{"title":"H线圈在深部经颅磁刺激中的安全性评价","authors":"Mai Lu;Shoogo Ueno","doi":"10.1109/LMAG.2022.3198370","DOIUrl":null,"url":null,"abstract":"This work investigates the exposure experienced by the nursing staff executing deep transcranial magnetic stimulations (TMS) using H-coil. The safety assessment was implemented by employing the H-coil and realistic human model. The 144 relative positions of the H-coil with respect to the TMS operator body were considered, including the distance and vertical height. Dependence of the magnetic flux density and induced electric fields in the human model were obtained by using the impedance method. Results were compared with the International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines. Regarding the occupational exposure, safe distances of 120 and 100 cm are derived from the ICNIRP reference level (RL) and basic restriction (BR), respectively. At the distance of 100 cm, the exposure level does not exceed the ICNIRP BR, and although the exposure level exceeds the RL, continued exposure is allowed. The findings suggest that nursing staff should stand at least 100 cm apart from the H-coil.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2022-08-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/iel7/5165412/9656771/09857568.pdf","citationCount":"1","resultStr":"{\"title\":\"Safety Assessment of H-Coil for Nursing Staff in Deep Transcranial Magnetic Stimulation\",\"authors\":\"Mai Lu;Shoogo Ueno\",\"doi\":\"10.1109/LMAG.2022.3198370\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This work investigates the exposure experienced by the nursing staff executing deep transcranial magnetic stimulations (TMS) using H-coil. The safety assessment was implemented by employing the H-coil and realistic human model. The 144 relative positions of the H-coil with respect to the TMS operator body were considered, including the distance and vertical height. Dependence of the magnetic flux density and induced electric fields in the human model were obtained by using the impedance method. Results were compared with the International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines. Regarding the occupational exposure, safe distances of 120 and 100 cm are derived from the ICNIRP reference level (RL) and basic restriction (BR), respectively. At the distance of 100 cm, the exposure level does not exceed the ICNIRP BR, and although the exposure level exceeds the RL, continued exposure is allowed. The findings suggest that nursing staff should stand at least 100 cm apart from the H-coil.\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2022-08-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ieeexplore.ieee.org/iel7/5165412/9656771/09857568.pdf\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/9857568/\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"101","ListUrlMain":"https://ieeexplore.ieee.org/document/9857568/","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Safety Assessment of H-Coil for Nursing Staff in Deep Transcranial Magnetic Stimulation
This work investigates the exposure experienced by the nursing staff executing deep transcranial magnetic stimulations (TMS) using H-coil. The safety assessment was implemented by employing the H-coil and realistic human model. The 144 relative positions of the H-coil with respect to the TMS operator body were considered, including the distance and vertical height. Dependence of the magnetic flux density and induced electric fields in the human model were obtained by using the impedance method. Results were compared with the International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines. Regarding the occupational exposure, safe distances of 120 and 100 cm are derived from the ICNIRP reference level (RL) and basic restriction (BR), respectively. At the distance of 100 cm, the exposure level does not exceed the ICNIRP BR, and although the exposure level exceeds the RL, continued exposure is allowed. The findings suggest that nursing staff should stand at least 100 cm apart from the H-coil.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.