{"title":"PMU测量误差的统计行为:实验表征","authors":"Paolo Castello;Carlo Muscas;Paolo Attilio Pegoraro","doi":"10.1109/OJIM.2022.3205678","DOIUrl":null,"url":null,"abstract":"Different power system applications based on synchrophasors measured in different nodes of the electric grid require information about the statistical distribution of the errors introduced by the phasor measurement units (PMUs). The performance of these applications can be significantly affected by possible incorrect assumptions. The Gaussian distribution has been historically assumed in most of the approaches, but some more recent studies suggest the possibility of considering different distributions for more accurate modeling of the actual situation. In this article, proper statistical tools applied to the results achieved through a high-performance experimental test system are proposed to assess the statistical distribution of PMU errors under controlled steady-state conditions, thus providing a basis for defining suitable models to be used in specific applications.","PeriodicalId":100630,"journal":{"name":"IEEE Open Journal of Instrumentation and Measurement","volume":"1 ","pages":"1-9"},"PeriodicalIF":0.0000,"publicationDate":"2022-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/iel7/9552935/9687502/09887624.pdf","citationCount":"6","resultStr":"{\"title\":\"Statistical Behavior of PMU Measurement Errors: An Experimental Characterization\",\"authors\":\"Paolo Castello;Carlo Muscas;Paolo Attilio Pegoraro\",\"doi\":\"10.1109/OJIM.2022.3205678\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Different power system applications based on synchrophasors measured in different nodes of the electric grid require information about the statistical distribution of the errors introduced by the phasor measurement units (PMUs). The performance of these applications can be significantly affected by possible incorrect assumptions. The Gaussian distribution has been historically assumed in most of the approaches, but some more recent studies suggest the possibility of considering different distributions for more accurate modeling of the actual situation. In this article, proper statistical tools applied to the results achieved through a high-performance experimental test system are proposed to assess the statistical distribution of PMU errors under controlled steady-state conditions, thus providing a basis for defining suitable models to be used in specific applications.\",\"PeriodicalId\":100630,\"journal\":{\"name\":\"IEEE Open Journal of Instrumentation and Measurement\",\"volume\":\"1 \",\"pages\":\"1-9\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-09-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ieeexplore.ieee.org/iel7/9552935/9687502/09887624.pdf\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Open Journal of Instrumentation and Measurement\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/9887624/\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Open Journal of Instrumentation and Measurement","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/9887624/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

基于在电网的不同节点中测量的同步相量的不同电力系统应用需要关于相量测量单元(PMU)引入的误差的统计分布的信息。这些应用程序的性能可能会受到可能的错误假设的严重影响。历史上,大多数方法都假设高斯分布,但最近的一些研究表明,为了更准确地模拟实际情况,可以考虑不同的分布。在本文中,提出了将适当的统计工具应用于通过高性能实验测试系统获得的结果,以评估受控稳态条件下PMU误差的统计分布,从而为定义在特定应用中使用的合适模型提供了基础。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Statistical Behavior of PMU Measurement Errors: An Experimental Characterization
Different power system applications based on synchrophasors measured in different nodes of the electric grid require information about the statistical distribution of the errors introduced by the phasor measurement units (PMUs). The performance of these applications can be significantly affected by possible incorrect assumptions. The Gaussian distribution has been historically assumed in most of the approaches, but some more recent studies suggest the possibility of considering different distributions for more accurate modeling of the actual situation. In this article, proper statistical tools applied to the results achieved through a high-performance experimental test system are proposed to assess the statistical distribution of PMU errors under controlled steady-state conditions, thus providing a basis for defining suitable models to be used in specific applications.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信