{"title":"在粘土和其他材料中安装吸力沉箱的设计程序","authors":"G. Houlsby, B. Byrne","doi":"10.1680/GENG.2005.158.2.75","DOIUrl":null,"url":null,"abstract":"Suction-installed skirted foundations, often referred to as suction caissons, are increasingly being used for a variety of offshore applications. In designing a caisson a geotechnical engineer must consider the installation process as well as the in-place performance. The purpose of this paper is to present calculation procedures for the installation of a caisson in clay. For clay sites, the caisson will often be used as an anchor, with the ratio of the skirt length (L) to the diameter (D) as high as 5. Calculation methods are presented for determining the resistance to penetration of open-ended cylindrical caisson foundations with and without the application of suction inside the caisson. Comparisons between predictions and case records are made. A companion paper describes the calculation procedure for installation in sand soils. Finally, comments are made here about installation in a variety of soils other than homogeneous deposits of clay or sand.","PeriodicalId":45150,"journal":{"name":"Geotechnical Engineering","volume":null,"pages":null},"PeriodicalIF":0.3000,"publicationDate":"2005-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1680/GENG.2005.158.2.75","citationCount":"112","resultStr":"{\"title\":\"Design procedures for installation of suction caissons in clay and other materials\",\"authors\":\"G. Houlsby, B. Byrne\",\"doi\":\"10.1680/GENG.2005.158.2.75\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Suction-installed skirted foundations, often referred to as suction caissons, are increasingly being used for a variety of offshore applications. In designing a caisson a geotechnical engineer must consider the installation process as well as the in-place performance. The purpose of this paper is to present calculation procedures for the installation of a caisson in clay. For clay sites, the caisson will often be used as an anchor, with the ratio of the skirt length (L) to the diameter (D) as high as 5. Calculation methods are presented for determining the resistance to penetration of open-ended cylindrical caisson foundations with and without the application of suction inside the caisson. Comparisons between predictions and case records are made. A companion paper describes the calculation procedure for installation in sand soils. Finally, comments are made here about installation in a variety of soils other than homogeneous deposits of clay or sand.\",\"PeriodicalId\":45150,\"journal\":{\"name\":\"Geotechnical Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.3000,\"publicationDate\":\"2005-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1680/GENG.2005.158.2.75\",\"citationCount\":\"112\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Geotechnical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1680/GENG.2005.158.2.75\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, GEOLOGICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Geotechnical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1680/GENG.2005.158.2.75","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, GEOLOGICAL","Score":null,"Total":0}
Design procedures for installation of suction caissons in clay and other materials
Suction-installed skirted foundations, often referred to as suction caissons, are increasingly being used for a variety of offshore applications. In designing a caisson a geotechnical engineer must consider the installation process as well as the in-place performance. The purpose of this paper is to present calculation procedures for the installation of a caisson in clay. For clay sites, the caisson will often be used as an anchor, with the ratio of the skirt length (L) to the diameter (D) as high as 5. Calculation methods are presented for determining the resistance to penetration of open-ended cylindrical caisson foundations with and without the application of suction inside the caisson. Comparisons between predictions and case records are made. A companion paper describes the calculation procedure for installation in sand soils. Finally, comments are made here about installation in a variety of soils other than homogeneous deposits of clay or sand.
期刊介绍:
The objectives of the Association shall be the promotion of co-operation among geotechnical societies in SE Asia; and the assistance to member societies who have limited number of members. Now there is only one combined web titled: AGSSEA-SEAGS. SEAGS & AGSSEA encourage the submission of scholarly and practice-oriented articles to its journal. The journal is published quarterly. Both sponsors of the journal, the Southeast Asian Geotechnical Society and the Association of Geotechnical Societies in Southeast Asia, promote the ideals and goals of the International Society of Soil Mechanics and Geotechhnical Engineering in fostering communications, developing insights and enabling the advancement of the geotechnical engineering discipline.