Benazza Baghdadi, B. Abdelber, Reineix Alain, Dafif Omar, Slimani Helima
{"title":"高频屏蔽或非双绞线电缆串扰特性的实验研究","authors":"Benazza Baghdadi, B. Abdelber, Reineix Alain, Dafif Omar, Slimani Helima","doi":"10.2298/sjee1903311b","DOIUrl":null,"url":null,"abstract":"Electromagnetic disturbances from natural phenomena such as lightning, or those generated from industrial activity, can cause harmful interference in onboard electronic systems. The disturbances are generally transformed into radiated and conducted disturbances, using wired connections to spread their effects in electrical and electronic systems. In order to identify the paths of propagation and coupling of these HF currents into a complete system and propose solutions to reduce EMC interference, it is necessary and important to carry out experimental case studies on the coupling between shielded as well as unarmoured cables, in order to identify the importance of differential and common-mode currents. Measurements were made using a 4-way vector network analyser giving the results of the crosstalk between victim and culprit cables as well as for module and phase.","PeriodicalId":37704,"journal":{"name":"Serbian Journal of Electrical Engineering","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"Experimental study of the behaviour of the crosstalk of shielded or untwisted-pair cables in high frequency\",\"authors\":\"Benazza Baghdadi, B. Abdelber, Reineix Alain, Dafif Omar, Slimani Helima\",\"doi\":\"10.2298/sjee1903311b\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Electromagnetic disturbances from natural phenomena such as lightning, or those generated from industrial activity, can cause harmful interference in onboard electronic systems. The disturbances are generally transformed into radiated and conducted disturbances, using wired connections to spread their effects in electrical and electronic systems. In order to identify the paths of propagation and coupling of these HF currents into a complete system and propose solutions to reduce EMC interference, it is necessary and important to carry out experimental case studies on the coupling between shielded as well as unarmoured cables, in order to identify the importance of differential and common-mode currents. Measurements were made using a 4-way vector network analyser giving the results of the crosstalk between victim and culprit cables as well as for module and phase.\",\"PeriodicalId\":37704,\"journal\":{\"name\":\"Serbian Journal of Electrical Engineering\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Serbian Journal of Electrical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2298/sjee1903311b\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Serbian Journal of Electrical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2298/sjee1903311b","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
Experimental study of the behaviour of the crosstalk of shielded or untwisted-pair cables in high frequency
Electromagnetic disturbances from natural phenomena such as lightning, or those generated from industrial activity, can cause harmful interference in onboard electronic systems. The disturbances are generally transformed into radiated and conducted disturbances, using wired connections to spread their effects in electrical and electronic systems. In order to identify the paths of propagation and coupling of these HF currents into a complete system and propose solutions to reduce EMC interference, it is necessary and important to carry out experimental case studies on the coupling between shielded as well as unarmoured cables, in order to identify the importance of differential and common-mode currents. Measurements were made using a 4-way vector network analyser giving the results of the crosstalk between victim and culprit cables as well as for module and phase.
期刊介绍:
The main aims of the Journal are to publish peer review papers giving results of the fundamental and applied research in the field of electrical engineering. The Journal covers a wide scope of problems in the following scientific fields: Applied and Theoretical Electromagnetics, Instrumentation and Measurement, Power Engineering, Power Systems, Electrical Machines, Electrical Drives, Electronics, Telecommunications, Computer Engineering, Automatic Control and Systems, Mechatronics, Electrical Materials, Information Technologies, Engineering Mathematics, etc.