{"title":"冠状动脉窦内支架植入术稳定左心室四极导联","authors":"P. Barwad, K. S. Vemuri, C. Pruthvi, Jyothi Vijay","doi":"10.15761/JCCR.1000137","DOIUrl":null,"url":null,"abstract":"The position and stability of left ventricular (LV) lead is important in determining the success of Cardiac Resynchronization Therapy (CRT). Lead dislodgement is a common problem accounting for up to 2 to 12% of cases. We report a case of successful implantation of LV lead by jailing the lead with stent implantation in the coronary sinus. *Correspondence to: Parag Barwad, Department of Cardiology, Advanced Cardiac Centre, Post Graduate Institute of Medical Education & Research, Chandigarh-160012, India, Tel: +91 8968732470, E-mail: paragaims@gmail.com","PeriodicalId":73637,"journal":{"name":"Journal of cardiology case reports","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Coronary sinus stenting for stabilizing a difficult quadripolar left ventricular lead\",\"authors\":\"P. Barwad, K. S. Vemuri, C. Pruthvi, Jyothi Vijay\",\"doi\":\"10.15761/JCCR.1000137\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The position and stability of left ventricular (LV) lead is important in determining the success of Cardiac Resynchronization Therapy (CRT). Lead dislodgement is a common problem accounting for up to 2 to 12% of cases. We report a case of successful implantation of LV lead by jailing the lead with stent implantation in the coronary sinus. *Correspondence to: Parag Barwad, Department of Cardiology, Advanced Cardiac Centre, Post Graduate Institute of Medical Education & Research, Chandigarh-160012, India, Tel: +91 8968732470, E-mail: paragaims@gmail.com\",\"PeriodicalId\":73637,\"journal\":{\"name\":\"Journal of cardiology case reports\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of cardiology case reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15761/JCCR.1000137\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of cardiology case reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15761/JCCR.1000137","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Coronary sinus stenting for stabilizing a difficult quadripolar left ventricular lead
The position and stability of left ventricular (LV) lead is important in determining the success of Cardiac Resynchronization Therapy (CRT). Lead dislodgement is a common problem accounting for up to 2 to 12% of cases. We report a case of successful implantation of LV lead by jailing the lead with stent implantation in the coronary sinus. *Correspondence to: Parag Barwad, Department of Cardiology, Advanced Cardiac Centre, Post Graduate Institute of Medical Education & Research, Chandigarh-160012, India, Tel: +91 8968732470, E-mail: paragaims@gmail.com