonic contribution with the account for timevariating harmonic impacts. The application of proposed approach is demonstrated by means of time-domain grid simulation with implemented white-box model of a pulse sequence generator. Statistical estimation of the accuracy of the proposed approach as well as comparison with typical harmonic identification methods justify its effectiveness under non-stationary network conditions.
期刊介绍:
The main aims of the Journal are to publish peer review papers giving results of the fundamental and applied research in the field of electrical engineering. The Journal covers a wide scope of problems in the following scientific fields: Applied and Theoretical Electromagnetics, Instrumentation and Measurement, Power Engineering, Power Systems, Electrical Machines, Electrical Drives, Electronics, Telecommunications, Computer Engineering, Automatic Control and Systems, Mechatronics, Electrical Materials, Information Technologies, Engineering Mathematics, etc.