评估不同灌溉方案对灌溉液渗入模拟侧管的影响(体外研究)。

IF 1.6 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
European Endodontic Journal Pub Date : 2024-03-08 Epub Date: 2024-01-12 DOI:10.14744/eej.2023.29494
Ahmed Qasim Talib, Hussain F Al-Huwaizi
{"title":"评估不同灌溉方案对灌溉液渗入模拟侧管的影响(体外研究)。","authors":"Ahmed Qasim Talib, Hussain F Al-Huwaizi","doi":"10.14744/eej.2023.29494","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To compare the effectiveness of lateral canal irrigation penetration by conventional needle, passive ultrasonic, sonic endo activator, and Erbium laser (2780nm).</p><p><strong>Methods: </strong>A total of 40 palatal roots of human maxillary first molars were collected and instrumented at a working length of 12 mm by an X1-X4 rotary Protaper Next system (Dentsply, Maillefer, Ballaigues, Switzerland) using the crown-down technique. Artificial lateral canals were made at 2, 4, and 6 mm from the apex on mesial and distal sides using an ISO rotary reamer (Dentsply, Maillefer, Ballaigues, Switzerland; #10 for mesial, #08 for distal). The samples were then cleared using methyl salicylate. A solution of black ink and normal saline was used as an irrigant for the root canal. The percentages of the penetration of the ink into the lateral canals were measured using a stereomicroscope (Q-Scope, Arnhem, The Netherlands) with the aid of program Image J. The Tukey test is used to assess the significant difference between intragroup and intergroup comparisons of different thirds, and the T-test is used to assess the significant difference between every two groups and for the mesial and distal sides of each group. The level of significance was set at 0.05.</p><p><strong>Results: </strong>Results showed that none of the activation techniques used resulted in complete lateral canal penetrations; however, on both sides at all thirds, the Erbium laser (2780 nm) achieved the highest results with a highly significant statistical difference (p=0.05) with all other groups, and the least penetration was in the conventional needle group.</p><p><strong>Conclusion: </strong>The size of the lateral canal is a restricting factor for all activation methods; the best results can be achieved by laser. Conventional needles cannot be used alone to disinfect complex canal anatomy; however, passive ultrasonic and sonic endo activator activations can produce comparable results.</p>","PeriodicalId":11860,"journal":{"name":"European Endodontic Journal","volume":"1 1","pages":"146 - 153"},"PeriodicalIF":1.6000,"publicationDate":"2024-03-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10938356/pdf/","citationCount":"0","resultStr":"{\"title\":\"Assessment of the Effect of Different Irrigation Protocols on the Penetration of Irrigation Solution into Simulated Lateral Canals (In Vitro Study).\",\"authors\":\"Ahmed Qasim Talib, Hussain F Al-Huwaizi\",\"doi\":\"10.14744/eej.2023.29494\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To compare the effectiveness of lateral canal irrigation penetration by conventional needle, passive ultrasonic, sonic endo activator, and Erbium laser (2780nm).</p><p><strong>Methods: </strong>A total of 40 palatal roots of human maxillary first molars were collected and instrumented at a working length of 12 mm by an X1-X4 rotary Protaper Next system (Dentsply, Maillefer, Ballaigues, Switzerland) using the crown-down technique. Artificial lateral canals were made at 2, 4, and 6 mm from the apex on mesial and distal sides using an ISO rotary reamer (Dentsply, Maillefer, Ballaigues, Switzerland; #10 for mesial, #08 for distal). The samples were then cleared using methyl salicylate. A solution of black ink and normal saline was used as an irrigant for the root canal. The percentages of the penetration of the ink into the lateral canals were measured using a stereomicroscope (Q-Scope, Arnhem, The Netherlands) with the aid of program Image J. The Tukey test is used to assess the significant difference between intragroup and intergroup comparisons of different thirds, and the T-test is used to assess the significant difference between every two groups and for the mesial and distal sides of each group. The level of significance was set at 0.05.</p><p><strong>Results: </strong>Results showed that none of the activation techniques used resulted in complete lateral canal penetrations; however, on both sides at all thirds, the Erbium laser (2780 nm) achieved the highest results with a highly significant statistical difference (p=0.05) with all other groups, and the least penetration was in the conventional needle group.</p><p><strong>Conclusion: </strong>The size of the lateral canal is a restricting factor for all activation methods; the best results can be achieved by laser. Conventional needles cannot be used alone to disinfect complex canal anatomy; however, passive ultrasonic and sonic endo activator activations can produce comparable results.</p>\",\"PeriodicalId\":11860,\"journal\":{\"name\":\"European Endodontic Journal\",\"volume\":\"1 1\",\"pages\":\"146 - 153\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-03-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10938356/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Endodontic Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14744/eej.2023.29494\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/12 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Endodontic Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14744/eej.2023.29494","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/12 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:比较传统针、被动超声波、声波内科激活器和铒激光(2780nm)的侧管灌注穿透效果:比较传统针、被动超声波、声波内充填器和铒激光(2780nm)进行侧根管灌注渗透的效果:收集人类上颌第一磨牙的腭根共 40 个,使用 X1-X4 旋转 Protaper Next 系统(Dentsply, Maillefer, Ballaigues, Switzerland),采用牙冠向下技术对工作长度为 12 毫米的根进行器械操作。使用 ISO 旋转铰刀(Dentsply,Maillefer,Ballaigues,瑞士;10 号用于中侧,08 号用于远侧)在中侧和远侧距离根尖 2、4 和 6 毫米处制作人工侧根管。然后用水杨酸甲酯清除样本。使用黑色墨水和生理盐水溶液作为根管冲洗剂。使用体视显微镜(Q-Scope,荷兰阿纳姆)并借助 Image J 程序测量墨水渗入侧根管的百分比。Tukey 检验用于评估不同三度根管的组内比较和组间比较之间的显著差异,T 检验用于评估每两组之间以及每组的中侧和远侧之间的显著差异。显著性水平定为 0.05:结果表明,所使用的激活技术均未完全穿透侧管;然而,在两侧的所有三度,铒激光(2780 nm)的效果最好,与所有其他组相比具有非常显著的统计学差异(P=0.05),而传统针组的穿透力最小:结论:侧管的大小是所有激活方法的限制因素;激光可达到最佳效果。传统针不能单独用于消毒复杂的牙管解剖结构;然而,被动超声波和声波牙内管激活器可以产生相当的效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Assessment of the Effect of Different Irrigation Protocols on the Penetration of Irrigation Solution into Simulated Lateral Canals (In Vitro Study).

Objective: To compare the effectiveness of lateral canal irrigation penetration by conventional needle, passive ultrasonic, sonic endo activator, and Erbium laser (2780nm).

Methods: A total of 40 palatal roots of human maxillary first molars were collected and instrumented at a working length of 12 mm by an X1-X4 rotary Protaper Next system (Dentsply, Maillefer, Ballaigues, Switzerland) using the crown-down technique. Artificial lateral canals were made at 2, 4, and 6 mm from the apex on mesial and distal sides using an ISO rotary reamer (Dentsply, Maillefer, Ballaigues, Switzerland; #10 for mesial, #08 for distal). The samples were then cleared using methyl salicylate. A solution of black ink and normal saline was used as an irrigant for the root canal. The percentages of the penetration of the ink into the lateral canals were measured using a stereomicroscope (Q-Scope, Arnhem, The Netherlands) with the aid of program Image J. The Tukey test is used to assess the significant difference between intragroup and intergroup comparisons of different thirds, and the T-test is used to assess the significant difference between every two groups and for the mesial and distal sides of each group. The level of significance was set at 0.05.

Results: Results showed that none of the activation techniques used resulted in complete lateral canal penetrations; however, on both sides at all thirds, the Erbium laser (2780 nm) achieved the highest results with a highly significant statistical difference (p=0.05) with all other groups, and the least penetration was in the conventional needle group.

Conclusion: The size of the lateral canal is a restricting factor for all activation methods; the best results can be achieved by laser. Conventional needles cannot be used alone to disinfect complex canal anatomy; however, passive ultrasonic and sonic endo activator activations can produce comparable results.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
European Endodontic Journal
European Endodontic Journal DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.40
自引率
5.60%
发文量
25
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信