使用旋转器械后模拟通道曲率的变化

Suely Maria Santos Lamarão, Marcelo Bidóia dos Santos, João Humberto Antoniazzi
{"title":"使用旋转器械后模拟通道曲率的变化","authors":"Suely Maria Santos Lamarão, Marcelo Bidóia dos Santos, João Humberto Antoniazzi","doi":"10.1590/S0103-06631999000100017","DOIUrl":null,"url":null,"abstract":"After instrumentation, the root canal acquires the necessary shape for a perfect adaptation of filling material. During this phase cutting end and LX type an interaction between instrument and root canal is necessary in order to reduce alterations that could occur at this point. This study evaluated the action of two mechanical-rotatory endodontic instruments, Quantec files 2000 serie type SC with blunt end, during the instrumentation of simulated canals curved between 20 and 35 degrees, using quantec graduating tapers. Results showed that the mean curvature alteration of group I canals that were instrumented with SC files, was 2,15%, and for group II instrumented with LX files, was 2,61%. Furthermore group I canals showed lower percentage of curvature alteration. Mann-Whitney tests showed no significant statistical difference at 5% between experimental groups.","PeriodicalId":77611,"journal":{"name":"Revista de odontologia da Universidade de Sao Paulo","volume":"13 1","pages":"89-92"},"PeriodicalIF":0.0000,"publicationDate":"1999-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Modificações da curvatura de canais simulados após emprego de instrumentos rotatórios\",\"authors\":\"Suely Maria Santos Lamarão, Marcelo Bidóia dos Santos, João Humberto Antoniazzi\",\"doi\":\"10.1590/S0103-06631999000100017\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"After instrumentation, the root canal acquires the necessary shape for a perfect adaptation of filling material. During this phase cutting end and LX type an interaction between instrument and root canal is necessary in order to reduce alterations that could occur at this point. This study evaluated the action of two mechanical-rotatory endodontic instruments, Quantec files 2000 serie type SC with blunt end, during the instrumentation of simulated canals curved between 20 and 35 degrees, using quantec graduating tapers. Results showed that the mean curvature alteration of group I canals that were instrumented with SC files, was 2,15%, and for group II instrumented with LX files, was 2,61%. Furthermore group I canals showed lower percentage of curvature alteration. Mann-Whitney tests showed no significant statistical difference at 5% between experimental groups.\",\"PeriodicalId\":77611,\"journal\":{\"name\":\"Revista de odontologia da Universidade de Sao Paulo\",\"volume\":\"13 1\",\"pages\":\"89-92\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revista de odontologia da Universidade de Sao Paulo\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1590/S0103-06631999000100017\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista de odontologia da Universidade de Sao Paulo","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/S0103-06631999000100017","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

预备后,根管获得所需的形状,以完美地适应充填材料。在这一阶段,为了减少此时可能发生的改变,器械和根管之间的相互作用是必要的。本研究评估了两种机械旋转根管器械,Quantec锉2000系列SC钝端,在模拟根管弯曲20 ~ 35度的过程中,使用Quantec渐变锥的作用。结果显示,SC锉组I组的平均曲率改变为2.15%,LX锉组II组的平均曲率改变为2.61%。此外,I组的管道曲率改变率较低。Mann-Whitney检验显示实验组间差异无统计学意义(5%)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Modificações da curvatura de canais simulados após emprego de instrumentos rotatórios
After instrumentation, the root canal acquires the necessary shape for a perfect adaptation of filling material. During this phase cutting end and LX type an interaction between instrument and root canal is necessary in order to reduce alterations that could occur at this point. This study evaluated the action of two mechanical-rotatory endodontic instruments, Quantec files 2000 serie type SC with blunt end, during the instrumentation of simulated canals curved between 20 and 35 degrees, using quantec graduating tapers. Results showed that the mean curvature alteration of group I canals that were instrumented with SC files, was 2,15%, and for group II instrumented with LX files, was 2,61%. Furthermore group I canals showed lower percentage of curvature alteration. Mann-Whitney tests showed no significant statistical difference at 5% between experimental groups.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信