{"title":"基于有限元概念的人工髋关节髋臼构件材料选择","authors":"M. Kalayarasan, L. Prakash, Subramaniam Shankar","doi":"10.1504/IJECB.2013.056519","DOIUrl":null,"url":null,"abstract":"Hip joint replacement is an important issue in orthopaedic surgery. The success of the artificial hip replacement depends upon proper material selection, structure and shape of the prosthesis. Many orthopaedic analyses have been tried with different materials, but ended with partial success on the application side. The main objective of this paper is to extend the acetabular component finite element model of human hip prosthesis to investigate the maximum von Mises stress, contact pressure, contact radius and mean contact pressure to yield strength ratio for different combinations of bio-compatible materials. Eight different geometrical parameters are considered in the current study. The materials used are Co-Cr alloy, Co-Cr-Mo alloy, ultra high molecular weight polyethylene (UHMWPE) and alumina. To guarantee good clinical results in total hip replacement (THR), it is predicted from this extensive analysis that cobalt chromium paired with UHMWPE provides optimum performance in all the conditions. The analysis demonstrates that the implant with larger head radius, cup radius, and UHMWPE cup thickness with decrease in radial clearance value yields better mechanical performance. The finite element results are also compared with the experimental data of Jin et al. (1999) and found to be in good agreement with each other.","PeriodicalId":90184,"journal":{"name":"International journal of experimental and computational biomechanics","volume":"2 1","pages":"118"},"PeriodicalIF":0.0000,"publicationDate":"2013-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1504/IJECB.2013.056519","citationCount":"13","resultStr":"{\"title\":\"Material selection of acetabular component in human hip prosthesis using finite element concepts\",\"authors\":\"M. Kalayarasan, L. Prakash, Subramaniam Shankar\",\"doi\":\"10.1504/IJECB.2013.056519\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Hip joint replacement is an important issue in orthopaedic surgery. The success of the artificial hip replacement depends upon proper material selection, structure and shape of the prosthesis. Many orthopaedic analyses have been tried with different materials, but ended with partial success on the application side. The main objective of this paper is to extend the acetabular component finite element model of human hip prosthesis to investigate the maximum von Mises stress, contact pressure, contact radius and mean contact pressure to yield strength ratio for different combinations of bio-compatible materials. Eight different geometrical parameters are considered in the current study. The materials used are Co-Cr alloy, Co-Cr-Mo alloy, ultra high molecular weight polyethylene (UHMWPE) and alumina. To guarantee good clinical results in total hip replacement (THR), it is predicted from this extensive analysis that cobalt chromium paired with UHMWPE provides optimum performance in all the conditions. The analysis demonstrates that the implant with larger head radius, cup radius, and UHMWPE cup thickness with decrease in radial clearance value yields better mechanical performance. The finite element results are also compared with the experimental data of Jin et al. (1999) and found to be in good agreement with each other.\",\"PeriodicalId\":90184,\"journal\":{\"name\":\"International journal of experimental and computational biomechanics\",\"volume\":\"2 1\",\"pages\":\"118\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-09-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1504/IJECB.2013.056519\",\"citationCount\":\"13\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International journal of experimental and computational biomechanics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1504/IJECB.2013.056519\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of experimental and computational biomechanics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1504/IJECB.2013.056519","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

摘要

髋关节置换术是骨科手术中的一个重要课题。人工髋关节置换术的成功与否取决于人工髋关节的材料选择、结构和形状。许多骨科分析已经尝试了不同的材料,但在应用方面只取得了部分成功。本文的主要目的是扩展人体髋关节假体髋臼构件有限元模型,研究不同生物相容性材料组合下的最大von Mises应力、接触压力、接触半径和平均接触压力与屈服强度比。本研究考虑了八种不同的几何参数。使用的材料有Co-Cr合金、Co-Cr- mo合金、超高分子量聚乙烯(UHMWPE)和氧化铝。为了保证全髋关节置换术(THR)的良好临床效果,从这一广泛的分析中预测,钴铬与UHMWPE配对在所有条件下都能提供最佳性能。分析表明,种植体的头半径、杯半径和超高分子量聚乙烯杯厚度越大,径向间隙值越小,其力学性能越好。将有限元计算结果与Jin et al.(1999)的实验数据进行了比较,两者吻合较好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Material selection of acetabular component in human hip prosthesis using finite element concepts
Hip joint replacement is an important issue in orthopaedic surgery. The success of the artificial hip replacement depends upon proper material selection, structure and shape of the prosthesis. Many orthopaedic analyses have been tried with different materials, but ended with partial success on the application side. The main objective of this paper is to extend the acetabular component finite element model of human hip prosthesis to investigate the maximum von Mises stress, contact pressure, contact radius and mean contact pressure to yield strength ratio for different combinations of bio-compatible materials. Eight different geometrical parameters are considered in the current study. The materials used are Co-Cr alloy, Co-Cr-Mo alloy, ultra high molecular weight polyethylene (UHMWPE) and alumina. To guarantee good clinical results in total hip replacement (THR), it is predicted from this extensive analysis that cobalt chromium paired with UHMWPE provides optimum performance in all the conditions. The analysis demonstrates that the implant with larger head radius, cup radius, and UHMWPE cup thickness with decrease in radial clearance value yields better mechanical performance. The finite element results are also compared with the experimental data of Jin et al. (1999) and found to be in good agreement with each other.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信