乳牙微渗漏的修复材料和酸的作用

S. K. Bussadori, A. Muench
{"title":"乳牙微渗漏的修复材料和酸的作用","authors":"S. K. Bussadori, A. Muench","doi":"10.1590/S0103-06631999000400009","DOIUrl":null,"url":null,"abstract":"The purpose of this research was to evaluate microleakage on proximal restorations of primary teeth, using four materials (Dyract, Vitremer, Z100 and Fuji II LC). Acid etching was performed in only one group. Proximal cavities were prepared with the following measures (mm): height, 4; width, 3; depth, 2. Restoring was performed according to manufacturer’s instructions, and specimens were stored in distilled water for seven days, at 37oC. Afterwards, thermal cycling was performed (700 cycles at 5 and 55oC, for one minute in each temperature). Specimens were then immersed in 0.5% methylene blue solution, and prepared for evaluation. The results led to the following conclusions: there were great differences of scores between materials, 0.1 (Dyract) and 4.0 (Fuji II LC); Vitremer and Z100 presented similar values (respectively, in scores, 1.7 and 1.6); Fuji II LC presented the largest microleakage, which decreased with the acid etching.","PeriodicalId":77611,"journal":{"name":"Revista de odontologia da Universidade de Sao Paulo","volume":"13 1","pages":"369-373"},"PeriodicalIF":0.0000,"publicationDate":"1999-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Microinfiltração em dentes decíduos em função de materiais restauradores e condicionamento ácido\",\"authors\":\"S. K. Bussadori, A. Muench\",\"doi\":\"10.1590/S0103-06631999000400009\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The purpose of this research was to evaluate microleakage on proximal restorations of primary teeth, using four materials (Dyract, Vitremer, Z100 and Fuji II LC). Acid etching was performed in only one group. Proximal cavities were prepared with the following measures (mm): height, 4; width, 3; depth, 2. Restoring was performed according to manufacturer’s instructions, and specimens were stored in distilled water for seven days, at 37oC. Afterwards, thermal cycling was performed (700 cycles at 5 and 55oC, for one minute in each temperature). Specimens were then immersed in 0.5% methylene blue solution, and prepared for evaluation. The results led to the following conclusions: there were great differences of scores between materials, 0.1 (Dyract) and 4.0 (Fuji II LC); Vitremer and Z100 presented similar values (respectively, in scores, 1.7 and 1.6); Fuji II LC presented the largest microleakage, which decreased with the acid etching.\",\"PeriodicalId\":77611,\"journal\":{\"name\":\"Revista de odontologia da Universidade de Sao Paulo\",\"volume\":\"13 1\",\"pages\":\"369-373\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revista de odontologia da Universidade de Sao Paulo\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1590/S0103-06631999000400009\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista de odontologia da Universidade de Sao Paulo","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/S0103-06631999000400009","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本研究采用四种材料(Dyract、Vitremer、Z100和Fuji II LC)对乳牙近端修复体的微渗漏进行评价。仅一组进行酸蚀。近端空腔采用以下测量(mm):高度,4;宽度,3;深度,2。按照制造商的说明进行修复,标本在37℃的蒸馏水中保存7天。然后进行热循环(在5℃和55℃下循环700次,每种温度各1分钟)。然后将标本浸入0.5%亚甲基蓝溶液中,准备评估。结果表明:材料间的评分差异较大,分别为0.1 (Dyract)和4.0 (Fuji II LC);Vitremer和Z100的得分相近(分别为1.7分和1.6分);富士II型LC微漏最大,随酸蚀而减小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Microinfiltração em dentes decíduos em função de materiais restauradores e condicionamento ácido
The purpose of this research was to evaluate microleakage on proximal restorations of primary teeth, using four materials (Dyract, Vitremer, Z100 and Fuji II LC). Acid etching was performed in only one group. Proximal cavities were prepared with the following measures (mm): height, 4; width, 3; depth, 2. Restoring was performed according to manufacturer’s instructions, and specimens were stored in distilled water for seven days, at 37oC. Afterwards, thermal cycling was performed (700 cycles at 5 and 55oC, for one minute in each temperature). Specimens were then immersed in 0.5% methylene blue solution, and prepared for evaluation. The results led to the following conclusions: there were great differences of scores between materials, 0.1 (Dyract) and 4.0 (Fuji II LC); Vitremer and Z100 presented similar values (respectively, in scores, 1.7 and 1.6); Fuji II LC presented the largest microleakage, which decreased with the acid etching.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信