Hyunhee Bang, Hoseob Song, Chul-woo Park, Ilhyung Park, M. Kim, S. Joung
{"title":"针形对不同植发器插入力的影响","authors":"Hyunhee Bang, Hoseob Song, Chul-woo Park, Ilhyung Park, M. Kim, S. Joung","doi":"10.14326/ABE.10.90","DOIUrl":null,"url":null,"abstract":"Surgeons insert approximately 3000 hair implants in a single hair restoration surgery, and the needle shape critically affects surgical performance including surgical time, survival rate, and the surgeon ʼ s fatigue. There are several experimental studies on the relationship between needle shape and performance; however, there are no studies on hair implant needles, which are different from other medical needles as they have a com-paratively short bevel. This study compared several hair implant needles to determine the relationship between needle shape and insertion force. Eight hair implant needles with the same diameter were collected, and their geometrical data were visually measured. The insertion force and total work of each needle were measured using custom-made force measurement equipment; the results were statistically compared, and their correlation was analyzed. Moreover, a qualitative comparison was made. The needle insertion force ranged from 1.30 to 2.97 N, and the total work ranged from 8.15 to 10.97 mJ. The primary bevel and acute angles showed a moderate positive correlation with the total work. A longer point length, smaller primary bevel, and acute angle decrease the total work of hair implant needles. As per the results of the qualitative comparison, we found that the surgeons can identify the differences in needle insertion force among various hair implant needles, and their grading was consistent with the grading according to the total work of needle insertion.","PeriodicalId":54017,"journal":{"name":"Advanced Biomedical Engineering","volume":"1 1","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of Needle Geometry on Insertion Force of Different Hair Implanters\",\"authors\":\"Hyunhee Bang, Hoseob Song, Chul-woo Park, Ilhyung Park, M. Kim, S. Joung\",\"doi\":\"10.14326/ABE.10.90\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Surgeons insert approximately 3000 hair implants in a single hair restoration surgery, and the needle shape critically affects surgical performance including surgical time, survival rate, and the surgeon ʼ s fatigue. There are several experimental studies on the relationship between needle shape and performance; however, there are no studies on hair implant needles, which are different from other medical needles as they have a com-paratively short bevel. This study compared several hair implant needles to determine the relationship between needle shape and insertion force. Eight hair implant needles with the same diameter were collected, and their geometrical data were visually measured. The insertion force and total work of each needle were measured using custom-made force measurement equipment; the results were statistically compared, and their correlation was analyzed. Moreover, a qualitative comparison was made. The needle insertion force ranged from 1.30 to 2.97 N, and the total work ranged from 8.15 to 10.97 mJ. The primary bevel and acute angles showed a moderate positive correlation with the total work. A longer point length, smaller primary bevel, and acute angle decrease the total work of hair implant needles. As per the results of the qualitative comparison, we found that the surgeons can identify the differences in needle insertion force among various hair implant needles, and their grading was consistent with the grading according to the total work of needle insertion.\",\"PeriodicalId\":54017,\"journal\":{\"name\":\"Advanced Biomedical Engineering\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2021-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advanced Biomedical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14326/ABE.10.90\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advanced Biomedical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14326/ABE.10.90","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

外科医生在一次头发修复手术中植入大约3000根头发,针的形状严重影响手术效果,包括手术时间、存活率和外科医生的疲劳程度。关于针形与性能关系的实验研究较多;然而,植发针与其他医用针不同的是,植发针的斜角相对较短,目前还没有关于植发针的研究。本研究比较了几种植发针,以确定针的形状和插入力之间的关系。收集直径相同的植发针8根,目测其几何数据。采用特制的测力设备测量每根针的插入力和总功;对结果进行统计学比较,并分析其相关性。并进行了定性比较。针入力范围为1.30 ~ 2.97 N,总功范围为8.15 ~ 10.97 mJ。初级斜角和锐角与总功呈中等正相关。较长的针头长度,较小的初级斜角和锐角减少了植发针的总功。从定性比较的结果来看,我们发现外科医生能够识别出各种植发针的插针力的差异,他们的评分与根据插针总功的评分是一致的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effect of Needle Geometry on Insertion Force of Different Hair Implanters
Surgeons insert approximately 3000 hair implants in a single hair restoration surgery, and the needle shape critically affects surgical performance including surgical time, survival rate, and the surgeon ʼ s fatigue. There are several experimental studies on the relationship between needle shape and performance; however, there are no studies on hair implant needles, which are different from other medical needles as they have a com-paratively short bevel. This study compared several hair implant needles to determine the relationship between needle shape and insertion force. Eight hair implant needles with the same diameter were collected, and their geometrical data were visually measured. The insertion force and total work of each needle were measured using custom-made force measurement equipment; the results were statistically compared, and their correlation was analyzed. Moreover, a qualitative comparison was made. The needle insertion force ranged from 1.30 to 2.97 N, and the total work ranged from 8.15 to 10.97 mJ. The primary bevel and acute angles showed a moderate positive correlation with the total work. A longer point length, smaller primary bevel, and acute angle decrease the total work of hair implant needles. As per the results of the qualitative comparison, we found that the surgeons can identify the differences in needle insertion force among various hair implant needles, and their grading was consistent with the grading according to the total work of needle insertion.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Advanced Biomedical Engineering
Advanced Biomedical Engineering ENGINEERING, BIOMEDICAL-
CiteScore
1.40
自引率
10.00%
发文量
15
审稿时长
15 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信