以镧为化学改性剂的一次性移液管萃取法在高分辨连续源石墨炉原子吸收光谱法测定镱中的应用

IF 1.3 4区 化学 Q3 CHEMISTRY, MULTIDISCIPLINARY
Diogo M. Betiolo, Heloisa R. Cadorim, E. Carasek, Tatiane Maranhão
{"title":"以镧为化学改性剂的一次性移液管萃取法在高分辨连续源石墨炉原子吸收光谱法测定镱中的应用","authors":"Diogo M. Betiolo, Heloisa R. Cadorim, E. Carasek, Tatiane Maranhão","doi":"10.21577/0103-5053.20230021","DOIUrl":null,"url":null,"abstract":"The use of extraction technique with disposable tips (DPX) was applied for the first time for the extraction and preconcentration of Yb in samples of liquid waste from the petrochemical industry and environmental water using bioabsorbent cork. The use of cork as an extracting phase in the determination of Yb by high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GF AAS) was evaluated. The pyrolysis and atomization temperatures were optimized at 1400 and 2400 ºC, respectively. H2SO4, HNO3 and HCl acids were compared in the steps of cleaning the extraction phase and desorption of the analyte by DPX. The best extraction in the selected conditions was obtained with pH 8.0 and 5% v/v HCl. The recoveries were close to 100% for residual water and drinking water, 33 to 77% for produced water and 64 to 93% for river water. Tests with interfering ions in different concentrations were performed. The relative limit of quantification (LOQ) and limit of detection (LOD) were estimated at 0.03 and 0.01 µg L-1, respectively. The total time for the preparation of the samples by DPX was close to 1 min per sample. Extraction and pre-concentration were observed using DPX with a preenrichment factor of approximately 4 times.","PeriodicalId":17257,"journal":{"name":"Journal of the Brazilian Chemical Society","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2023-07-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Application of Disposable Pipette Extraction for Determination of Yb by High‑Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry Using Lanthanum as a Chemical Modifier\",\"authors\":\"Diogo M. Betiolo, Heloisa R. Cadorim, E. Carasek, Tatiane Maranhão\",\"doi\":\"10.21577/0103-5053.20230021\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The use of extraction technique with disposable tips (DPX) was applied for the first time for the extraction and preconcentration of Yb in samples of liquid waste from the petrochemical industry and environmental water using bioabsorbent cork. The use of cork as an extracting phase in the determination of Yb by high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GF AAS) was evaluated. The pyrolysis and atomization temperatures were optimized at 1400 and 2400 ºC, respectively. H2SO4, HNO3 and HCl acids were compared in the steps of cleaning the extraction phase and desorption of the analyte by DPX. The best extraction in the selected conditions was obtained with pH 8.0 and 5% v/v HCl. The recoveries were close to 100% for residual water and drinking water, 33 to 77% for produced water and 64 to 93% for river water. Tests with interfering ions in different concentrations were performed. The relative limit of quantification (LOQ) and limit of detection (LOD) were estimated at 0.03 and 0.01 µg L-1, respectively. The total time for the preparation of the samples by DPX was close to 1 min per sample. Extraction and pre-concentration were observed using DPX with a preenrichment factor of approximately 4 times.\",\"PeriodicalId\":17257,\"journal\":{\"name\":\"Journal of the Brazilian Chemical Society\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2023-07-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Brazilian Chemical Society\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.21577/0103-5053.20230021\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Brazilian Chemical Society","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.21577/0103-5053.20230021","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

首次将一次性尖端提取技术(DPX)应用于生物吸附软木对石油化工废液和环境用水样品中Yb的提取和富集。研究了高分辨率连续源石墨炉原子吸收光谱法(HR-CS GF AAS)中以软木为萃取相测定Yb的方法。优化的热解温度为1400℃,雾化温度为2400℃。比较了H2SO4、HNO3和HCl酸对分析物萃取相的清洗和DPX解吸的影响。在所选条件下,pH为8.0,HCl为5%,提取效果最佳。剩余水和饮用水的回收率接近100%,采出水的回收率为33 ~ 77%,河水的回收率为64 ~ 93%。用不同浓度的干扰离子进行了试验。相对定量限(LOQ)和检出限(LOD)分别为0.03和0.01µg L-1。DPX制备样品的总时间接近1 min /个样品。用预富集因子约为4倍的DPX进行提取和预富集。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Application of Disposable Pipette Extraction for Determination of Yb by High‑Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry Using Lanthanum as a Chemical Modifier
The use of extraction technique with disposable tips (DPX) was applied for the first time for the extraction and preconcentration of Yb in samples of liquid waste from the petrochemical industry and environmental water using bioabsorbent cork. The use of cork as an extracting phase in the determination of Yb by high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GF AAS) was evaluated. The pyrolysis and atomization temperatures were optimized at 1400 and 2400 ºC, respectively. H2SO4, HNO3 and HCl acids were compared in the steps of cleaning the extraction phase and desorption of the analyte by DPX. The best extraction in the selected conditions was obtained with pH 8.0 and 5% v/v HCl. The recoveries were close to 100% for residual water and drinking water, 33 to 77% for produced water and 64 to 93% for river water. Tests with interfering ions in different concentrations were performed. The relative limit of quantification (LOQ) and limit of detection (LOD) were estimated at 0.03 and 0.01 µg L-1, respectively. The total time for the preparation of the samples by DPX was close to 1 min per sample. Extraction and pre-concentration were observed using DPX with a preenrichment factor of approximately 4 times.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.90
自引率
7.10%
发文量
99
审稿时长
3.4 months
期刊介绍: The Journal of the Brazilian Chemical Society embraces all aspects of chemistry except education, philosophy and history of chemistry. It is a medium for reporting selected original and significant contributions to new chemical knowledge.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信